Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Hosp Pharm ; 52(8): 570-573, 2017 Sep.
Article in English | MEDLINE | ID: mdl-29276291

ABSTRACT

Objective: The objective of this study was to evaluate the stability of epinephrine hydrochloride in 0.9% sodium chloride in polyvinyl chloride bags for up to 60 days. Methods: Dilutions of epinephrine hydrochloride to concentrations of 16 and 64 µg/mL were performed under aseptic conditions. The bags were then placed into ultraviolet light-blocking bags and stored at room temperature (23°C-25°C) or under refrigeration (3°C-5°C). Three samples of each preparation and storage environment were analyzed on days 0, 30, 45, and 60. Physical stability was performed by visual examination. The pH was assessed at baseline and upon final degradation evaluation. Sterility of the samples was not assessed. Chemical stability of epinephrine hydrochloride was evaluated using high-performance liquid chromatography. To determine the stability-indicating nature of the assay, degradation 12 months following preparation was evaluated. Samples were considered stable if there was less than 10% degradation of the initial concentration. Results: Epinephrine hydrochloride diluted to 16 and 64 µg/mL with 0.9% sodium chloride injection and stored in amber ultraviolet light-blocking bags was physically stable throughout the study. No precipitation was observed. At days 30 and 45, all bags had less than 10% degradation. At day 60, all refrigerated bags had less than 10% degradation. Overall, the mean concentration of all measurements demonstrated less than 10% degradation at 60 days at room temperature and under refrigeration. Conclusion: Epinephrine hydrochloride diluted to 16 and 64 µg/mL with 0.9% sodium chloride injection in polyvinyl chloride bags stored in amber ultraviolet light-blocking bags was stable up to 45 days at room temperature and up to 60 days under refrigeration.

2.
Int J Pharm Compd ; 20(6): 521-525, 2016.
Article in English | MEDLINE | ID: mdl-28339392

ABSTRACT

The primary aim of this study was to investigate ribavirin solution for inhalation stability under three different conditions (frozen, refrigerated, room temperature) over a 45-day period. A ribavirin 6000-mg vial was reconstituted with 90 mL of Sterile Water for Injection per the package insert to yield a concentration of approximately 67 mg/mL. The solution was then placed in either syringes or empty glass vials and stored in the freezer (-20°C), in the refrigerator (~0°C to 4°C), or at room temperature (~20°C to 25°C). Original concentrations were measured on day 0 and subsequent concentrations were measured on day 2, 14, and 45 utilizing a validated liquid chromatography with tandem mass spectrometry assay. All analyses were performed in triplicate for each storage condition. Additionally, at each time point the physical stability was evaluated and the pH of solution was measured. The solution was considered stable if =90% of the original concentration was retained over the study period. A validated liquid chromatography with tandem mass spectrometry analysis demonstrated that >95% of the original ribavirin concentration was preserved over the 45-day period for all study conditions. The ribavirin concentration remained within the United States Pharmacopeia (USP)-required range of 95% to 105% of the original labeled product amount throughout the entire study period for all study conditions. Precipitation of ribavirin was noted during the thawing cycle for frozen samples, but the drug went back into solution once the thawing process was completed. No changes in color or turbidity were observed in any of the prepared solutions. Values for pH remained stable over the study period and ranged from 4.1 to 5.3. Ribavirin for inhalation solution is physically and chemically stable for at least 45 days when frozen, refrigerated, or kept at room temperature after reconstitution to a concentration of approximately 67 mg/mL and placed in syringes or glass vials.


Subject(s)
Antiviral Agents/administration & dosage , Antiviral Agents/chemistry , Drug Packaging , Glass/chemistry , Ribavirin/administration & dosage , Ribavirin/chemistry , Syringes , Administration, Inhalation , Chromatography, Reverse-Phase , Cold Temperature , Drug Compounding , Drug Stability , Drug Storage , Hydrogen-Ion Concentration , Pharmaceutical Solutions , Solubility , Tandem Mass Spectrometry , Time Factors
3.
Hosp Pharm ; 50(1): 34-41, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25684799

ABSTRACT

PURPOSE: To measure the effects associated with sequential implementation of electronic medication storage and inventory systems and product verification devices on pharmacy technical accuracy and rates of potential medication dispensing errors in an academic medical center. METHODS: During four 28-day periods of observation, pharmacists recorded all technical errors identified at the final visual check of pharmaceuticals prior to dispensing. Technical filling errors involving deviations from order-specific selection of product, dosage form, strength, or quantity were documented when dispensing medications using (a) a conventional unit dose (UD) drug distribution system, (b) an electronic storage and inventory system utilizing automated dispensing cabinets (ADCs) within the pharmacy, (c) ADCs combined with barcode (BC) verification, and (d) ADCs and BC verification utilized with changes in product labeling and individualized personnel training in systems application. RESULTS: Using a conventional UD system, the overall incidence of technical error was 0.157% (24/15,271). Following implementation of ADCs, the comparative overall incidence of technical error was 0.135% (10/7,379; P = .841). Following implementation of BC scanning, the comparative overall incidence of technical error was 0.137% (27/19,708; P = .729). Subsequent changes in product labeling and intensified staff training in the use of BC systems was associated with a decrease in the rate of technical error to 0.050% (13/26,200; P = .002). CONCLUSIONS: Pharmacy ADCs and BC systems provide complementary effects that improve technical accuracy and reduce the incidence of potential medication dispensing errors if this technology is used with comprehensive personnel training.

4.
Hosp Pharm ; 49(5): 455-7, 2014 May.
Article in English | MEDLINE | ID: mdl-24958958

ABSTRACT

PURPOSE: Phenylephrine hydrochloride (HCl) is commonly used to maintain adequate blood pressure during shock and shocklike states. Phenylephrine is prepared in concentrated stock vials that require further dilution prior to administration. This study evaluated the physical and chemical stability of phenylephrine in extemporaneously prepared polyvinyl chloride (PVC) bags. METHODS: Phenylephrine HCl 10 mg/mL solution was diluted with 0.9% sodium chloride for injection to final concentrations of 200 µg/mL and 400 µg/mL and stored at room temperature (23°C-25°C) exposed to fluorescent light. Stability of phenylephrine HCl was evaluated by high-performance liquid chromatography on days 0, 7, 14, 21, 30, 45, and 60. RESULTS: Phenylephrine HCl 200 and 400 µg/mL solutions in PVC bags were physically stable during the entire 60-day study period. Phenylephrine HCl retained > 95% of the original concentration. CONCLUSION: Phenylephrine HCl diluted to 200 or 400 µg/mL with 0.9% sodium chloride for injection is both physically and chemically stable for a period of 60 days with ≤5% degradation when stored at room temperature and exposed to fluorescent lighting.

5.
Am J Health Syst Pharm ; 64(10): 1092-5, 2007 May 15.
Article in English | MEDLINE | ID: mdl-17494910

ABSTRACT

PURPOSE: The stability of extemporaneously prepared phenylephrine hydrochloride injection stored in polypropylene syringes was studied. METHODS: Dilution of phenylephrine hydrochloride to a nominal concentration of 100 mug/mL was performed under aseptic conditions by adding 100 mg of phenylephrine hydrochloride (total of 10 mL from two 5-mL 10-mg/mL vials) to 1000 mL of 0.9% sodium chloride injection. The resulting solution was drawn into 10-mL polypropylene syringes and sealed with syringe caps. The syringes were then frozen (-20 degrees C), refrigerated (3-5 degrees C), or kept at room temperature (23-25 degrees C). Four samples of each preparation were analyzed on days 0, 7, 15, 21, and 30. Physical stability was assessed by visual examination. The pH of each syringe was also measured at each time point. Sterility of the samples was not assessed. Chemical stability of phenylephrine hydrochloride was evaluated using high-performance liquid chromatography. To demonstrate the stability-indicating nature of the assay, forced degradation of phenylephrine was conducted. Samples were considered stable if there was less than 10% degradation of the initial concentration. RESULTS: Phenylephrine hydrochloride diluted to 100 microg/mL with 0.9% sodium chloride injection was physically stable throughout the study. No precipitation was observed. Minimal to no degradation was observed over the 30-day study period. CONCLUSION: Phenylephrine hydrochloride diluted to a concentration of 100 mug/mL in 0.9% sodium chloride injection was stable for at least 30 days when stored in polypropylene syringes at -20 degrees C, 3-5 degrees C, and 23-25 degrees C.


Subject(s)
Phenylephrine/chemistry , Polypropylenes , Sympathomimetics/chemistry , Chromatography, High Pressure Liquid , Drug Stability , Drug Storage , Syringes , Temperature
6.
Am J Health Syst Pharm ; 64(7): 762-6, 2007 Apr 01.
Article in English | MEDLINE | ID: mdl-17384363

ABSTRACT

PURPOSE: The physical and chemical stability of repackaged acetylcysteine 600 mg/3 mL solution in oral syringes stored under refrigeration or at room temperature was studied for six months; a cost analysis was also conducted. METHODS: Acetylcysteine 20% solution for inhalation was repackaged undiluted as 600 mg/3 mL in capped oral syringes and stored either under refrigeration or at room temperature exposed to fluorescent light. Four samples for each storage condition were analyzed in duplicate on day zero, weekly for the first month, and then every two weeks during months 2-6. Physical stability was assessed, and the chemical stability of acetylcysteine was evaluated by high-performance liquid chromatography. RESULTS: Acetylcysteine solution in syringes was physically stable during the entire six-month study period. When stored at room temperature, acetylcysteine retained 99% of the original concentration at three months and 95% at six months after preparation of the syringes. Loss of acetylcysteine was <2% at six months when stored under refrigeration. Packaging acetylcysteine in batches of 100 syringes instead of preparing individual syringes reduced wastage to zero syringes, saving an estimated $247 in drug costs. The estimated pharmacy time savings was 30 hours ($702). CONCLUSION: Acetylcysteine 20% solution repackaged as 600 mg/3 mL in oral syringes is both physically and chemically stable under refrigeration or at room temperature under normal fluorescent lighting for six months. The total loss of acetylcysteine was approximately 5% at room temperature under fluorescent lighting and <2% under refrigeration. Repackaging the solution in syringes in bulk rather than in single doses demonstrated a measurable cost saving.


Subject(s)
Acetylcysteine/economics , Drug Packaging , Expectorants/economics , Syringes , Acetylcysteine/administration & dosage , Administration, Oral , Chromatography, Liquid , Cost Control , Drug Stability , Drug Storage/methods , Expectorants/administration & dosage , Temperature , United States
SELECTION OF CITATIONS
SEARCH DETAIL
...