Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Sangre (Barc) ; 44(5): 357-63, 1999 Oct.
Article in Spanish | MEDLINE | ID: mdl-10618913

ABSTRACT

PURPOSE: The implementation of an in vivo assay to determine the biological activity of human recombinant erythropoietin (Hu-r EPO) is essential. The purpose of this study was to perform and optimize the conditions of an easy in vivo bioassay suitable for routine testing of quality control of Hu-r EPO preparations. MATERIAL AND METHODS: Normocythemic 8 weeks female mice treated with different Hu-r EPO doses were employed. The reticulocyte response was measured by flow cytometry and by visual count in a Neubauer cell count chamber, after selective red blood cell haemolysis. A unique subcutaneous injection with blood extraction 96 hours later was the schedule employed. The reticulocyte count measured by both methods was plotted against the log dose of Hu-r EPO. RESULTS: The dose-response curve obtained was linear between 5 and 160 UI/mouse and the doses chosen for future assays were 10, 30 and 90 UI/mouse. The use of at least 6 animals per dose and not less than 3 assays to obtain reliable limits according to international regulations is convenient. Thirty assays were performed in four different samples and were analyzed by parallel lines (3 + 3) relating the response with the log dose. The coefficient of correlation between both methods was 0.989, so they are equivalent. CONCLUSIONS: This method is suitable because fewer animals and bioassays are necessary to obtain fiducial limits according to international requirements. It is in agreement with the tendency to reduce the number of animals used for bioassay because ethical and economic reasons.


Subject(s)
Biological Assay/methods , Erythrocyte Count/drug effects , Erythropoietin/pharmacology , Reticulocyte Count/drug effects , Animals , Biological Assay/economics , Cell Separation , Dose-Response Relationship, Drug , Erythropoietin/administration & dosage , Erythropoietin/standards , Evaluation Studies as Topic , Female , Flow Cytometry , Humans , Injections, Subcutaneous , Mice , Quality Control , Recombinant Proteins , Reproducibility of Results , Sensitivity and Specificity
2.
Sangre (Barc) ; 43(3): 231-5, 1998 Jun.
Article in Spanish | MEDLINE | ID: mdl-9741232

ABSTRACT

A study was carried out to establish an appropriate method for streptokinase (SK) potency determination (biological assay) in order to fulfil the main function of the Instituto Nacional de Medicamentos respecting products marketed in Argentina. The potency of different commercial samples of SK was determined against the International Standard, and three internationally accepted methods were used for this purpose: fibrin plate, clot lysis and chromogenic method. The analysis of results suggests that the fibrin plate method is the least precise and reproducible. The clot lysis and chromogenic methods demonstrated great precision and reproducibility, giving a correlation coefficient of 0.99. It is concluded that both of these methods are best suited to determine potency of SK commercial products.


Subject(s)
Fibrinolytic Agents/pharmacology , Streptokinase/pharmacology , Animals , Cattle , Chromogenic Compounds/metabolism , Evaluation Studies as Topic , Fibrin/metabolism , Fibrinolysis/drug effects , Fibrinolytic Agents/analysis , Fibrinolytic Agents/standards , Oligopeptides/metabolism , Reference Standards , Reproducibility of Results , Sensitivity and Specificity , Streptokinase/analysis , Streptokinase/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...