Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Indian J Med Microbiol ; 33 Suppl: 143-8, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25657135

ABSTRACT

AIM: To investigate if any mutations in hepatitis C virus (HCV) internal ribosome entry site (IRES) can inhibit the translation of viral polyprotein. MATERIALS AND METHODS: A 26-year-old male patient infected with HCV 10 years ago was followed up. After 9 years of chronic infection. The patient had managed to resolve the infection for a period of 9 months, after which the patient experienced a viral recurrence characterized by high viral load and diverse HCV quasispecies. The IRES structures of the viral strains that disappeared were comparable with those that are currently active using structural mutational analysis. RESULTS: A novo mutational position 254 combined with a rarely observed mutation at position 253 in the stem of the IIId subdomain were observed and the new conformation had an octa-apical loop (AGUGUUGG) and a shift in the 3 ` GU from the loop to the stem. CONCLUSIONS: These mutations were found to be highly deleterious, and they affected the direct binding of the IIId loop to the 40S ribosomal subunit with a subsequent inhibition of translation of viral polyprotein and clearance of the virus.


Subject(s)
Hepacivirus/genetics , Hepatitis C, Chronic/virology , Inverted Repeat Sequences , Nucleic Acid Conformation , RNA, Viral/chemistry , RNA, Viral/genetics , 5' Untranslated Regions , Adolescent , Base Sequence , Consensus Sequence , Enzyme-Linked Immunosorbent Assay , Hepacivirus/immunology , Hepatitis C, Chronic/diagnosis , Hepatitis C, Chronic/immunology , Humans , Male , Molecular Sequence Data , Reverse Transcriptase Polymerase Chain Reaction , Sequence Alignment , Viral Load , Viremia
2.
Article in English | MEDLINE | ID: mdl-24109779

ABSTRACT

Fontan procedure is one of the common surgical treatments of congenital heart diseases. Patients with Fontan circulation have single ventricle in the systemic circulation with the total cavopulmonary connection. We have been developing a pulmonary circulatory assist device using shape memory alloy fibers for Fontan circulation with total cavopulmonary connection. It consisted of the shape memory alloy fibers, the diameter of which are 100 µm. The fibers could wrap the ePTFE conduit for Fontan TCPC connection from the outside. We designed the sequential motion control system for sophisticated pulmonary hemodynamics by the pulsatile flow generation. In order to achieve pulsatile flow assistance in pulmonary arterial system, we fabricated a mechanical structure by sequential contraction of shape memory alloy fibers. Then, we developed a sequential contraction controller for the assist system, which could reproduce the wall contractile velocity at 6.0 to 20.0 cm/sec. We examined hemodynamic characteristic of its function using a mock circulatory system, which consisted of two overflow tanks representing venous and pulmonary arterial pressures in Fontan circulation. As a result, the pulmonary circulation assist device with sequential contraction could achieve effective promotion of the pulsatility in pulmonary arterial flow.


Subject(s)
Fontan Procedure/instrumentation , Heart Defects, Congenital/surgery , Cardiac Surgical Procedures/instrumentation , Child , Heart Defects, Congenital/physiopathology , Heart Ventricles/surgery , Hemodynamics , Humans , Infusion Pumps, Implantable , Myocardial Contraction , Pulmonary Artery/physiopathology , Pulmonary Artery/surgery , Pulmonary Circulation , Pulsatile Flow
3.
Article in English | MEDLINE | ID: mdl-22256284

ABSTRACT

Total cavopulmonary connection (TCPC) is commonly applied for the surgical treatment of congenital heart disease such as single ventricle in pediatric patients. Patients with no ventricle in pulmonary circulation are treated along with Fontan algorithm, in which the systemic venous return is diverted directly to the pulmonary artery without passing through subpulmonary ventricle. In order to promote the pulmonary circulation after Fontan procedure, we developed a newly designed pulmonary circulatory assist device by using shape memory alloy fibers. We developed a pulmonary circulatory assist device as a non-blood contacting mechanical support system in pediatric patients with TCPC. The device has been designed to be installed like a cuff around the ePTFE TCPC conduit, which can contract from outside. We employed a covalent type functional anisotropic shape memory alloy fiber (Biometal, Toki Corporation, Tokyo Japan) as a servo actuator of the pulmonary circulatory assist device. The diameter of this fiber was 100 microns, and its contractile frequency was 2-3 Hz. Heat generation with electric current contracts these fibers and the conduit. The maximum contraction ratio of this fiber is about 7% in length. In order to extend its contractile ratio, we fabricated and installed mechanical structural units to control the length of fibers. In this study, we examined basic contractile functions of the device in the mock system. As a result, the internal pressure of the conduit increased to 63 mmHg by the mechanical contraction under the condition of 400 msec-current supply in the mock examination with the overflow tank of 10 mmHg loading.


Subject(s)
Alloys/chemistry , Fontan Procedure/instrumentation , Heart-Assist Devices , Pulmonary Circulation/physiology , Child , Equipment Design , Humans , Mechanical Phenomena , Pressure
SELECTION OF CITATIONS
SEARCH DETAIL
...