Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Language
Publication year range
1.
PLoS One ; 14(1): e0211207, 2019.
Article in English | MEDLINE | ID: mdl-30689658

ABSTRACT

Clinical flow cytometry is a reliable methodology for whole blood cell phenotyping for different applications. The BD FACSLyric™ system comprises a flow cytometer available in different optical configurations, BD FACSuite™ Clinical software, and optional BD FACS™ Universal Loader. BD FACSuite Clinical software used with BD™ FC Beads and BD CS&T Beads enable universal setup for performance QC, instrument control, data acquisition/storage, online/offline data analysis, and instrument standardization. BD Biosciences sponsored the clinical evaluation of the BD FACSLyric 10-color configuration at seven clinical sites using delinked and de-identified blood specimens from HIV-infected and uninfected subjects to enumerate T-, B-, and NK-lymphocytes with the BD Multitest™ reagents (BD Multitest IMK kit and BD Multitest 6-color TBNK). Samples were analyzed on the BD FACSLyric system with BD FACSuite Clinical software, and on the BD FACSCanto™ II system with BD FACSCanto clinical software and BD FACS 7-Color Setup beads. For equivalency between methods, data (n = 362) were analyzed with Deming regression for absolute count and percentage of lymphocytes. Results gave R2 ≥0.98, with slope values ≥0.96, and slope ranges between 0.90-1.05. The percent (%) bias values were <10% for T- and NK cells and <15% for B- cells. The between-site (n = 4) total precision was tested for 5 days (2 runs/day), and gave %coefficient of variation below 10% for absolute cell counts. The stability claims were confirmed (n = 186) for the two BD Multitest reagents. The reference intervals were re-established in male and female adults (n = 134). The analysis by gender showed statistically significant differences for CD3+ and CD4+ T-cell counts and %CD4. In summary, the BD FACSLyric and the BD FACSCanto II systems generated comparable measurements of T-, B-, and NK-cells using BD Multitest assays.


Subject(s)
B-Lymphocytes/cytology , Cell Count/methods , Killer Cells, Natural/cytology , T-Lymphocytes/cytology , CD4-Positive T-Lymphocytes/cytology , Cell Count/standards , Flow Cytometry , HIV Infections/blood , HIV Infections/diagnosis , HIV Infections/immunology , Humans , Reagent Kits, Diagnostic , Reference Standards , Reproducibility of Results
2.
Open AIDS J ; 11: 76-90, 2017.
Article in English | MEDLINE | ID: mdl-29290885

ABSTRACT

BACKGROUND: The BD FACSPresto™ system uses capillary and venous blood to measure CD4 absolute counts (CD4), %CD4 in lymphocytes, and hemoglobin (Hb) in approximately 25 minutes. CD4 cell count is used with portable CD4 counters in resource-limited settings to manage HIV/AIDS patients. A method comparison was performed using capillary and venous samples from seven clinical laboratories in five countries. The BD FACSPresto system was assessed for variability between laboratory, instrument/operators, cartridge lots and within-run at four sites. METHODS: Samples were collected under approved voluntary consent. EDTA-anticoagulated venous samples were tested for CD4 and %CD4 T cells using the gold-standard BD FACSCalibur™ system, and for Hb, using the Sysmex® KX-21N™ analyzer. Venous and capillary samples were tested on the BD FACSPresto system. Matched data was analyzed for bias (Deming linear regression and Bland-Altman methods), and for concordance around the clinical decision point. The coefficient of variation was estimated per site, instrument/operator, cartridge-lot and between-runs. RESULTS: For method comparison, 93% of the 720 samples were from HIV-positive and 7% from HIV-negative or normal subjects. CD4 and %CD4 T cells venous and capillary results gave slopes within 0.96-1.05 and R2 ≥0.96; Hb slopes were ≥1.00 and R2 ≥0.89. Variability across sites/operators gave %CV <5.8% for CD4 counts, <1.9% for %CD4 and <3.2% for Hb. The total %CV was <7.7% across instrument/cartridge lot. CONCLUSION: The BD FACSPresto system provides accurate, reliable, precise CD4/%CD4/Hb results compared to gold-standard methods, irrespective of venous or capillary blood sampling. The data showed good agreement between the BD FACSPresto, BD FACSCalibur and Sysmex systems.

3.
PLoS One ; 11(8): e0157939, 2016.
Article in English | MEDLINE | ID: mdl-27483008

ABSTRACT

BACKGROUND: The BD FACSPresto™ Near-Patient CD4 Counter was developed to expand HIV/AIDS management in resource-limited settings. It measures absolute CD4 counts (AbsCD4), percent CD4 (%CD4), and hemoglobin (Hb) from a single drop of capillary or venous blood in approximately 23 minutes, with throughput of 10 samples per hour. We assessed the performance of the BD FACSPresto system, evaluating accuracy, stability, linearity, precision, and reference intervals using capillary and venous blood at KEMRI/CDC HIV-research laboratory, Kisumu, Kenya, and precision and linearity at BD Biosciences, California, USA. METHODS: For accuracy, venous samples were tested using the BD FACSCalibur™ instrument with BD Tritest™ CD3/CD4/CD45 reagent, BD Trucount™ tubes, and BD Multiset™ software for AbsCD4 and %CD4, and the Sysmex™ KX-21N for Hb. Stability studies evaluated duration of staining (18-120-minute incubation), and effects of venous blood storage <6-24 hours post-draw. A normal cohort was tested for reference intervals. Precision covered multiple days, operators, and instruments. Linearity required mixing two pools of samples, to obtain evenly spaced concentrations for AbsCD4, total lymphocytes, and Hb. RESULTS: AbsCD4 and %CD4 venous/capillary (N = 189/ N = 162) accuracy results gave Deming regression slopes within 0.97-1.03 and R2 ≥0.96. For Hb, Deming regression results were R2 ≥0.94 and slope ≥0.94 for both venous and capillary samples. Stability varied within 10% 2 hours after staining and for venous blood stored less than 24 hours. Reference intervals results showed that gender-but not age-differences were statistically significant (p<0.05). Precision results had <3.5% coefficient of variation for AbsCD4, %CD4, and Hb, except for low AbsCD4 samples (<6.8%). Linearity was 42-4,897 cells/µL for AbsCD4, 182-11,704 cells/µL for total lymphocytes, and 2-24 g/dL for Hb. CONCLUSIONS: The BD FACSPresto system provides accurate, precise clinical results for capillary or venous blood samples and is suitable for near-patient CD4 testing. TRIAL REGISTRATION: ClinicalTrials.gov NCT02396355.


Subject(s)
CD4 Lymphocyte Count/methods , HIV Infections/blood , Adolescent , Adult , Aged , CD4-Positive T-Lymphocytes/immunology , Child , Child, Preschool , Female , Flow Cytometry/methods , HIV Infections/immunology , Humans , Kenya/epidemiology , Male , Middle Aged , Sensitivity and Specificity , Young Adult
4.
Cytotherapy ; 16(11): 1558-1574, 2014 Nov.
Article in English | MEDLINE | ID: mdl-24927716

ABSTRACT

BACKGROUND AIMS: Evaluation of the BD Stem Cell Enumeration Kit was conducted at four clinical sites with flow cytometry CD34(+) enumeration to assess agreement between two investigational methods: (i) the BD FACSCanto II and BD FACSCalibur systems and (ii) the predicate method (Beckman Coulter StemKit and StemTrol, Immunotech SAS, Beckman Coulter, Marseille Cedex 9, France). METHODS: Leftover and delinked specimens (n = 1032) from clinical flow cytometry testing were analyzed on the BD FACSCanto II (n = 918) and BD FACSCalibur (n = 905) in normal and mobilized blood, frozen and thawed bone marrow and leucopheresis and cord blood anticoagulated with citrate phosphate dextrose, anticoagulant citrate dextrose-solution A, heparin and ethylenediaminetetraacetate, alone or in combination. Fresh leucopheresis analysis addressed site equivalency for sample preparation, testing and analysis. RESULTS: The mean relative bias showed agreement within predefined parameters for the BD FACSCanto II (-2.81 to 4.31 ±7.1) and BD FACSCalibur (-2.69 to 5.2 ±7.9). Results are reported as absolute and relative differences compared with the predicate for viable CD34(+), percentage of CD34(+) in CD45(+) and viable CD45(+) populations (or gates). Bias analyses of the distribution of the predicate low, mid and high bin values were done using BD FACSCanto II optimal gating and BD FACSCalibur manual gating for viable CD34(+), percentage of CD34(+) in CD45(+) and viable CD45(+). Bias results from both investigational methods show agreement. Deming regression analyses showed a linear relationship with R(2) > 0.92 for both investigational methods. DISCUSSION: In conclusion, the results from both investigational methods demonstrated agreement and equivalence with the predicate method for enumeration of absolute viable CD34(+), percentage of viable CD34(+) in CD45(+) and absolute viable CD45(+) populations.


Subject(s)
Antigens, CD34/metabolism , Flow Cytometry/methods , Stem Cell Transplantation , Stem Cells/cytology , Antigens, CD34/immunology , Cell Count , Cell Lineage/genetics , Fetal Blood/cytology , Fetal Blood/immunology , Flow Cytometry/instrumentation , Humans , Stem Cells/immunology
5.
Arch. med. res ; 27(3): 265-73, 1996. ilus, tab
Article in English | LILACS | ID: lil-200324

ABSTRACT

In order to understand the neuronal mechanisms involved in acute and chronic pain, we studied the thalamic and cortical control action, which allows the suppression of the neuronal responses to noxious stimulation. As an experimental pain model we used carrageenin injected in the paw of male Wistar rats. The tonic facilitatory cortical control on centralis lateralis thalamic nuclei (CL) activity is described at different times after carrgeenin-produced inflammation. Simultaneous extracellular unit recordings were carried out at CL and medial prefrontal cortex (PCx) cells in anesthetized male Wistar rats. The PCx control was tested by blocking in a transient and reversible manner, using the cortical spreading depression (CSD). Carrageenin injection (1 percent; 0.2 ml) into the plantar surface of the right hind paw, and the influence of Lidocaine (2 percent; 0.2 ml) applied in the inflamed paw, was tested on unit activity in PCx and CL cells. Thalamic cells recorded in acute and subacute stages (24-72 h aftercarrageenin administration) were activated by tactile, light pressure and joint movement stimulation yielded before the injection. After carrageenin, the thalamic cells displayed spontaneous high frequency burst discharges, also presenting a progressive and significant increase (p < 0.001, ANOVA test) of their spontaneous firing when rate when compared with control cell activity. Lidocaine reduced the enhanced activity induced by carrageenin in thalamic neurones (p < 0.001, Student t test). In PCx neurones were also recorded in acute and subacute stages. Cortical cells from acute and subacute group were activated by nociceptive and non-nociceptives stimulation. In acute stage, cortical cells increased their firing rate after carrageenin and we could not observe modifications upon their firing rate due to Lidocaine. The CSD blocked all cortical activity in acute subacute stages. During the CSDs, overall thalamic activity was suppressed in neurones from acute (91 percent) and subacute (87 percent) stages. The blockage was observed when the propagated weve produced by CSD arrived into the medial prefrontal cortex. the CSD also suppressed the PCx and the CL noxious responses evoked by pressure in the receptive field. This study show the tonic facilitatory control of the PCx upon intralaminar thalamic noxious responses, during acute and subsacute stages of carrageenin produced inflammation. In the literature, it has been proposed that the CL thalamic...


Subject(s)
Rats , Animals , Carrageenan/pharmacokinetics , Electrophysiology/methods , Pain/physiopathology , Rats, Wistar/physiology , Thalamus/physiology , Urethane
6.
Bol. estud. méd. biol ; 37(1/2): 63-8, ene.-jul. 1989. ilus
Article in English | LILACS | ID: lil-88617

ABSTRACT

We report the effects exertec by the cortex upon the intralaminar thalamic nuclei, as revealed by blockade of the cortex with spreading depression in awake rats. Extracellular recordings of spontaneuous activity were made simultaneusly at thalamic and cortical sites. The effect of peripheral receptive field stimulation was to decrease activity of intralaminar thalamic cells. Cortical recordings revealed the cortical regions affected by spreading depression. Two type of cells were identified depending on the changes in their sensorial responses during the cortical spreading depression propagation. The first exhibited a tonic facilitating cortical control when the cortical spreading depression was located at a 8.0 to 10.0. The second type exhibited a disappearance of the sensorial responses when cortical spreadinf depression was a located at 4.0 to a 8.0 and also displayed the tonic facilitating control. This indicated that two different identifies cortical regions influenced the thalamic activity


Subject(s)
Rats , Animals , Cerebral Cortex , Thalamus
SELECTION OF CITATIONS