Food Chem ; 177: 23-8, 2015 Jun 15.
Article in English | MEDLINE | ID: mdl-25660853

ABSTRACT

An improved sample preparation procedure for analysis of carcinogenic ethyl carbamate (EC) in wine by GC-MS-SIM is proposed. Differences over AOAC reference procedure were: (1) use of EC-d5 as internal standard instead of less similar propyl carbamate; (2) extraction by diethyl ether instead of more toxic dichloromethane, and (3) concentration by vacuum automated parallel evaporation instead of more time and work consuming rotary evaporation. Mean recovery was 104.4%, intraday precision was 6.7% (3.4 µg L(-)(1)) and 1.7% (88.5 µg L(-)(1)), regression coefficient was 0.999 in the linear working range of 3-89 µg L(-)(1), and limits of detection and quantification were 0.4 and 1.2 µg L(-)(1). Applicability was demonstrated by analysis (in triplicate) of 5 wine samples. EC concentration ranged from 5.2 ± 0.2 to 29.4 ± 1.5 µg L(-)(1). The analytical method is selective, accurate, repeatable, linear, and has similar method performance as the reference method along with the several mentioned advantages.


Subject(s)
Gas Chromatography-Mass Spectrometry/methods , Urethane/analysis , Wine/analysis