1.
Eur J Orthop Surg Traumatol ; 30(8): 1505-1514, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32638123

ABSTRACT

PURPOSE: Combined anteversion (CA) technique (stem-first procedure) has become generally accepted as an ideal means to achieve optimal CA value in THA. However, we hypothesized that CA technique for patients with various native femoral anteversions could pose a risk of anterior or posterior cup protrusion. In the present study, we examined whether it is possible to use the taper wedge stem to change the stem version to achieve optimal CA while avoiding cup protrusions with the cup-first procedure through minimally invasive (MIS) antero-lateral approach. METHODS: Eighty-one patients underwent cup-first THA with a taper wedge stem. The acetabular cup was placed following the preoperative planning of the cup alignment to avoid anterior cup protrusions using CT-based navigation. Following the CA theory, anteversion of the taper wedge stem was changed to the target anteversion from the patient's native femoral anteversion. The native femoral anteversion, the change in version angle of the stem, postoperative CA and the length of anterior cup protrusions were evaluated in postoperative CT measurements. RESULTS: The native femoral anteversion averaged 25.7° ± 8.9° (range 8°-45°). Cases with increased and decreased stem anteversion were observed in 42 hips (51.8%) and 33 hips (40.7%), respectively. The amount of increased and decreased version angles averaged 7.7° ± 4.8° (range 2°-21°) and 7.8° ± 5.1° (range 2°-20°), respectively. Postoperative CA values averaged 36.7° ± 3.4° (range 29.4°-44.2°) and anterior cup protrusion length averaged 2.0 mm ± 2.6 mm (0 ~ 8.8 mm) in axial view and 0.4 mm ± 1.0 mm (0 ~ 3.6 mm) in sagittal view. Anterior cup protrusion of more than 10 mm was not observed in any hips. CONCLUSION: This procedure can be considered as an option to achieve optimal CA anteversion while avoiding anterior cup protrusion in THA.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Acetabulum/surgery , Arthroplasty, Replacement, Hip/adverse effects , Femur/diagnostic imaging , Femur/surgery , Humans , Prosthesis Design
2.
Eur J Orthop Surg Traumatol ; 30(3): 465-472, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31705402

ABSTRACT

PURPOSE: Combined anteversion (CA) technique (stem-first procedure) is generally accepted as the optimal technique to attain an appropriate CA value in total hip arthroplasty (THA). However, cup anteversion is strongly influenced by the native femoral anteversion. Accordingly, anterior protrusion of the cup in the acetabulum might occur. The purpose of the present study is to investigate the achievement of the optimal CA while avoiding anterior cup protrusion and examine the significance of our new CA technique with cup-first procedure in hybrid THA. METHODS: Seventy-nine hybrid THAs with the cup-first procedure used a CT-based navigation system for cup positioning. In the preoperative planning, cup anteversion was aimed at approximately 20°. However, in actuality, sufficient cup coverage in the original acetabulum based on individual anatomy is given priority over cup placement based on CT-based planning to ensure adequate cup coverage. The target stem anteversion was determined following Widmer's mathematical formula (37.3 = femoral stem anteversion × 0.7 + cup anteversion). Cemented stem was inserted according to the target stem anteversion angle. RESULTS: Regarding the assessment of overall alignment, the calculated Widmer's CA values during surgery and postoperative CT evaluation were 34.1° ± 6.0° (range 20.7°-51.2°) and 35.1° ± 6.7° (range 21.6°-50.7°). There were 72 hips (91.1%) within 25°-50° of CA. Cup protrusion length averaged 2.0 mm ± 2.6 mm (0-8.8 mm) in the axial view and 0.4 mm ± 1.0 mm (0-3.6 mm) in the sagittal view. Cup protrusion length of more than 5 mm was indicated in 10 hips, and no hips observed more than 10 mm. CONCLUSION: Our new CA technique (cup-first procedure) with hybrid THA was able to achieve optimal CA value while avoiding anterior cup protrusion.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Radiography, Interventional , Acetabulum/diagnostic imaging , Acetabulum/surgery , Adult , Aged , Aged, 80 and over , Female , Hip Prosthesis , Humans , Male , Middle Aged , Radiography, Interventional/methods , Tomography, X-Ray Computed
3.
Medicine (Baltimore) ; 98(27): e16090, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31277106

ABSTRACT

Kerboull-type acetabular support rings (KT) and allogenic bone graft were used for severe periacetabular bone loss with primary and revision total hip arthroplasty (THA). The purpose of this case-control study is to evaluate the risk factors related to poor outcomes of surgery.Sixty patients underwent primary THA and revision THA using allogenic bone graft with KT for large acetabular deficiency. These patients were retrospectively evaluated postoperatively and followed-up by radiograph. The minimum follow-up period was 4 years and averaged 7 years. A radiological failure was defined by the following criteria:Expected risk factors were defined as female, age >75 years, body mass index (BMI) >25%, medical history of hypertension, renal failure, liver steatosis, diabetes, hyperlipidemia, cardiac infarction, smoking, American Academy of Orthopedic Surgery (AAOS) classification III or IV, bleeding>500 mL, time of surgery >3hours, high hip center-type KT, inclination of KT >45 degrees, screw angle >25 degrees, morselized bone graft, Kawanabe's classification stage 3 or 4 and revision surgery. Nineteen hips (31.6%) revealed radiological failure according to our criteria, and revision THA was performed in 2 hips (3.3%). In the statistical analysis, morselized bone graft and high hip center-type KT were identified as factors of poor outcomes of surgery.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis/adverse effects , Prosthesis Failure/etiology , Reoperation/instrumentation , Acetabulum/diagnostic imaging , Adult , Age Factors , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/adverse effects , Bone Transplantation/adverse effects , Case-Control Studies , Female , Hip Joint/diagnostic imaging , Hip Joint/surgery , Humans , Male , Middle Aged , Reoperation/adverse effects , Retrospective Studies , Risk Factors , Sex Factors
4.
Eur J Orthop Surg Traumatol ; 29(4): 807-812, 2019 May.
Article in English | MEDLINE | ID: mdl-30656429

ABSTRACT

PURPOSE: In the combined anteversion (CA) technique for total hip arthroplasty (THA) with a cementless stem, cup anteversion is strongly influenced by the native femoral anteversion. It is hypothesized that in cases with large native femoral anteversion, cup anteversion can be decreased, and anterior cup protrusion from the anterior edge of the acetabulum could occur due to the achievement of optimal CA. In this study, the accuracy of CA in THA with the CA technique using imageless navigation and the relationship between the protrusion of the anterior edge of cup and optimum CA was retrospectively evaluated. METHODS: Ninety-seven patients (104 hips) who underwent primary THA by the CA technique using image-free navigation were enrolled in the study. The femoral stem was placed following the individual femoral anteversion so that the target cup anteversion could be determined following a mathematical formula (37 = femoral stem anteversion × 0.7 + cup anteversion). Results The resulting CA values effectively achieved accurate CA with 39.49 ± 5.03° postoperatively. On the other hand, anterior cup protrusion was measured by computed tomography image. A cup protrusion length of more than 3 mm was indicated for 60 cases (57.7%). All included patients were divided into two groups: Group 1 as protrusion positive and Group 2 as protrusion negative. In Group 1, preoperative femoral anteversion and postoperative stem anteversion were significantly higher, while postoperative cup anteversion was significantly lower. However, the postoperative CA value indicated no significant difference between the groups. CONCLUSIONS: The CA (stem-first) technique with image-free navigated THA could effectively achieve accurate CA. On the other hand, a large number of cases revealed anterior cup protrusion due to the low cup anteversion.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Femur Head/diagnostic imaging , Hip Prosthesis , Surgery, Computer-Assisted/methods , Acetabulum/diagnostic imaging , Acetabulum/surgery , Adult , Aged , Aged, 80 and over , Female , Femur Head/surgery , Humans , Male , Middle Aged , Osteoarthritis, Hip/diagnostic imaging , Osteoarthritis, Hip/surgery , Osteonecrosis/diagnostic imaging , Osteonecrosis/surgery , Postoperative Complications , Prosthesis Fitting , Retrospective Studies , Risk Factors , Tomography, Spiral Computed , Young Adult
5.
Medicine (Baltimore) ; 97(48): e13519, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30508981

ABSTRACT

RATIONALE: Curved periacetabular osteotomy (CPO) is a procedure with excellent surgical outcome that has been proposed for patients with development dysplasia of the hip (DDH). However, the surgical outcomes depend on the surgeon's experience and proficiency. PATIENT CONCERNS: A 38-year-old female indicated she was experiencing left hip pain while walking. DIAGNOSES: The patient was diagnosed with early-stage hip osteoarthritis due to DDH. INTERVENTIONS: The patient underwent CPO while a 3-dimensional flat-panel C-arm (Artis zeego; Sciemens Healthcare, Forchheim, Germany) was used to confirm the real-time 3-dimensional computed tomography (CT) images during surgery. It was possible to confirm the accurate osteotomy curve using CT images twice during surgery: at the time of the ischial osteotomy and the quadrilateral surface osteotomy. OUTCOMES: An ideal C-shaped osteotomy line was created as shown on the postoperative CT images. In addition, neither posterior column fracture nor intra-articular osteotomy was confirmed. LESSONS: The CPO using Artis zeego resulted is a satisfactory outcome, and this is the 1st report in the world to discuss the benefits of Artis zeego in pelvic osteotomy.


Subject(s)
Imaging, Three-Dimensional/methods , Osteoarthritis, Hip/surgery , Osteotomy/methods , Robotic Surgical Procedures/methods , Tomography, X-Ray Computed/methods , Acetabulum/surgery , Adult , Female , Hip Dislocation, Congenital/complications , Humans , Intraoperative Period , Osteoarthritis, Hip/congenital
SELECTION OF CITATIONS