ABSTRACT

Microbridges are miniature suspended structures fabricated in silicon. Passing a current through the microbridge can heat it up to the point of incandescence. A glowing microbridge can be used as a wideband light source. This study presents a method for optical measurement of the temperature of a microbridge. Spectroscopic measurements of microbridges are optically challenging, because the multilayer structures cause interference effects. To determine the temperature from the emitted spectrum, the emissivity was modeled with thin-film Fresnel equations. Temperatures of 500-1100 degrees C were obtained from the measured spectra at different levels of applied power. The range is limited by the sensitivity of the detectors at lower power levels and by the stability of the bridge at higher levels. Results of the optical measurements were compared with contact temperature measurements made with a microthermocouple in the same temperature range. The results of the two methods agree within 100 K.

2.
Appl Opt ; 49(5): 880-6, 2010 Feb 10.
Article in English | MEDLINE | ID: mdl-20154756

ABSTRACT

We have developed a physical model for the spectral irradiance of 1 kW tungsten halogen incandescent lamps for the wavelength range 340-850 nm. The model consists of the Planck's radiation law, published values for the emissivity of tungsten, and a residual spectral correction function taking into account unknown factors of the lamp. The correction function was determined by measuring the spectra of a 1000 W, quartz-halogen, tungsten coiled filament (FEL) lamp at different temperatures. The new model was tested with lamps of types FEL and 1000 W, 120 V quartz halogen (DXW). Comparisons with measurements of two national standards laboratories indicate that the model can account for the spectral irradiance values of lamps with an agreement better than 1% throughout the spectral region studied. We further demonstrate that the spectral irradiance of a lamp can be predicted with an expanded uncertainty of 2.6% if the color temperature and illuminance values for the lamp are known with expanded uncertainties of 20 K and 2%, respectively. In addition, it is suggested that the spectral irradiance may be derived from resistance measurements of the filament with lamp on and off.

SELECTION OF CITATIONS
SEARCH DETAIL
...