Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
Arch Phys Med Rehabil ; 104(12): 2084-2091, 2023 12.
Article in English | MEDLINE | ID: mdl-37290491

ABSTRACT

OBJECTIVE: The objective of this study was to examine measurement properties of the Joint replacement version for Hip Disability and Osteoarthritis Outcome Score (HOOS-JR) using Rasch analysis in patients with osteoarthritis of hip (HOA). DESIGN: Cross-sectional clinical measurement SETTING: Patient outcomes database at a tertiary care hospital PARTICIPANTS: Convenience sampling of patients with HOA scheduled for total hip arthroplasty (N=327) OUTCOME MEASURES AND ANALYSIS: The data for pre-surgery assessments for patients with HOA were extracted from an existing database. Variables extracted included HOOS-JR scores, demographic information (age, sex), health-related data, and anthropometric variables. The assumptions of Rasch model such as the test of fit, fit residuals, ordering of item thresholds, factor structure, DIF, internal consistency and Pearson separation index were examined for the HOOS-JR scores. RESULTS: The HOOS-JR showed adequate overall fit to the Rasch model, logically ordered response thresholds, no floor or ceiling effects, and high internal consistency (Cronbach's alpha of 0.91). The HOOS-JR did not satisfy the assumption of unidimensionality, albeit the violation of this assumption was marginal (6.12% over 5%). Person-item threshold distribution (difference between person and item means were equal to 0.92 which was less than 1 logit unit) confirmed that the HOOS-JR scores were well targeted. CONCLUSIONS: Given that the violation of unidimensionality for HOOS-JR was marginal, we recommend further studies to validate this finding. Results broadly support the use of HOOS-JR for assessing hip health in patients with HOA.


Subject(s)
Arthroplasty, Replacement, Hip , Osteoarthritis, Hip , Humans , Osteoarthritis, Hip/surgery , Cross-Sectional Studies , Reproducibility of Results , Pain Measurement/methods , Patient Reported Outcome Measures
2.
Arch Bone Jt Surg ; 10(6): 514-524, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35928909

ABSTRACT

Background: Implant removal due to infection is one of the major causes failure following open reduction and internal fixation (ORIF). The aim of this study was to determine trends and predictors of infection-related implant removal following ORIF of extremities using a nationally representative database. Methods: Nationwide Inpatient Sample data from 2006 to 2017 was used to identify cases of ORIF following upper and lower extremity fractures, as well as cases that underwent infection-related implant removal following ORIF. Multivariate analysis was performed to identify independent predictors of infection-related implant removal, controlling for patient demographics and comorbidities, hospital characteristics, site of fracture, and year. Results: For all ORIF procedures, the highest rate of implant removal due to infection was the phalanges/hand (5.61%), phalanges/foot (5.08%), and the radius/ulna (4.85%). Implant removal rates due to infection decreased in all fractures except radial/ulnar fractures. Tarsal/metatarsal fractures (odds ratio (OR)=1.45, 95% confidence interval (CI): 1.02-2.05), and tibial fractures (OR=1.82, 95% CI: 1.45-2.28) were identified as independent predictors of infection-related implant removal. Male gender (OR=1.67, 95% CI: 1.49-1.87), Obesity (OR=1.85, 95% CI: 1.34-2.54), diabetes mellitus with chronic complications (OR=1.69, 95% CI: 1.13-2.54, P<0.05), deficiency anemia (OR=1.59, 95% CI: 1.14-2.22) were patient factors that were associated with increased infection-related removals. Removal of implant due to infection had a higher total charge associated with the episode of care (mean: $166,041) than non-infection related implant removal (mean: $133,110). Conclusion: Implant removal rates due to infection decreased in all fractures except radial/ulnar fractures. Diabetes, liver disease, and rheumatoid arthritis were important predictors of infection-related implant removal. The study identified some risk factors for implant related infection following ORIF, such as diabetes, obesity, and anemia, that should be studied further to implement strategies to reduce rate of infection following ORIF.

3.
Arthroplast Today ; 16: 197-202, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35844266

ABSTRACT

Background: Aseptic loosening of the cemented tibial component is a source of failure in total knee arthroplasty. This study examined common techniques for cement application by quantifying depth and volume of penetration into tibia models. Material and methods: Thirty-six composite tibia models were cemented with a tibial component using 3 application techniques (gun, osteotome, and layered) with either early or late cement working time. Computed tomography and 3D-modeling were used to quantify volume and depth of penetration. Statistical analysis was conducted with analysis of variance with Bonferroni correction and Student's t-test. Results: No difference was found in overall volume of penetration between early and late cement application (P = .16). Beneath the baseplate, the layered technique had significantly less penetration and averaged less than 3 mm with early and late cement. The gun technique had the greatest depth of penetration with early cement and averaged greater than 3 mm in all zones regardless of cement working time. The osteotome technique achieved significantly greater depth of penetration around the keel with early and late cement, P < .01. Conclusions: Using a cement gun ensures adequate penetration beneath the baseplate regardless of cement working time while the osteotome technique is effective to increase penetration around the implant keel. According to our study, applying cement early in its working time may not increase volume of penetration. This study raises concern regarding adequate cement penetration using the layered technique for cementing the tibial component in total knee arthroplasty, and future research is warranted.

4.
J Knee Surg ; 35(2): 150-158, 2022 Jan.
Article in English | MEDLINE | ID: mdl-32643782

ABSTRACT

The aim of this study was to verify the single-factor structure of the joint replacement version of the Knee Injury and Osteoarthritis Outcome Score (KOOS-JR) and examine its measurement properties in the context of Rasch analysis in patients with end-stage osteoarthritis of the knee (KOA) awaiting total knee replacement (TKR). The study design was retrieval of prospectively collected clinical data. The data were extracted from the presurgery visit for individuals with KOA who were scheduled for primary TKR at a tertiary care hospital. Those who were scheduled for revision of TKR had any other lower extremity injury or surgery during 6 months prior to the presurgery visit, or those who had reported pre-existing neurological impairments affecting the lower extremity functions were excluded during data extraction. The assumptions of Rasch analysis that were examined included the test of fit, fit of residuals, ordering of item thresholds, Pearson separation index, differential item functioning (DIF), dependency, and unidimensionality. The main outcome measure was KOOS-JR. Data were extracted for 283 patients, including 112 men and 160 women, from clinical charts. The KOOS-JR demonstrated good overall fit to the Rasch model. However, it failed to meet the assumption of unidimensionality. None of the items demonstrated DIF or concerns with response thresholds. Person-item threshold distribution indicated that the score for KOOS-JR overestimated person traits with floor and ceiling effects. Reliability statistics were equal to 0.9, suggesting that seven items within the KOOS-JR were internally consistent and reliable. The hypothetical unidimensional KOOS-JR could not be reproduced in our sample in that KOOS-JR had a latent construct. Future research should perform exploratory factor analysis to examine this latent construct.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Injuries , Osteoarthritis, Knee , Female , Humans , Knee Joint , Male , Osteoarthritis, Knee/surgery , Reproducibility of Results , Surveys and Questionnaires
5.
Arch Bone Jt Surg ; 9(1): 33-43, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33778113

ABSTRACT

Consistent diagnosis of periprosthetic infection in total joint arthroplasty continues to elude the orthopedic surgeon because no gold standard test exists. Therefore clinicians must rely on a combination of tests to help aid the diagnosis. The expanding role of biomarkers has shown promising results to more accurately diagnose an infection when combined with clinical suspicion and bacterial culture testing. This paper reviews the diagnostic capabilities of the most current serum and synovial biomarkers as well as next generation sequencing in the setting of periprosthetic joint infection. Future research and high-powered studies will be necessary to determine sensitivity and specificity of each biomarker.

6.
Arthrosc Tech ; 10(2): e475-e479, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33680781

ABSTRACT

Knee arthroscopy has evolved greatly from its inception in the 20th century. Arthroscopic synovectomy is performed in the case of infection or significant synovitis. We continue to develop more minimally invasive procedures, and the NanoScope (Arthrex, Naples, FL) has provided a new generation of possibilities. The system does not require the use of a standard incision or portal, and using the GraftNet (Arthrex), we can harvest tissue with a standard shaver for further evaluation. This technique provides an option to perform a synovial and bone biopsy in a painful total knee arthroplasty without the use of standard arthroscopy portals through an incisionless approach. This technique provides distinct advantages over a more open approach in the setting of a prosthetic joint. Specifically, this technique is useful for a difficult-to-diagnose painful total knee arthroplasty.

7.
J Bodyw Mov Ther ; 25: 67-74, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33714514

ABSTRACT

INTRODUCTION: Smartphone app-based goniometer (SG) are emerging as an alternative to Universal Goniometers (UG) in assessing joint range of motion (ROM). This study examined whether the experience level of examiner affected the reliability of assessing knee flexion (KF) and knee extension (KE) ROM using UG and SG. METHODS: Participants with osteoarthritis of the knee or following total knee replacement were recruited. KF and KE ROM using UG and SG were assessed twice by an experienced physical therapist (PT) and a student PT (SPT). Intraclass correlation coefficients (ICC) examined the interrater (experienced PT vs SPT) and intrarater reliabilities (for experienced PT and SPT) in assessing KF and KE ROM for UG and SG. Concurrent relationships were examined between the knee ROM with pain and physical function using Pearson Correlation Coefficient (r). RESULTS: The interrater reliability in assessing KF and KE ROM was excellent (ICC>0.90) between novice and experienced examiners. The standard error of measurement (SEM) for novice examiner in assessing KF was 1° and 2° while using UG and SG respectively; whereas the SEM for experienced examiner in assessing KF was 1° irrespective of which device was used. The concurrent relationships between KF and KE ROM with measures of pain and function were divergent (moderate to low correlations; r <0.7; p > 0.05). CONCLUSION: Both UG and SG have smaller measurement error in assessing KF and KE ROM irrespective of experience level of examiner and therefore no one tool is superior than the other for assessing knee ROM in clinical practice.


Subject(s)
Physical Therapists , Smartphone , Arthrometry, Articular , Humans , Range of Motion, Articular , Reproducibility of Results
8.
Arthrosc Tech ; 9(9): e1259-e1262, 2020 Sep.
Article in English | MEDLINE | ID: mdl-33024664

ABSTRACT

Knee arthroscopy has evolved greatly from its inception in the 20th century. Arthroscopic synovectomy is performed in the case of infection or significant synovitis. We continue to develop more minimally invasive procedures, and the NanoScope (Arthrex, Naples, FL) has provided a new generation of possibilities. The system does not require the use of a standard incision or portal, and using the GraftNet (Arthrex), we can harvest tissue with a standard shaver for further evaluation. This technique provides an option to perform a synovectomy and biopsy without the use of standard arthroscopy portals through an incisionless approach.

9.
J Arthroplasty ; 35(12): 3743-3746, 2020 12.
Article in English | MEDLINE | ID: mdl-32788061

ABSTRACT

BACKGROUND: Persistent wound drainage (PWD) is one of the major risk factors for periprosthetic joint infections (PJI), arguably the most dreaded complications after a total hip and knee arthroplasty (THA and TKA). The aim of this study is to identify the rates of PWD among THA and TKA patients who received aspirin (ASA) or Coumadin for postoperative venous thromboembolism (VTE) prophylaxis. METHODS: Retrospective review of 5516 primary THA and TKA was performed. Patients with PWD were identified. Chi-square test was used to compare the incidences of PWD, 30-day VTE, and PJI at 6 months between the ASA and Coumadin groups. Multivariate regression model was used to identify independent risk factors for PWD using Charlson and Elixhauser comorbidity indexes. RESULTS: The prevalence of PWD was 6.4% (353/5516). Patients receiving ASA had lower incidence of PWD (3.2% vs 8.5%, P < .0001) while having comparable rates of 30-day VTE (1.3% vs 1.4%, P = .722) and PJI at 6 months (1.8% vs 1.4%, P = .233) compared to those receiving Coumadin. Risk factors for PWD were diabetes (odds ratio [OR], 19.3; 95% confidence interval [CI], 11.8-23.2), rheumatoid arthritis (OR, 15.3; 95% CI, 10.8-17.2), morbid obesity (OR, 13.2; 95% CI, 9.7-17.5), chronic alcohol use (OR, 3.5; 95% CI, 1.8-5.5), hypothyroidism (OR, 1.9; 95% CI, 1.1-3.2), and Coumadin (OR, 1.7; 95% CI, 1.2-2.2). CONCLUSION: Use of ASA is associated with significantly lower rates of PWD after THA and TKA when compared to Coumadin while being equally efficacious at preventing VTE. Coumadin was found to be an independent risk factor for PWD.


Subject(s)
Arthroplasty, Replacement, Hip , Venous Thromboembolism , Arthroplasty, Replacement, Hip/adverse effects , Aspirin/adverse effects , Drainage , Humans , Postoperative Complications , Retrospective Studies , Risk Factors , Venous Thromboembolism/epidemiology , Venous Thromboembolism/etiology , Venous Thromboembolism/prevention & control , Warfarin/adverse effects
10.
Physiother Theory Pract ; 36(1): 176-185, 2020 Jan.
Article in English | MEDLINE | ID: mdl-29897271

ABSTRACT

Design: Retrospective analysis of routinely collected clinical data. Objective: This study modeled the recovery in knee flexion and extension range of motion (ROM) over 1 year after total knee replacement (TKR). Background: Recovery after TKR has been characterized for self-reported pain and functional status. Literature describing target knee ROM at different follow-up periods after TKR is scarce. Methods: Data were extracted for patients who had undergone TKR at a tertiary care hospital at 2, 8, 12, 26, and 52 weeks after TKR. A linear mixed-effects growth model was constructed that investigated the following covariates age, sex, pre-TKR range, body mass index, duration of symptoms, and their interaction with weeks post TKR. Results: Of the 559 patients included (age 64.8 ± 8.5 years), 370 were women and 189 were men. Knee ROM showed the greatest change during the first 12 weeks after TKR, plateauing by 26 weeks. For an average patient, knee flexion increased from approximately 100º 2 weeks post TKR to 117º 52 weeks post TKR. Knee extension increased from approximately 3º knee flexion 2 weeks post TKR to 1º flexion 52 weeks post TKR. Conclusions: The results showed that the maximum gains in knee ROM should be expected within the first 12 weeks with small changes occurring up to 26 weeks after TKR. In addition, age and presurgery knee ROM are associated with the gains in knee ROM and should be factored into the estimation of expected knee ROM at a given follow-up interval after TKR.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee/physiopathology , Osteoarthritis, Knee/surgery , Range of Motion, Articular , Aged , Female , Humans , Male , Middle Aged , Recovery of Function , Retrospective Studies , Time Factors
11.
HSS J ; 15(3): 261-268, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31624482

ABSTRACT

BACKGROUND: Individuals with advanced osteoarthritis (OA) of the knee experience significant impairments in balance and in essential physical functions such as walking and rising from a chair. There is limited evidence on valid outcome measures to capture these impairments. QUESTIONS/PURPOSES: We sought to examine the construct validity of three physical performance measures in patients with advanced knee OA: a gait speed (GS) test, the Short Physical Performance Battery (SPPB), and the Timed Up and Go (TUG) test. METHODS: We designed a cross-sectional clinical measurement study in which patients with advanced knee OA completed two self-reported measures: the Knee Injury and Osteoarthritis Outcome Score-Physical Function Shortform (KOOS-PS) and a four-part numeric pain rating scale (Q-NPRS). They were also administered the GS test, TUG test, and SPPB. Convergent and divergent construct validity were assessed by examining relationships between the GS test, the SPPB, the TUG test, the KOOS-PS, and the Q-NPRS and calculating Pearson correlation coefficients (r). The scores for the GS, TUG test, and SPPB were compared with established normative values for age-matched healthy controls. RESULTS: Forty-four subjects (mean age, 66.9 ± 8.1 years) participated in the study. The GS test showed low concordance with the SPPB component tests and the TUG test. The relationships between the physical performance measures and the self-reported measures were low. The scores for the GS test, TUG test, and SPPB in our sample were significantly worse when compared with age-matched normative values, indicating impairments in physical performance. CONCLUSION: These results advance the understanding of the validity of the GS test, TUG test, and SPPB in demonstrating the impairments in physical performance that patients with advanced knee OA experience in walking, balancing, and rising from a chair. Future research should examine the reproducibility and responsiveness of the GS test, TUG test, and SPPB in patients with advanced knee OA, in order to facilitate the integration of these measures into clinical practice.

12.
Arthroplast Today ; 5(3): 329-333, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31516977

ABSTRACT

BACKGROUND: Persistent wound drainage (PWD) is one of the major risk factors for periprosthetic joint infections (PJIs), arguably the most dreaded complication after total joint arthroplasty (TJA). The aim of this study was to identify the risk factors for PWD and provide a stepwise management protocol for it. METHODS: A retrospective review of 4873 TJAs was performed. After determining patients with PWD, a logistic regression model was designed to identify the risk factors using Charlson and Elixhauser comorbidity indexes. Finally, the protocol that was instituted for the management of PWD and its success rate was presented. RESULTS: The prevalence of PWD was 6.2% (302 of 4873). Of these, 196 did not require any surgical interventions, and drainage stopped with local wound care. 106 patients required surgical intervention, of which, 64 underwent superficial irrigation and debridement and 42 underwent deep irrigation and debridement with modular components exchange. Patients with PWD had significantly higher rates of PJI (odds ratio [OR]: 16.9; 95% confidence interval [CI]: 9.1-31.6). Risks factors were diabetes (OR: 21.2; 95% CI: 12.8-25.1), morbid obesity (OR: 17.3; 95% CI: 14.7-21.5), rheumatoid arthritis (OR: 14.2; 95% CI: 11.7-16.5), chronic alcohol use (OR: 4.3; 95% CI: 2.3-6.1), hypothyroidism (OR: 2.8; 95% CI: 1.3-4.2), and female gender (OR: 1.9; 95% CI: 1.1-2.2). CONCLUSIONS: Several modifiable risk factors of PWD were identified. Surgeons must be cognizant of these comorbidities and optimize patients' general health before an elective TJA. Our results demonstrated that PWD ceased in about 65% of the patients with local wound care measures alone. Patients with PWD were at substantially higher risk for PJI.

13.
Arch Bone Jt Surg ; 7(3): 211-219, 2019 May.
Article in English | MEDLINE | ID: mdl-31312677

ABSTRACT

Knee osteoarthritis (OA) affects the joint beyond just the articular cartilage. Specifically, magnetic resonance imaging-identified bone marrow lesions (BML) in the subchondral bone have both clinical and pathophysiological significance. Compared to joint space narrowing on traditional radiographs, the presence of BMLs has been better correlated with severity of clinical symptoms as well as clinical deterioration. Presence of a BML increases the likelihood for progression to a total knee arthroplasty by up to nine fold. Histochemical analysis of BMLs has shown increased levels of tumor necrosis factor-alpha, matrix metalloproteinases and substance P, thought to stimulate pain receptors in osteoarthritis. LEVEL OF EVIDENCE: V.

16.
Arthroplast Today ; 4(3): 343-347, 2018 Sep.
Article in English | MEDLINE | ID: mdl-30186919

ABSTRACT

BACKGROUND: Pulmonary embolism and deep vein thrombosis, together referred to as venous thromboembolism (VTE), are serious and potentially preventable complications after total hip arthroplasty and total knee arthroplasty. The aim of this study was to investigate the incidence of mortality after VTE events and assess the risk factors that are associated with it. METHODS: The Nationwide Inpatient Sample was used to estimate the total number of total hip arthroplasty, total knee arthroplasty, VTE events, and mortality using the International Classification of Diseases, Ninth Revision procedure codes from 2003 to 2012. Patients' demographics, Elixhauser, and Charlson comorbidity indices were used to identify the risk factors associated with in-hospital VTEs and mortality. RESULTS: A total of 1,805,621 THAs and TKAs were included. The overall rate of VTE was 0.93%. The in-hospital mortality rate among patients with VTEs was 7.1% vs 0.30% in patients without VTEs (P-value < .0001). The risk factors for mortality after VTE events in descending order were as follows: hypercoagulable state (odds ratio [OR]: 5.3, 95% confidence interval [CI]: 3.6-5.8), metastatic cancer (OR: 5.2, 95% CI: 3.3-5.6), myocardial infarction (OR: 4.2, 95% CI: 2.3-4.7), peripheral vascular disease (OR: 3.6, 95% CI: 3.2-4.0), cardiac arrhythmias (OR: 3.2, 95% CI: 1.6-4.3), advanced age (OR: 3.1, 95% CI: 2.3-3.7), electrolyte disorders (OR: 3.1, 95% CI: 2.2-3.6), pulmonary circulation disorders (OR: 2.9, 95% CI: 2.6-3.3), depression (OR: 2.8, 95% CI: 1.6-3.4), complicated diabetes (OR: 2.7, 95% CI: 2.1-3.2), weight loss (OR: 2.6, 95% CI: 2.2-3.3), renal failure (OR: 2.6, 95% CI: 1.7-3.5), chronic pulmonary disease (OR: 2.5, 95% CI: 1.3-3.1), valvular disease (OR: 2.4, 95% CI: 1.8-2.7), liver disease (OR: 1.7, 95% CI: 1.2-1.9), and obesity (OR: 1.6, 95% CI: 1.5-1.9). CONCLUSIONS: In-hospital VTE has a significant in-hospital mortality rate. Several of the identified risk factors in this study are modifiable preoperatively. We strongly urge the orthopaedic community to be cognizant of these risk factors and emphasize on optimizing patients' comorbidities before an elective arthroplasty.

17.
J Arthroplasty ; 33(4): 1076-1081, 2018 04.
Article in English | MEDLINE | ID: mdl-29223404

ABSTRACT

BACKGROUND: Image-based and imageless computer-assisted total knee arthroplasty (CATKA) has become increasingly popular. This study aims to compare outcomes, including perioperative complications and transfusion rate, between CATKA and conventional total knee arthroplasty (TKA), as well as between image-based and imageless CATKA. METHODS: Using the 9th revision of the International Classification of Diseases codes, we queried the Nationwide Inpatient Sample database from 2005 to 2011 to identify unilateral conventional TKA, image-based, and imageless CATKAs as well as in-hospital complications and transfusion rates. RESULTS: A total of 787,809 conventional TKAs and 13,246 CATKAs (1055 image-based and 12,191 imageless) were identified. The rate of CATKA increased 23.13% per year from 2005 to 2011. Transfusion rates in conventional TKA and CATKA cases were 11.73% and 8.20% respectively (P < .001) and 6.92% in image-based vs 8.27% in imageless (P = .023). Perioperative complications occurred in 4.50%, 3.47%, and 3.41% of cases after conventional, imageless, and imaged-based CATKAs, respectively. Using multivariate analysis, perioperative complications were significantly higher in conventional TKA compared to CATKA (odds ratio = 1.17, 95% confidence interval 1.03-1.33, P = .01). There was no significant difference between imageless and image-based CATKA (P = .34). Length of hospital stay and hospital charges were not significantly different between groups (P > .05). CONCLUSION: CATKA has low complication rates and may improve patient outcomes after TKA. CATKA, especially the image-based technique, may reduce in-hospital complications and transfusion without increasing hospital charges and length of hospital stay significantly. Large prospective studies with long follow-up are required to verify potential benefits of CATKA.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Blood Transfusion , Length of Stay , Surgery, Computer-Assisted/methods , Aged , Databases, Factual , Female , Geography , Hospitalization , Humans , International Classification of Diseases , Male , Middle Aged , Prospective Studies , Treatment Outcome
18.
J Knee Surg ; 30(6): 577-584, 2017 Jul.
Article in English | MEDLINE | ID: mdl-27894147

ABSTRACT

Much of the published works assessing the reliability of smartphone goniometer apps (SG) have poor generalizability since the reliability was assessed in healthy subjects. No research has established the values for standard error of measurement (SEM) or minimal detectable change (MDC) which have greater clinical utility to contextualize the range of motion (ROM) assessed using the SG. This research examined the test-retest reproducibility, concurrent validity, SEM, and MDC values for the iPhone goniometer app (i-Goni; June Software Inc., v.1.1, San Francisco, CA) in assessing knee ROM in patients with knee osteoarthritis or those after total knee replacement. A total of 60 participants underwent data collection which included the assessment of active knee ROM using the i-Goni and the universal goniometer (UG; EZ Read Jamar Goniometer, Patterson Medical, Warrenville, IL), knee muscle strength, and assessment of pain and lower extremity disability using quadruple numeric pain rating scale (Q-NPRS) and lower extremity functional scale (LEFS), respectively. Intraclass correlation coefficients (ICCs) were calculated to assess the reproducibility of the knee ROM assessed using the i-Goni and UG. Bland and Altman technique examined the agreement between these knee ROM. The SEM and MDC values were calculated for i-Goni assessed knee ROM to characterize the error in a single score and the index of true change, respectively. Pearson correlation coefficient examined concurrent relationships between the i-Goni and other measures. The ICC values for the knee flexion/extension ROM were superior for i-Goni (0.97/0.94) compared with the UG (0.95/0.87). The SEM values were smaller for i-Goni assessed knee flexion/extension (2.72/1.18 degrees) compared with UG assessed knee flexion/extension (3.41/1.62 degrees). Similarly, the MDC values were smaller for both these ROM for the i-Goni (6.3 and 2.72 degrees) suggesting smaller change required to infer true change in knee ROM. The i-Goni assessed knee ROM showed expected concurrent relationships with UG, knee muscle strength, Q-NPRS, and the LEFS. In conclusion, the i-Goni demonstrated superior reproducibility with smaller measurement error compared with UG in assessing knee ROM in the recruited cohort. Future research can expand the inquiry for assessing the reliability of the i-Goni to other joints.


Subject(s)
Arthrometry, Articular/instrumentation , Knee Joint/physiopathology , Osteoarthritis, Knee/physiopathology , Range of Motion, Articular , Smartphone , Aged , Arthroplasty, Replacement, Knee , Female , Humans , Lower Extremity , Male , Middle Aged , Muscle Strength , Reproducibility of Results
19.
Pain Pract ; 17(2): 197-207, 2017 02.
Article in English | MEDLINE | ID: mdl-27206564

ABSTRACT

BACKGROUND: Postoperative pain management protocols that use patient-controlled analgesia (PCA) can hinder mobility due to attached machinery and tubing. Immobility in the postoperative setting can increase complications, length of stay (LOS), and costs. Early and enhanced mobilization can reduce the cost of care while improving patient outcomes. A needle-free, compact, patient-activated, and portable fentanyl iontophoretic transdermal system (fentanyl ITS, IONSYS; The Medicines Company, Parsippany NJ) has been shown to provide comparable efficacy and tolerability to intravenous (IV) PCA morphine that promotes improved mobility. METHODS: This pooled analysis of 1,882 patients across three randomized, controlled trials compared fentanyl ITS to IV PCA morphine for postoperative pain management. Outcomes of patient mobility were assessed by a validated Patient Ease of Care Questionnaire that was given to patients, patients' nurses, and physical therapists involved in patient care. Safety was assessed via spontaneously reported treatment-emergent adverse events (TEAE). RESULTS: Fentanyl ITS significantly improved overall patient mobility, each mobility subscore (P < 0.0001) across all demographics (male/female; elderly/non-elderly; normal BMI/overweight/obese/morbidly obese) and surgery types, and was consistent across nurses and physical therapists mobility assessments. TEAEs were generally similar between the two groups. However, more patients reported an opioid-related TEAE with morphine IV PCA than with fentanyl IV PCA (P = 0.003). CONCLUSION: Due to improved mobility with fentanyl ITS, complications are expected to be less frequent than with IV PCA and epidural PCA. Incorporation of this strategy into postoperative pain management protocols may reduce LOS and total hospital costs.


Subject(s)
Analgesia, Patient-Controlled/instrumentation , Analgesia, Patient-Controlled/methods , Analgesics, Opioid/administration & dosage , Analgesics, Opioid/therapeutic use , Mobility Limitation , Morphine/administration & dosage , Morphine/therapeutic use , Postoperative Care/instrumentation , Postoperative Care/methods , Administration, Cutaneous , Administration, Intravenous , Adult , Aged , Aged, 80 and over , Analgesia, Epidural , Analgesia, Patient-Controlled/adverse effects , Analgesics, Opioid/adverse effects , Female , Fentanyl/administration & dosage , Fentanyl/therapeutic use , Humans , Iontophoresis , Male , Middle Aged , Morphine/adverse effects , Randomized Controlled Trials as Topic , Treatment Outcome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...