1.
Circ Heart Fail ; 13(6): e006552, 2020 06.
Article in English | MEDLINE | ID: mdl-32498623

ABSTRACT

BACKGROUND: Ex situ heart perfusion (ESHP) preserves the donated heart in a perfused, beating condition preventing cold storage-related ischemia and provides a platform to evaluate myocardial viability during preservation. However, myocardial function declines gradually during ESHP. Extracorporeal circulation systems are associated with the induction of systemic inflammatory and stress responses. Our aim was to evaluate the incidence of inflammation and induction of endoplasmic reticulum stress responses during an extended period of ESHP. METHODS: Cardiac function, myocardial tissue injury, markers of inflammation, oxidative stress, and endoplasmic reticulum stress were assessed in healthy pig hearts, perfused for 12 hours either in nonworking mode (non-WM=7) or working mode (WM, n=6). RESULTS: Cardiac function declined during ESHP but was significantly better preserved in the hearts perfused in WM (median 11-hour cardiac index/1-hour cardiac index: WM=27% versus non-WM=9.5%, P=0.022). Myocardial markers of endoplasmic reticulum stress were expressed higher in ESHP hearts compared with in vivo samples. The proinflammatory cytokines and oxidized low-density lipoprotein significantly increased in the perfusate throughout the perfusion in both perfusion groups. The left ventricular expression of the cytokines and malondialdehyde was induced in non-WM, whereas it was not different between WM and in vivo. CONCLUSIONS: Myocardial function declines during ESHP regardless of perfusion mode. However, ESHP in WM may lead to superior preservation of myocardial function and viability. Both inflammation and endoplasmic reticulum stress responses are significantly induced during ESHP and may contribute to the myocardial functional decline, representing a potential therapeutic target to improve the clinical donor heart preservation.


Subject(s)
Endoplasmic Reticulum Stress , Inflammation/metabolism , Myocardium/metabolism , Oxidative Stress , Perfusion/adverse effects , Animals , Cytokines/metabolism , Female , Inflammation/immunology , Inflammation/pathology , Inflammation/physiopathology , Inflammation Mediators/metabolism , Isolated Heart Preparation , Lipoproteins, LDL/metabolism , Malondialdehyde/metabolism , Myocardium/immunology , Myocardium/pathology , Sus scrofa , Time Factors , Tissue Survival , Ventricular Function, Left
2.
Ann Thorac Surg ; 108(2): 499-507, 2019 08.
Article in English | MEDLINE | ID: mdl-30872100

ABSTRACT

BACKGROUND: Myocardial function declines in a time-dependent fashion during ex situ heart perfusion. Cell death and metabolic alterations may contribute to this phenomenon, limiting the safe perfusion period and the potential of ex situ heart perfusion to expand the donor pool. Our aim was to investigate the etiology of myocardial functional decline in ex situ perfused hearts. METHODS: Cardiac function, apoptosis, effectors and markers of cell death, and metabolic function were assessed in healthy pig hearts perfused for 12 hours. These hearts were perfused in nonworking mode or working mode. RESULTS: Cardiac function declined during ex situ heart perfusion regardless of perfusion mode but was significantly better preserved in the hearts perfused in working mode (11-hour cardiac index/1-hour cardiac index: working mode, 33%; nonworking mode, 10%; p = 0.025). The rate of apoptosis was higher in the ex situ perfused hearts compared with in vivo samples (apoptotic cells: in vivo, 0.13%; working mode, 0.54%; nonworking mode, 0.88%; p < 0.001), but the absolute values were low and out of proportion to the decline in function in either group. Myocardial dysfunction at the end of the perfusion interval was partially rescued by delivery of a pyruvate bolus. CONCLUSIONS: A significant decline in myocardial function occurs over time in hearts preserved ex situ that is out of proportion to the magnitude of myocyte cell death present in dysfunctional hearts. Alterations in myocardial substrate utilization during prolonged ex situ heart perfusion may contribute to this phenomenon and represent an avenue to improve donor heart preservation.


Subject(s)
Coronary Circulation/physiology , Coronary Vessels/physiopathology , Heart Transplantation/methods , Myocardial Ischemia/physiopathology , Myocardium/metabolism , Organ Preservation/methods , Perfusion/adverse effects , Animals , Apoptosis , Biomarkers/blood , Coronary Vessels/pathology , Disease Models, Animal , Female , Myocardial Ischemia/metabolism , Myocardial Ischemia/pathology , Myocardium/pathology , Swine , Troponin I/blood
3.
J Vis Exp ; (143)2019 01 12.
Article in English | MEDLINE | ID: mdl-30688296

ABSTRACT

The current standard method for organ preservation (cold storage, CS), exposes the heart to a period of cold ischemia that limits the safe preservation time and increases the risk of adverse post-transplantation outcomes. Moreover, the static nature of CS does not allow for organ evaluation or intervention during the preservation interval. Normothermic ex situ heart perfusion (ESHP) is a novel method for preservation of the donated heart that minimizes cold ischemia by providing oxygenated, nutrient-rich perfusate to the heart. ESHP has been shown to be non-inferior to CS in the preservation of standard-criteria donor hearts and has also facilitated the clinical transplantation of the hearts donated after the circulatory determination of death. Currently, the only available clinical ESHP device perfuses the heart in an unloaded, non-working state, limiting assessments of myocardial performance. Conversely, ESHP in working mode provides the opportunity for comprehensive evaluation of cardiac performance by assessment of functional and metabolic parameters under physiologic conditions. Moreover, earlier experimental studies have suggested that ESHP in working mode may result in improved functional preservation. Here, we describe the protocol for ex situ perfusion of the heart in a large mammal (porcine) model, which is reproducible for different animal models and heart sizes. The software program in this ESHP apparatus allows for real-time and automated control of the pump speed to maintain desired aortic and left atrial pressure and evaluates a variety of functional and electrophysiological parameters with minimal need for supervision/manipulation.


Subject(s)
Heart/physiology , Metabolism , Perfusion , Animals , Anti-Inflammatory Agents/pharmacology , Blood Gas Analysis , Electrocardiography , Heart/diagnostic imaging , Magnetic Phenomena , Models, Animal , Myocardium/metabolism , Pressure , Silicones , Swine , Ventricular Function