Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
2.
Heart Rhythm O2 ; 2(6Part A): 588-596, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34988503

ABSTRACT

BACKGROUND: Quadripolar left ventricular (LV) leads are capable of sensing and pacing the left ventricle from 4 different electrodes, which may potentially improve patient response to cardiac resynchronization therapy (CRT). OBJECTIVE: We measured 3 different time intervals: right ventricular (RV)-sensed to LV-sensed during intrinsic rhythm (RVs-LVs), RV-paced to LV-sensed (RVp-LVs), and LV-paced to LV-sensed (LVp-LVs, between distal [LV1] and proximal pole on a quadripolar LV lead), and assessed their association with CRT response in terms of LV end-systolic volume (LVESV) and a composite benefit index (CBI) comprising LVESV, LV ejection fraction (LVEF), brain natriuretic peptide level, and NYHA class. METHODS: A CRT-defibrillator system with quadripolar LV lead was implanted in 196 patients (mean age 69 years, mean LVEF 30%, left bundle-branch block [LBBB] 58%). Conduction intervals were measured before hospital discharge. At baseline and 7-month follow-up, echocardiographic and other components of CBI were determined. RESULTS: The mean RVs-LV1s, RVp-LV1s, and LVp-LVs delays were 68 ± 38 ms, 132 ± 34 ms, and 99 ± 31 ms, respectively. From baseline to 7 months, LVESV decreased by 17.3% ± 28.6%. The RVs-LV1s interval correlated stronger with CBI (R2 = 0.12, P < .00001) than with LVESV change (R2 = 0.05, P = .006). In contrast, RVp-LV1s did not correlate and LVp-LVs correlated only weakly with CRT response. The subgroup of patients (44%) with LBBB and RVs-LV1s above the lower quartile (≥34 ms) showed the greatest response to CRT. CONCLUSION: The RVs-LVs interval during intrinsic rhythm is relevant for CRT success, whereas RVp-LVs and LVp-LVs intervals did not predict CRT response.

3.
J Cardiol ; 77(3): 263-270, 2021 03.
Article in English | MEDLINE | ID: mdl-33011056

ABSTRACT

BACKGROUND: Catheter ablation (CA) is an important strategy for managing atrial fibrillation (AF). However, long-term anticoagulation strategies and clinical outcomes following CA, including thromboembolism and bleeding, have not yet been elucidated. METHODS: We established a prospective registry, called the JACRE registry, for patients on rivaroxaban or warfarin administration who received CA for AF. The outcomes up to 30 days following the procedure were reported previously. The present study involved longer follow-up of patients enrolled in this registry to evaluate long-term anticoagulation strategies and clinical outcomes. RESULTS: Data of 975 patients (rivaroxaban, n = 823; warfarin, n = 152) were collected from 27 institutes. Patient population had mean age 63.7 ± 10.3 years, 710 (72.8%) males, mean CHA2DS2-VASc score 1.9 ± 1.5, and mean follow-up period 28.7 ± 12.7 months after the index procedure. Anticoagulants were continued in 496 (50.9%) patients during the follow-up. Thromboembolism occurred in 3 patients, hemorrhagic stroke in 5, and major bleeding events in 9 (annualized event rate, 0.13%, 0.22%, and 0.40% per patient-year, respectively). There were no differences in the composite event rate of thromboembolism and International Society on Thrombosis and Haemostasis major bleeding between rivaroxaban and warfarin cohorts (0.53% and 0.55% per patient-year, respectively). CONCLUSIONS: Long-term incidence of thromboembolism was extremely low in patients with AF treated with CA, while that of major bleeding was not especially low. Clinical Trials Registry: UMIN000032829 / UMIN000032830.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Stroke , Administration, Oral , Aged , Anticoagulants/adverse effects , Atrial Fibrillation/drug therapy , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Humans , Male , Middle Aged , Registries , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Treatment Outcome , Warfarin/adverse effects
4.
Intern Med ; 60(5): 755-759, 2021 Mar 01.
Article in English | MEDLINE | ID: mdl-33028772

ABSTRACT

Keishibukuryogan is a Kampo medicine that induces vasodilation and improves the blood flow velocity in subcutaneous blood vessels. We herein report two cases in which keishibukuryogan completely diminished subcutaneous hematoma after cardiac resynchronization therapy pacemaker implantation and defibrillator battery replacement within a month. Keishibukuryogan can be a good option for treating or preventing subcutaneous hematoma after surgical procedures for devices.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Drugs, Chinese Herbal , Pacemaker, Artificial , Defibrillators, Implantable/adverse effects , Hematoma/diagnostic imaging , Hematoma/etiology , Humans , Pacemaker, Artificial/adverse effects
5.
Intern Med ; 58(23): 3421-3425, 2019 Dec 01.
Article in English | MEDLINE | ID: mdl-31391395

ABSTRACT

Cryoballoon ablation is a well-established therapeutic tool for paroxysmal atrial fibrillation (PAF). We herein report a rare case of a 69-year-old man with PAF undergoing hemodialysis due to chronic kidney disease who developed hyperkalemia caused by possible cold agglutinin disease during cryoballoon ablation therapy. During the procedure, his electrocardiogram showed wide QRS when we finished cryoablation therapy. We detected hyperkalemia and performed urgent hemodialysis. We should bear in mind that cold agglutinin disease can occur during cryoballoon ablation.


Subject(s)
Anemia, Hemolytic, Autoimmune/etiology , Cryosurgery/adverse effects , Hyperkalemia/etiology , Aged , Atrial Fibrillation/surgery , Cryosurgery/methods , Electrocardiography , Humans , Male , Pulmonary Veins/surgery , Treatment Outcome
6.
J Arrhythm ; 35(3): 554-557, 2019 Jun.
Article in English | MEDLINE | ID: mdl-31293708

ABSTRACT

Of 3577 patients with supraventricular arrhythmias, 3 demonstrated an atresia of the coronary sinus (CS) ostium. Two patients had the accessory pathways. One had atrial fibrillation. No unroofed CS or apparent persistent left superior vena cava was observed. Venous drainage through a small cardiac vein located on the lateral portion of the tricuspid annulus was observed in all patients. Those cases demonstrated that the incidence of ostial atresia of the CS was 0.084%. Accessory pathways were often accompanied by this anomaly. An abnormal venous orifice located on the lateral tricuspid annulus often functioned as the drainage of the CS flow.

7.
J Cardiovasc Electrophysiol ; 30(6): 844-853, 2019 06.
Article in English | MEDLINE | ID: mdl-30802332

ABSTRACT

INTRODUCTION: Pulmonary vein isolation (PVI) is widely performed for atrial fibrillation (AFib). However, it is insufficient to maintain sinus rhythm (SR) in persistent and long persistent atrial fibrillation (Per-AFib). Ablation of complex fractionated atrial electrograms (CFAEs) is currently classified as class IIb, However, the concept of length of potential was different between the current CFAE module of CARTO system and the definition of CFAE potential. The current CFAE module was configured in the shortest complex interval (SCI) mode, in which the meaning of length of potential was the interval of each component of fragmented potentials. That was a part of the potential. On the other hand, the meaning of the definition of CFAE potential was the length of fragmented potential itself. The purpose of this study was to essentially evaluate fragmented potentials by revisiting in interval confidence level (ICL) mode and express them on the map and prospectively investigate the efficacy and prognosis of a new tailored approach for defragmentation, which is called early area defragmentation (EADF). METHODS AND RESULTS: We acquired atrial potentials by modified CFAE module in ICL mode (K-CFAE potential) and visualized the distribution of K-CFAE potential (K-CFAE map). We performed PVI, and we ablated the fragmented areas based on the K-CFAE map. We enrolled 77 patients in this study (control group: 84 patients). After 24-month follow-up, 75.3% were able to maintain SR. CONCLUSIONS: K-CFAE mapping faithfully represented the distribution of fragmented areas. PVI, together with our new tailored approach, EADF, was successful in treating Per-AFib.


Subject(s)
Action Potentials , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Heart Rate , Pulmonary Veins/surgery , Aged , Atrial Fibrillation/physiopathology , Case-Control Studies , Catheter Ablation/adverse effects , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Pulmonary Veins/physiopathology , Recurrence , Signal Processing, Computer-Assisted , Time Factors , Treatment Outcome
8.
J Cardiol ; 72(4): 316-320, 2018 10.
Article in English | MEDLINE | ID: mdl-29705082

ABSTRACT

BACKGROUND: Optimal management of advisory implantable cardioverter defibrillator (ICD) leads has not been established. Several studies were reported concerning the lead extraction of advisory ICD leads, but the implant duration of those studies was short. We estimated the efficacy of lead extractions of advisory ICD leads with a relatively longer duration in Japanese patients. METHODS: We retrospectively analyzed 28 patients who underwent a lead extraction at Kokura Memorial Hospital and Tokyo Medical and Dental University Hospital [Fidelis (Medtronic, Minneapolis, MN, USA): n=19, Riata (St. Jude Medical, Sylmar, CA, USA): n=8, Isoline (SORIN CRM SAS, Clamart, France): n=1]. The mean implant duration was 63.3±19.3 months. The indications were device related infections in 3, electrical lead failures in 18, electrical lead failures and venous obstructions in 3, and prophylactic reasons in 4 patients. Inappropriate shocks because of electrical lead failures were observed in 9 patients. RESULTS: Complete removals were achieved of all 28 advisory leads. In 23 out of 28 patients, new ICD leads were implanted during the same procedure. In one patient, open chest surgery was performed for a hemothorax that occurred during a new ICD lead implantation just after successfully removing the advisory ICD lead. There were no other major or minor complications. CONCLUSION: Transvenous extractions of advisory ICD leads with relatively long implant duration were performed with a high success rate and low complication and mortality rate in Japanese patients.


Subject(s)
Defibrillators, Implantable/adverse effects , Device Removal/methods , Aged , Female , Humans , Male , Middle Aged , Operative Time , Retrospective Studies , Time Factors , Tokyo , Treatment Outcome
9.
J Cardiol ; 70(5): 411-415, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28454777

ABSTRACT

BACKGROUND: The causative organism in cardiovascular implantable electronic device (CIED) infection is usually diagnosed with the cultures from blood, removed leads, and/or infected pocket material. The cultured organism, however, is sometimes different among these samples. METHODS: Two hundred sixty patients with CIED infection, who underwent lead extraction between April 2005 and December 2014, were analyzed. More than two blood culture sets, all the extracted leads, and swab culture of the pocket were sent to the laboratory for culture. Among the patients all of whose microbiological examinations were available, we analyzed the causative organism defined as the species detected in at least two different sites. RESULTS: All the culture results were available in the 208 patients, showing 69 systemic infections (including 30 cases of infectious endocarditis) and 139 local infections. Blood culture, lead culture, and swab culture were positive in 57 (27%), 169 (81%), and 152 (73%), respectively. Staphylococcus aureus [37% including methicillin-resistant S. aureus (MRSA) (12%)] and coagulase-negative staphylococci (CoNS, 36%) were the most common causative organism, followed by non-staphylococci (23%), and poly-microbial infection (4%). The detection of S. aureus from pocket or removed leads rendered higher predictive value of a causative organism than that of CoNS. The detection of Gram-negative bacteria, fungi, and mycobacteria indicated that it was most likely a causative organism. Gram-positive bacteria excluding Staphylococcus, such as Corynebacterium spp., tended to coexist as a benign organism. CONCLUSIONS: The causative organism is mostly S. aureus and CoNS. Detection of S. aureus or Gram-negative bacteria means that it is more likely a causative organism.


Subject(s)
Bacteria/isolation & purification , Defibrillators, Implantable/microbiology , Fungi/isolation & purification , Pacemaker, Artificial/microbiology , Prosthesis-Related Infections/microbiology , Aged , Aged, 80 and over , Bacterial Infections/blood , Bacterial Infections/microbiology , Defibrillators, Implantable/adverse effects , Female , Humans , Male , Middle Aged , Mycoses/blood , Mycoses/microbiology , Pacemaker, Artificial/adverse effects
10.
J Arrhythm ; 32(6): 462-467, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27920830

ABSTRACT

BACKGROUND: Catheter ablation can reduce episodes of ventricular tachycardia (VT) after myocardial infarction (MI). However, the optimal endpoint of the ablation procedure remains unclear. METHODS: Fifty-one consecutive patients who received catheter ablation for VT after MI were included. The procedures targeted the isthmus of all the induced, sustained VTs. When the patients with induced VTs were hemodynamically stable, radiofrequency energy was delivered at the mid-diastolic potential recording site during VT. When the patients with VTs were hemodynamically unstable, the critical channel was identified at the delayed potential recording site, showing a good pace map, with a long stimulus-QRS interval. We delivered radiofrequency energy along the identified isthmus and across the exit of the circuit. RESULTS: At the end of the procedure, all VTs became non-inducible in 30 patients (59%) and some VTs were inducible in 21 patients (41%). During a mean of 40±29 months of follow-up, no VT or ventricular fibrillation recurred in 24 patients (80%) in the non-inducible group and in 12 patients (57%) in the inducible group, respectively (P=0.03). The identification of the channel during VT mapping tended to associate with no recurrence, although the difference was not statistically significant (P=0.2). Fourteen patients (27%) died during the follow-up period, mostly due to non-cardiac causes. CONCLUSIONS: The catheter ablation targeting the isthmus of prior-MIVT and non-inducibility at the end of the procedure can provide a satisfactory follow-up result.

11.
J Arrhythm ; 32(4): 308-12, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27588155

ABSTRACT

BACKGROUND: Lead extraction using laser sheaths is performed mainly for cardiac implantable electronic device (CIED) infections. However, there are few reports concerning the management of CIED infections in Japan. METHODS AND RESULTS: Lead extraction procedures were performed in 183 patients targeting 450 leads (atrial leads: 170, ventricular: 181, implantable cardioverter-defibrillators (ICDs): 79, and coronary sinus: 20). One hundred twenty patients (65.6%) presented with pocket infections without the presentation of an endovascular infection. Blood cultures were positive at least once in 63 patients (34.4%). Complete procedure success was achieved for 437 leads (97.1%) while partial removal occurred in nine, and failure in four leads. Major complications directly related to the procedure occurred in five patients (2.7%). Two of the four patients with a cardiac tamponade required a surgical repair. All patients received intravenous antibiotics, at least, one week after the procedure. Pocket or systemic infections were successfully controlled in 181 patients (98.9%). Coagulase-negative staphylococci (30.1%) and Staphylococcus aureus (37.1%) were the most common causes of CIED infections. CONCLUSION: The current status of CIED infections in Japan seems to be similar to that previously reported from foreign countries. The optimal treatment of CIED infections involves the complete explantation of all hardware, followed by antibiotic therapy.

12.
Circ J ; 80(4): 887-94, 2016.
Article in English | MEDLINE | ID: mdl-26936115

ABSTRACT

BACKGROUND: The clinical efficacy of catheter ablation (CA) for paroxysmal atrial fibrillation (PAF) in patients with sick sinus syndrome (SSS) and the mechanism and predictors of recurrence are not yet completely elucidated. METHODS AND RESULTS: Of 963 consecutive patients who underwent PAF ablation during the study period, a total of 108 patients with SSS (SSS group) and 108 matched controls without SSS (non-SSS group) were followed up. During the follow-up period (mean, 32.8±17.5 months), the SSS group had significantly higher AF recurrence rate since the last procedure than the non-SSS group (26.9% vs. 12.0%; P=0.02). The SSS group had significantly higher prevalence of non-pulmonary vein (non-PV) foci than the non-SSS group (25.9% vs. 13.9%; P=0.027). On multivariate analysis congestive heart failure (HR, 13.7; 95% CI: 1.57-119; P=0.02) and non-PV foci (HR, 5.75; 95% CI: 1.69-19.6; P=0.005) were independent predictors of recurrence following CA in the SSS group. In the SSS group, 88 patients had bradycardia-tachycardia syndrome without prior permanent pacemaker implantation. Of these, 6 required pacemaker implantation because of AF and sinus pause recurrence. CONCLUSIONS: Patients with SSS are at higher risk of AF recurrence after CA. Non-PV foci are associated with AF recurrence following PAF with SSS.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Sick Sinus Syndrome , Aged , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Follow-Up Studies , Humans , Middle Aged , Recurrence , Risk Factors , Sick Sinus Syndrome/physiopathology , Sick Sinus Syndrome/surgery
13.
Heart Vessels ; 31(3): 402-7, 2016 Mar.
Article in English | MEDLINE | ID: mdl-25787020

ABSTRACT

Renin-angiotensin system (RAS) inhibitors may be useful in preventing the occurrence of paroxysmal atrial fibrillation (PAF). However, evaluation of such effect is difficult because many PAF episodes are asymptomatic and not all episodes are detected by intermittent electrocardiographic monitoring. A pacemaker has been developed with dedicated functions for AF detection and electrocardiogram storage. Accordingly, we examined the effect of losartan, an angiotensin receptor blocker on PAF occurrence using this new modality. We enrolled 70 consecutive patients who had undergone dual-chamber pacemaker implantation for sick sinus syndrome. Finally, 62 patients participated in the study. Thirty patients were randomized to the losartan group (mean 43 ± 12 mg/day) and 32 patients to the control group. They were followed up for 3 months. The frequency, the maximum duration and the total duration of PAF recorded by the stored electrocardiograms for the last 1 month during the observation period and study period were compared between the two groups. The change in the frequency of PAF from the observation period in the losartan and control groups was similar (-35 ± 25 vs. -67 ± 62 times; NS). However, the change in the maximum duration and the total duration of PAF was significantly shorter in the losartan group than in the control group (-493 ± 158 vs. -10 ± 69 min; p < 0.05, and -4007 ± 2334 vs. 1119 ± 714 min; p < 0.05, respectively). Losartan suppressed the maximum duration and the total duration of PAF in patients with sick sinus syndrome without hemodynamic changes. This is the first study to show the effect of a renin-angiotensin system inhibitor on the secondary prevention of PAF using the dedicated functions of a pacemaker for PAF detection and electrocardiogram storage.


Subject(s)
Angiotensin II Type 1 Receptor Blockers/therapeutic use , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/prevention & control , Biological Clocks/drug effects , Cardiac Pacing, Artificial , Losartan/therapeutic use , Pacemaker, Artificial , Sick Sinus Syndrome/therapy , Sinoatrial Node/drug effects , Aged , Angiotensin II Type 1 Receptor Blockers/adverse effects , Anti-Arrhythmia Agents/adverse effects , Atrial Fibrillation/diagnosis , Atrial Fibrillation/etiology , Atrial Fibrillation/physiopathology , Cardiac Pacing, Artificial/adverse effects , Electrocardiography/instrumentation , Equipment Design , Female , Humans , Japan , Losartan/adverse effects , Male , Predictive Value of Tests , Prospective Studies , Renin-Angiotensin System/drug effects , Secondary Prevention/instrumentation , Sick Sinus Syndrome/complications , Sick Sinus Syndrome/diagnosis , Sick Sinus Syndrome/physiopathology , Signal Processing, Computer-Assisted , Sinoatrial Node/physiopathology , Time Factors , Treatment Outcome
14.
Heart Rhythm ; 12(9): 1918-24, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25962801

ABSTRACT

BACKGROUND: Pulmonary vein (PV) isolation is an established treatment strategy for paroxysmal atrial fibrillation (PAF). However, the recurrence rate of PAF is 8% to 37%, despite repeated procedures, and the catheter ablation strategy for PAF with non-PV foci is unclear. OBJECTIVE: The purpose of this study was to assess the PAF ablation strategy for non-PV foci. METHODS: The study included 304 consecutive patients undergoing PAF ablation (209 males, age 63.0 ± 10.4 years) divided into 3 groups: group 1 (245 patients) with no inducible non-PV foci; group 2 (34 patients) with atrial fibrillation (AF) originating from non-PV foci and all the foci successfully ablated; and group 3 (25 patients) with AF originating from non-PV triggers, but without all foci being ablated or with persistently inducible AF. RESULTS: Mean follow-up period was 26.9 ± 11.8 months, and AF recurrence rates since the last procedure were 9.8%, 8.8%, and 68.0% in groups 1, 2, and 3, respectively. There was no statistically significant difference in recurrence rate between groups 1 and 2 (P = .89); however, there were statistically significant differences between groups 3 and 1 (P <.0001) and groups 3 and 2 (P <.0001). The patients in group 2 had an AF-free outcome to equivalent to those who had PV foci in group 1 (P = .83). CONCLUSION: Success rates can be improved for PAF ablation if non-PV foci are detected and eliminated.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Electrophysiologic Techniques, Cardiac/methods , Heart Conduction System/surgery , Pulmonary Veins/surgery , Tachycardia, Paroxysmal/surgery , Atrial Fibrillation/physiopathology , Female , Follow-Up Studies , Heart Conduction System/physiopathology , Heart Rate/physiology , Humans , Male , Middle Aged , Retrospective Studies , Tachycardia, Paroxysmal/physiopathology , Time Factors , Treatment Outcome
16.
Intern Med ; 52(12): 1347-52, 2013.
Article in English | MEDLINE | ID: mdl-23774545

ABSTRACT

Idiopathic left ventricular aneurysms and diverticula (LVA/Ds) are rare cardiac malformations that can be detected using certain imaging techniques. Although most patients with these malformations are clinically asymptomatic, some patients exhibit cardiac arrhythmias and other clinical manifestations. In electrophysiological studies, it is often difficult to establish the relationship between clinical manifestations of cardiac arrhythmias and those of LVA/Ds due to anatomical complexities. We herein report the case of a 67-year-old man who was successfully diagnosed with ventricular tachycardia originating from an idiopathic LVA that was clearly demonstrated on a three-dimensional electroanatomical mapping system integrated with CT imaging.


Subject(s)
Heart Aneurysm/diagnosis , Tachycardia, Ventricular/diagnosis , Aged , Cardiac Imaging Techniques , Echocardiography, Transesophageal , Electrocardiography , Electrophysiologic Techniques, Cardiac , Heart Aneurysm/complications , Heart Aneurysm/surgery , Heart Ventricles/pathology , Humans , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Male , Tachycardia, Ventricular/etiology , Tomography, X-Ray Computed
17.
Heart Vessels ; 23(1): 40-6, 2008 Jan.
Article in English | MEDLINE | ID: mdl-18273545

ABSTRACT

In our previous studies, using portable type signalaveraged electrocardiography (portable SAECG) with dipyridamole stress we reported that patients with coronary artery disease were identified at the bedside with high sensitivity and specificity. In this study we prospectively investigated whether coronary artery stenosis after successful percutaneous coronary intervention (PCI) could be detected. Standard 12-lead QRS wave SAECG was performed before and after dipyridamole stress at the bedside in 61 patients 8.0 +/- 9.4 months after successful PCI for myocardial infarction or angina pectoris (46 males and 15 females, mean age 66 +/- 12 years). The filtered QRS duration (fQRSd) before and after dipyridamole stress was determined by the multiphasic oscillation method at each lead of the standard 12 leads, and the maximal value of changes in fQRSd (MAX DeltafQRSd) among the 12 leads was determined. The positive test was defined as MAX DeltafQRSd > or =5 ms, and negative as MAX DeltafQRSd <5 ms based on our previous studies. Then selective coronary arteriography was performed. In the positive group (n = 24), 21 patients had stenosis (> or =50%) of the coronary artery and 3 did not. In the negative group (n = 37), 8 patients had stenosis and 29 did not. The sensitivity, specificity, positive predictive accuracy, and negative predictive accuracy for the detection of coronary artery stenosis by SAECG were 72%, 91%, 88%, and 78%, respectively. Dipyridamole stress portable SAECG is useful to detect patients with coronary artery stenosis after successful PCI.


Subject(s)
Angioplasty, Balloon, Coronary/methods , Coronary Restenosis/diagnosis , Dipyridamole , Electrocardiography/methods , Exercise Test/methods , Vasodilator Agents , Adult , Aged , Aged, 80 and over , Coronary Angiography , Coronary Restenosis/physiopathology , Coronary Restenosis/therapy , Female , Follow-Up Studies , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis , Prospective Studies , Sensitivity and Specificity , Severity of Illness Index , Time Factors
18.
Europace ; 10(3): 379-83, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18227354

ABSTRACT

AIMS: The aim of this study was to assess chronic invasive haemodynamic effects of cardiac resynchronization therapy (CRT) in patients with severe heart failure. METHODS AND RESULTS: Seventeen patients with New York Heart Association (NYHA) class III or IV and QRS duration >120 ms on optimal treatments underwent CRT. Haemodynamic data were obtained by cardiac catheterization before and 1 month after CRT. Clinical parameters and exercise tolerance were also evaluated. Chronic CRT improved haemodynamics significantly; mean pulmonary capillary wedge pressure decreased from 15.9 +/- 6.1 to 10.2 +/- 5.3 mmHg (P < 0.05), systolic pulmonary artery pressure decreased from 36.5 +/- 13.2 to 26.7 +/- 11.9 mmHg (P < 0.05), left ventricular end-diastolic pressure decreased from 15.6 +/- 7.2 to 10.5 +/- 7.3 mmHg (P < 0.05), end-diastolic volume decreased from 358.8 +/- 84.6 to 322.9 +/- 99.0 mL (P < 0.05), end-systolic volume decreased from 264.1 +/- 67.6 to 219.2 +/- 74.3 mL (P < 0.05), left ventricular ejection fraction increased from 25.4 +/- 6.2 to 33.1 +/- 4.9% (P < 0.05), and cardiac index increased from 1.9 +/- 0.4 to 2.2 +/- 0.5 L/min/m(2) (P < 0.05). Chronic CRT significantly improved functional capacity such as NYHA classification, 6 min walk distance, and peak oxygen uptake. CONCLUSION: Chronic CRT improved not only symptoms and exercise tolerance but also invasive haemodynamics associated with reversed cardiac remodelling.


Subject(s)
Blood Pressure/physiology , Cardiac Catheterization/methods , Cardiac Pacing, Artificial/methods , Heart Failure/physiopathology , Heart Failure/therapy , Stroke Volume/physiology , Ventricular Remodeling/physiology , Aged , Aged, 80 and over , Electrocardiography , Exercise Tolerance/physiology , Female , Humans , Male , Middle Aged , Pacemaker, Artificial , Treatment Outcome
19.
J Cardiovasc Electrophysiol ; 13(10): 1003-8, 2002 Oct.
Article in English | MEDLINE | ID: mdl-12435186

ABSTRACT

INTRODUCTION: Paroxysmal atrial fibrillation (PAF) frequently occurs in patients with Wolff-Parkinson-White (WPW) syndrome. Catheter ablation of the accessory pathway eliminates PAF in some patients, but PAF frequently recurs in other patients. The present study was designed to determine prospectively whether P wave signal-averaged electrocardiography (P-SAECG) predicts the recurrence of PAF after successful ablation in patients with WPW syndrome. METHODS AND RESULTS: Forty-six patients with WPW syndrome who had episodes of PAF were prospectively followed. SAECG recording was performed on day 7 after successful ablation of the accessory pathway at study entry. Abnormal P-SAECG for the prediction of recurrence of PAF was defined as a filtered P wave duration > 130 msec. Eleven patients had an abnormal P-SAECG (group 1), whereas 35 patients (group 2) did not. The two groups did not differ in terms of gender, age, left atrial dimension, and atrial vulnerability as determined by electrophysiologic study. During follow-up (40 +/- 19 months), the recurrence of PAF was noted in 10 (91%) of 11 patients in group 1, whereas it was observed in only 2 (6%) of 35 patients in group 2. Kaplan-Meier analysis revealed that the recurrence of PAF was significantly more frequent in group 1 than in group 2 (log rank test, P < 0.0001). By multivariate analysis, filtered P wave duration >130 msec was an independent predictor of recurrence of PAF after ablation (Chi-square = 21.5, P < 0.0001). CONCLUSION: The results of this study indicate that P-SAECG may be useful for identifying patients at risk for recurrence of PAF after successful ablation of WPW syndrome.


Subject(s)
Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation , Electrocardiography , Wolff-Parkinson-White Syndrome/diagnosis , Wolff-Parkinson-White Syndrome/surgery , Adolescent , Adult , Aged , Atrial Fibrillation/epidemiology , Electrophysiologic Techniques, Cardiac , Female , Follow-Up Studies , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Recurrence , Risk Factors , Sensitivity and Specificity , Treatment Outcome , Wolff-Parkinson-White Syndrome/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...