Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Exp Dent Res ; 6(2): 266-273, 2020 04.
Article in English | MEDLINE | ID: mdl-32026625

ABSTRACT

OBJECTIVES: This proof-of-principle, single-center, randomized, examiner-blind, crossover study compared two experimental polyvinyl acetate (PVA)-based denture adhesives (Test Adhesives 1 and 2) with a marketed reference polymethyl vinyl ether/maleic anhydride (PMV/MA)-based adhesive and no adhesive using incisal bite force area over baseline over 12 hr (AOB0-12 ) in participants with an at least moderately well-fitting complete maxillary denture. Previous in vitro studies suggested the experimental denture adhesives provided superior performance. MATERIALS AND METHODS: Participants were randomized to a treatment sequence such that each received each treatment once. Prior to treatment application (baseline) and at 0.5, 1, 3, 6, 9, and 12 hr following the application, participants bit on a force transducer until their maxillary denture dislodged. Between-treatment differences in AOB0-12 were analyzed using analysis of covariance. For study validity, the reference adhesive was compared with no adhesive. Participants were asked to rate sensory experiences and ease of denture removal. RESULTS: Twenty-three participants were included in the modified intent-to-treat population. Although Test Adhesives 1 and 2 had a higher mean AOB0-12 than no adhesive, differences were not statistically significant. No statistically significant difference was also found between the reference adhesive and no adhesive; hence, study validity was not attained. Participants did not report any clear differences between the test or reference adhesives in terms of taste or feel; however, dentures were easier to remove with the test adhesives versus reference. No treatment-related adverse events were reported. CONCLUSION: Neither the experimental PVA-based denture adhesives nor the PMV/MA-based reference product demonstrated a statistically significant difference in incisal bite force AOB0-12 compared with no adhesive. The reasons for these unexpected results is unclear; they suggest that findings of in vitro tests for denture adhesive performance are not always translated to in vivo performance (Clinicaltrials.gov: NCT02937870).


Subject(s)
Adhesives/administration & dosage , Bite Force , Denture Retention/methods , Denture, Complete , Adolescent , Adult , Aged , Aged, 80 and over , Cross-Over Studies , Female , Humans , Incisor , Male , Maxilla , Middle Aged , Polyvinyls/administration & dosage , Proof of Concept Study , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...