Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Bioorg Med Chem ; 22(21): 6026-38, 2014 Nov 01.
Article in English | MEDLINE | ID: mdl-25281269

ABSTRACT

A series of 9-disubstituted N-(9H-fluorene-2-carbonyl)guanidine derivatives have been discovered as potent and orally active dual 5-HT(2B) and 5-HT(7) receptor antagonists. Upon screening several compounds, N-(diaminomethylene)-4',5'-dihydro-3'H-spiro[fluorene-9,2'-furan]-2-carboxamide (17) exhibited potent affinity for both 5-HT(2B) (Ki = 5.1 nM) and 5-HT(7) (K(i) = 1.7 nM) receptors with high selectivity over 5-HT(2A), 5-HT(2C), α(1), D(2) and M(1) receptors. Optical resolution of the intermediate carboxylic acid 16 via the formation of diastereomeric salts using chiral alkaloids gave the optically pure compounds (R)-17 and (S)-17. Both enantiomers suppressed 5-HT-induced dural protein extravasation in guinea pigs in a dose-dependent manner and the amount of leaked protein was suppressed to near normal levels when orally administrated at 10 mg/kg. (R)-17 and (S)-17 were therefore selected as candidates for human clinical trials.


Subject(s)
Receptor, Serotonin, 5-HT2B/metabolism , Receptors, Serotonin/metabolism , Serotonin Antagonists/chemistry , Serotonin Antagonists/pharmacology , Animals , CHO Cells , Cricetulus , Guinea Pigs , HEK293 Cells , Humans , Molecular Docking Simulation , Serotonin 5-HT2 Receptor Antagonists/chemical synthesis , Serotonin 5-HT2 Receptor Antagonists/chemistry , Serotonin 5-HT2 Receptor Antagonists/pharmacology , Serotonin Antagonists/chemical synthesis
2.
Igaku Butsuri ; 22(3): 159-72, 2002.
Article in English | MEDLINE | ID: mdl-12766280

ABSTRACT

Measurement of the rate constant parameters of the tracer 18F-FDG, used with positron emission tomography (PET) to determine the cerebral metabolic rate of glucose (CMRGlc), can provide a clear understanding of the physiological processes in the human brain. At present, the methods that are widely used to obtain CMRGlc, such as nonlinear least squares (NLS), first require the reconstruction of a time sequence of images. The reconstruction of these images requires a large amount of computation, especially in 3D Depth-of Interaction PET (DOI-PET), and the nonlinear based methods also require a large amount of computation. In this paper, we propose a fast parametric image reconstruction method for 18F-FDG dynamic PET studies. In our method a deconvolving process is first employed on the time sequential projection data to remove the effect of the measured plasma time activity. The deconvolved terms are integrated over three different time intervals and the parameters for determining CMRGlc can be obtained analytically. Our method requires only three reconstructing processes and reduces the computational demand to estimate CMRGlc. The algorithm performance is evaluated using a digital phantom and a clinical data set and the results show that the proposed method produces images with the same or better quality as the images from the NLS method, with much less computation compared to the NLS method.


Subject(s)
Brain/diagnostic imaging , Brain/metabolism , Glucose/metabolism , Image Processing, Computer-Assisted/methods , Tomography, Emission-Computed , Algorithms , Computer Simulation , Fluorine Radioisotopes , Fluorodeoxyglucose F18 , Humans , Imaging, Three-Dimensional/methods , Radiopharmaceuticals
SELECTION OF CITATIONS
SEARCH DETAIL
...