1.
ASAIO J ; 47(6): 677-82, 2001.
Article in English | MEDLINE | ID: mdl-11730210

ABSTRACT

The Omnicarbon prosthetic valve was implanted in 168 patients (mean age, 53 years); 84 had aortic valve replacement (AVR), 57 had mitral valve replacement (MVR), and 27 had both aortic and mitral valve replacement (DVR). The mean follow-up period was 6.8 years, with a maximum of 13.7 years. Three patients (1.8%) were lost to follow-up. There were 4 (2.4%) early deaths and 26 late deaths. Survival at 10 years was 76% in the AVR and MVR groups, and 85% in the DVR group. Freedom from thromboembolism at 10 years was 94% in the AVR group, 80% in the MVR group, and 92% in the DVR group. Freedom from hemorrhagic complications at 10 years was 86% in the AVR group and 92% in the MVR group. At 10 years, 97% in the AVR group and 96% in the MVR group were free from endocarditis. One patient in the DVR group suffered a paravalvular leak. At 10 years, 97% in the AVR group and 95% in the MVR group had not needed reoperation. Elevation of the postoperative serum lactate dehydrogenase levels were acceptable in the three groups. In conclusion, the Omnicarbon prosthetic valve has shown excellent long-term clinical results.


Subject(s)
Aortic Valve Insufficiency/surgery , Heart Valve Prosthesis/statistics & numerical data , Mitral Valve Insufficiency/surgery , Postoperative Complications/mortality , Disease-Free Survival , Endocarditis/mortality , Follow-Up Studies , Hospital Mortality , Humans , Middle Aged , Survival Rate , Thromboembolism/mortality
2.
ASAIO J ; 47(5): 563-4, 2001.
Article in English | MEDLINE | ID: mdl-11575838

ABSTRACT

Primary tissue failure of bioprosthetic heart valves refers primarily to calcification of the leaflets of the bioprosthesis. A 75 year old patient underwent reoperation 15 years after mitral valve replacement with a Carpentier-Edwards porcine bioprosthesis. The extracted bioprosthetic valve was found to have one prolapsed leaflet and a small amount of calcification on all three leaflets without tear or perforation. The two commissures suspending the prolapsed leaflet were detached, causing mitral valve regurgitation.


Subject(s)
Bioprosthesis/adverse effects , Heart Valve Prosthesis/adverse effects , Aged , Animals , Equipment Failure Analysis , Humans , Male , Mitral Valve , Prosthesis Failure , Reoperation , Swine , Time Factors