Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Interact Cardiovasc Thorac Surg ; 23(6): 861-868, 2016 12.
Article in English | MEDLINE | ID: mdl-27572616

ABSTRACT

OBJECTIVES: In high-risk patients with severe aortic stenosis, aortic valve replacement (AVR) with a sutureless Perceval prosthesis (SU-AVR) can be performed instead of conventional AVR or transcatheter aortic valve implantation. Little data are available regarding postoperative conduction disorders after SU-AVR. We aimed to determine the incidence and predictors of new-onset complete atrioventricular block (NO-AVB) requiring permanent cardiac stimulation following SU-AVR. METHODS: We studied consecutive patients who underwent SU-AVR between 2013 and 2015. Early patients underwent partial aortic decalcification and subannular valve implantation (standard technique), while later patients underwent complete/symmetrical decalcification and intra-annular valve deployment (modified technique). Predictive baseline and procedural variables and electrocardiographic parameters were identified using a logistic regression model. RESULTS: We included 140 patients (mean age, 78 ± 6.5 years; mean Log EuroSCORE II, 8.9 ± 10%; 28.6% concomitant myocardial revascularization). The most common postoperative conduction disturbances were LBBB (25%), NO-AVB (12.1%) and first-degree atrioventricular block (AVB) (7.9%). The incidence of NO-AVB was 61% lower with the modified versus the standard technique (P= 0.04). NO-AVB predominantly appeared within 24 h post-surgery, occurring >24 h post-surgery in only 2 patients (both with baseline conduction defects). Independent predictors of NO-AVB included baseline left QRS axis deviation (LaQD; P= 0.03), first-degree AVB (P< 0.01) and standard surgical technique (P= 0.02). CONCLUSIONS: NO-AVB is a frequent complication following SU-AVR, and its incidence strongly depends on the surgical technique. Baseline first-degree AVB and LaQD independently predict NO-AVB and should be considered when deciding the duration of postoperative electrocardiographic monitoring.


Subject(s)
Aortic Valve Stenosis/surgery , Atrioventricular Block/epidemiology , Atrioventricular Block/therapy , Heart Valve Prosthesis Implantation/adverse effects , Pacemaker, Artificial , Aged , Aged, 80 and over , Electrocardiography , Female , Heart Conduction System/physiopathology , Heart Valve Prosthesis , Humans , Incidence , Logistic Models , Male , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...