Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Am Coll Emerg Physicians Open ; 3(5): e12792, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36187504

ABSTRACT

Introduction: Health equity for all patients is an important characteristic of an effective healthcare system. Bias has the potential to create inequities. In this study, we examine emergency department (ED) throughput and care measures for sex-based differences, including metrics such as door-to-room (DTR) and door-to-healthcare practitioner (DTP) times to look for potential signs of systemic bias. Methods: We conducted an observational cohort study of all adult patients presenting to the ED between July 2015 and June 2017. We collected ED operational, throughput, clinical, and demographic data. Differences in the findings for male and female patients were assessed using Poisson regression and generalized estimating equations (GEEs). A priori, a clinically significant time difference was defined as 10 min. Results: A total of 106,011 adult visits to the ED were investigated. Female patients had 8-min longer median length-of-stay (LOS) than males (P < 0.01). Females had longer DTR (2-min median difference, P < 0.01), and longer DTP (5-min median difference, P < 0.01). Females had longer median door-to-over-the-counter analgesia time (84 vs. 80, P = 0.58), door-to-advanced analgesia (95 vs. 84, P < 0.01), door-to-PO (by mouth) ondansetron (70 vs. 62, P = 0.02), and door-to-intramuscular/intravenous antiemetic (76 vs. 69, P = 0.02) times compared with males. Conclusion: Numerous statistically significant differences were identified in throughput and care measures-mostly these differences favored male patients. Few of these comparisons met our criteria for clinical significance.

2.
Biomed Opt Express ; 12(8): 4637-4650, 2021 08 01.
Article in English | MEDLINE | ID: mdl-34513214

ABSTRACT

Rapid, sensitive, and selective detection of nucleic acid biomarkers for health diagnostic applications becomes feasible for point of care scenarios when the detection instrument is inexpensive, simple, and robust. Here, we report the design, implementation, and characterization of a point of care instrument for photonic resonator absorption microscopy (PRAM) that takes advantage of resonant optical coupling between plasmonic gold nanoparticle tags and a photonic crystal (PC) surface. Matching the PC resonant wavelength to the gold nanoparticle's surface plasmon wavelength generates localized and efficient quenching of the PC resonant reflection intensity, resulting in the ability to clearly detect and count individual gold nanoparticles when they are captured on the PC surface. Surface-captured nanoparticles are observed by illuminating the PC at normal incidence with polarized light from a low-intensity red LED, and recording of PC reflected intensity on an inexpensive CMOS image sensor. A contrast limited adaptive histogram equalization (CLAHE) image processing algorithm was applied to derive counts of captured nanoparticles. The instrument is utilized in the context of an activate capture + digital counting (AC + DC) assay for a specific miRNA sequence, using nucleic acid toehold probes applied to gold nano-urchin (AuNU) nanoparticles to achieve 160 aM detection limits in a 30 min. assay.

SELECTION OF CITATIONS
SEARCH DETAIL
...