Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Eng Sci Med ; 47(2): 465-475, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38265521

ABSTRACT

Intensity-modulated radiation therapy (IMRT) has become a popular choice for breast cancer treatment. We aimed to evaluate and compare the robustness of each optimization method used for breast IMRT using TomoTherapy. A retrospective analysis was performed on 10 patients with left breast cancer. For each optimization method (clipping, virtual bolus, and skin flash), a corresponding 50 Gy/25 fr plan was created in the helical and direct TomoTherapy modes. The dose-volume histogram parameters were compared after shifting the patients anteriorly and posteriorly. In the helical mode, when the patient was not shifted, the median D1cc (minimum dose delivered to 1 cc of the organ volume) of the breast skin for the clipping and virtual bolus plans was 52.2 (interquartile range: 51.9-52.6) and 50.4 (50.1-50.8) Gy, respectively. After an anterior shift, D1cc of the breast skin for the clipping and virtual bolus plans was 56.0 (55.6-56.8) and 50.9 (50.5-51.3) Gy, respectively. When the direct mode was used without shifting the patient, D1cc of the breast skin for the clipping, virtual bolus, and skin flash plans was 52.6 (51.9-53.1), 53.4 (52.6-53.9), and 52.3 (51.7-53.0) Gy, respectively. After shifting anteriorly, D1cc of the breast skin for the clipping, virtual bolus, and skin flash plans was 55.6 (54.1-56.4), 52.4 (52.0-53.0), and 53.6 (52.6-54.6) Gy, respectively. The clipping method is not sufficient for breast IMRT. The virtual bolus and skin flash methods were more robust optimization methods according to our analyses.


Subject(s)
Breast Neoplasms , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Female , Breast Neoplasms/radiotherapy , Breast Neoplasms/diagnostic imaging , Radiotherapy Dosage , Middle Aged , Dose-Response Relationship, Radiation , Retrospective Studies , Breast/diagnostic imaging
2.
J Appl Clin Med Phys ; 24(5): e13910, 2023 May.
Article in English | MEDLINE | ID: mdl-36650923

ABSTRACT

PURPOSE: The CyberKnife system is a specialized device for non-coplanar irradiation; however, it possesses the geometric restriction that the beam cannot be irradiated from under the treatment couch. Prone positioning is expected to reduce the dose to normal lung tissue in spinal stereotactic body radiotherapy (SBRT) owing to the efficiency of beam arrangement; however, respiratory motion occurs. Therefore, the Xsight spine prone tracking (XSPT) system is used to reduce the effects of respiratory motion. The purpose of this study was to evaluate the motion-tracking error of the spine in the prone position. MATERIALS AND METHODS: Data from all 25 patients who underwent spinal SBRT at our institution between April 2020 and February 2022 using CyberKnife (VSI, version 11.1.0) with the XSPT tracking system were retrospectively analyzed using log files. The tumor motion, correlation, and prediction errors for each patient were examined. Furthermore, to assess the potential relationships between the parameters, the relationships between the tumor-motion amplitudes and correlation or prediction errors were investigated using linear regression. RESULTS: The tumor-motion amplitudes in each direction were as follows: superior-inferior (SI), 0.51 ± 0.39 mm; left-right (LR), 0.37 ± 0.29 mm; and anterior-posterior (AP), 3.43 ± 1.63 mm. The overall mean correlation and prediction errors were 0.66 ± 0.48 mm and 0.06 ± 0.07 mm, respectively. The prediction errors were strongly correlated with the tumor-motion amplitudes, whereas the correlation errors were not. CONCLUSIONS: This study demonstrated that the correlation error of spinal SBRT in the prone position is sufficiently small to be independent of the tumor-motion amplitude. Furthermore, the prediction error is small, contributing only slightly to the tracking error. These findings will improve the understanding of how to compensate for respiratory-motion uncertainty in the prone position.


Subject(s)
Neoplasms , Radiosurgery , Humans , Retrospective Studies , Prone Position , Radiotherapy Planning, Computer-Assisted , Motion
3.
J Appl Clin Med Phys ; 23(6): e13596, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35377962

ABSTRACT

PURPOSE: Real-time tracking systems of moving respiratory targets such as CyberKnife, Radixact, or Vero4DRT are an advanced robotic radiotherapy device used to deliver stereotactic body radiotherapy (SBRT). The internal target volume (ITV) of lung tumors is assessed through a fiducial marker fusion using four-dimensional computed tomography (CT). It is important to minimize the ITV to protect normal lung tissue from exposure to radiation and the associated side effects post SBRT. However, the ITV may alter if there is a change in the position of the fiducial marker with respect to the tumor. This study investigated the relationship between fiducial marker position and the ITV in order to prevent radiation exposure of normal lung tissue, and correct target coverage. MATERIALS AND METHODS: This study retrospectively reviewed 230 lung cancer patients who received a fiducial marker for SBRT between April 2015 and September 2021. The distance of the fiducial marker to the gross tumor volume (GTV) in the expiratory (dex ) and inspiratory (din ) CT, and the ratio of the ITV/V(GTVex ), were investigated. RESULTS: Upon comparing each lobe, although there was no significant difference in the ddiff and the ITV/V(GTVex ) between all lobes for dex  < 10 mm, there was significant difference in the ddiff and the ITV/V(GTVex ) between the lower and upper lobes for dex ≥ 10 mm (p < 0.05). Moreover, there was significant difference in the ddiff and the ITV/V(GTVex ) between dex ≥10 mm and dex  < 10 mm in all lung regions (p < 0.05). CONCLUSION: The ITV that had no margin from GTVs increased when dex was ≥10 mm for all lung regions (p < 0.05). Furthermore, the increase in ITV tended to be greater in the lower lung lobe. These findings can help decrease the possibility of adverse events post SBRT, and correct target coverage.


Subject(s)
Lung Neoplasms , Radiosurgery , Fiducial Markers , Four-Dimensional Computed Tomography/methods , Humans , Lung/diagnostic imaging , Lung/pathology , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Lung Neoplasms/surgery , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Retrospective Studies
4.
Phys Imaging Radiat Oncol ; 20: 94-97, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34869923

ABSTRACT

Metal-based nanoparticles (NPs) have been extensively studied for dose enhancement applications in radiation therapy. This study investigated the utility of such NPs for image-guided radiation therapy (IGRT). Phantom images of gold NPs (AuNPs) and titanium peroxide NPs (TiOxNPs) with different concentrations were acquired using IGRT modalities, including cone-beam computed tomography (CBCT). AuNPs induced strong contrast enhancement in kV energy CBCT images, whereas TiOxNPs at high concentrations showed weak but detectable changes. The results indicated that these NPs can be used to enhance IGRT images as well as dose enhancement for treatment purposes.

5.
J Appl Clin Med Phys ; 22(9): 280-288, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34359100

ABSTRACT

In prostate stereotactic body radiation therapy (SBRT), hydrogel spacers are increasingly used. This study aimed to perform a dosimetry comparison of treatment plans using CyberKnife (CK), commonly used for prostate SBRT, Helical TomoTherapy (HT), and TrueBeam (TB) in patients with hydrogel spacer implantations. The data of 20 patients who received hydrogel spacer implantation for prostate SBRT were retrospectively analyzed. The prescription dose was 36.25 Gy in five fractions to 95% of the planning target volume (PTV; D95). The conformity index (CI), gradient index (GI), homogeneity index (HI), and dose-volume histogram (DVH) were analyzed for the three modalities, using the same PTV margins. The monitor unit (MU) and the beam-on-time (BOT) values were subsequently compared. The CI of TB (0.93 ± 0.02) was significantly superior to those of CK (0.82 ± 0.03, p < 0.01) and HT (0.86 ± 0.03, p < 0.01). Similarly, the GI value of TB (3.59 ± 0.12) was significantly better than those of CK (4.31 ± 0.43, p < 0.01) and HT (4.52 ± 0.24, p < 0.01). The median doses to the bladder did not differ between the CK and TB (V18.1 Gy: 16.5% ± 4.5% vs. 15.8% ± 4.4%, p = 1.00), but were significantly higher for HT (V18.1 Gy: 33.2% ± 7.3%, p < 0.01 vs. CK, p < 0.01 vs. TB). The median rectal dose was significantly lower for TB (V18.1 Gy: 5.6% ± 4.5%) than for CK (V18.1 Gy: 11.2% ± 6.7%, p < 0.01) and HT (20.2% ± 8.3%, p < 0.01). TB had the shortest BOT (2.6 min; CK: 17.4 min, HT: 6.9 min). TB could create treatment plans dosimetrically comparable to those of CK when using the same margins, in patients with hydrogel spacers.


Subject(s)
Radiosurgery , Radiotherapy, Intensity-Modulated , Humans , Male , Prostate , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...