Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
2.
J Vasc Interv Radiol ; 33(2): 183-188, 2022 02.
Article in English | MEDLINE | ID: mdl-34700012

ABSTRACT

PURPOSE: To investigate the short-term results of single-session treatment of iliocaval and iliofemoral DVT using a single thrombectomy device. MATERIALS AND METHODS: This prospective pilot study analyzed patients with acute iliocaval or iliofemoral DVT treated in a single session using the JETi thrombectomy system. All analyses were performed on an intention-to-treat basis. The cohort consisted of 53 limbs in 47 patients (27 women), with a mean age of 57 years (range, 16-88 years). The primary safety and efficacy endpoints were freedom from major adverse events (MAEs) and reestablishment of unobstructed flow in a single session, respectively. RESULTS: The mean duration of symptoms was 8.5 days ± SD 9.2, with 10 patients (11 limbs, 21.3%) presenting with a symptom duration of >14 days. Twelve (25.5%) patients had thrombosis of the inferior vena cava and the iliofemoral segments. During the index procedure, unobstructed flow was reestablished in 47 of 53 (88.6%) limbs in 41 of 47 (87.2%) patients (primary endpoint) with no MAEs through 30 days. Overall, unobstructed flow was restored in 50 of 53 (94.3%) limbs and in 44 of 47 (93.6%) patients. CONCLUSIONS: Successful single-session treatment of patients with acute iliocaval and iliofemoral DVT is feasible with a high rate of efficacy and a low rate of adverse events. Such patients may be treated on an outpatient basis.


Subject(s)
Iliac Vein , Venous Thrombosis , Female , Femoral Vein/diagnostic imaging , Humans , Iliac Vein/diagnostic imaging , Middle Aged , Pilot Projects , Prospective Studies , Retrospective Studies , Thrombectomy , Thrombolytic Therapy/methods , Treatment Outcome , Vascular Patency , Venous Thrombosis/diagnostic imaging , Venous Thrombosis/therapy
3.
Innovations (Phila) ; 16(1): 26-33, 2021.
Article in English | MEDLINE | ID: mdl-33124923

ABSTRACT

Preoperative image-guided localization of lung nodules is necessary for successful intraoperative localization and resection. However, current localization techniques carry significant intraoperative disadvantages for surgeons. Articles were selected through multiple search engines using key search terms and reviewed to compare results, outcomes, advantages, limitations, and complications of various localization methods. Current methods utilize microcoils, hookwires, contrast media, dyes, cyanoacrylate, radiotracers, or fluorescence tracers, which are associated with many intraoperative disadvantages even when paired with other imaging modalities including computed tomography and bronchoscopy techniques. Novel technologies including robotic bronchoscopy, 4-hook anchor, SPiN Thoracic Navigation System, superDimension, Ion Endoluminal System, and the SCOUT system are reviewed including their advantages, which may change the future direction of minimal thoracoscopic surgery with potential to improve intraoperative accuracy and efficiency.


Subject(s)
Lung Neoplasms , Solitary Pulmonary Nodule , Surgeons , Bronchoscopy , Humans , Lung , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/surgery , Solitary Pulmonary Nodule/diagnostic imaging , Solitary Pulmonary Nodule/surgery , Thoracic Surgery, Video-Assisted
4.
Surg Innov ; 26(4): 469-472, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31027475

ABSTRACT

Background. Current techniques for localization and resection of lung nodules carry many intraoperative challenges for surgeons. This article proposes a new localization method for diagnosis and treatment of pulmonary nodules, which provides a navigational system for more accurate lung resection. Methods. We report the case of a 77-year-old female with a pulmonary nodule of the right lower lobe. A nonradioactive localization technology, known as SAVI SCOUT (Cianna Medical Inc, Aliso Viejo, CA), was placed by interventional radiology under computed tomography guidance preoperatively. Using the SCOUT Wire-Free Radar Localization System, the pulmonary nodule was robotically localized and resected. SCOUT removal was confirmed using the Trident Specimen Radiology System. The efficacy of this procedure was evaluated in terms of ease of use and procedure time by interventional radiology, surgical resection accuracy, diagnostic accuracy, simplicity, and ease to implement this technology in an existing hospital. Results. The SCOUT system allowed for the first reported case of successful SCOUT placement in lung tissue, targeted the pulmonary nodule intraoperatively, and facilitated accurate lung resection. Conclusions. The SCOUT system shows promising advancements in the ability to eliminate many challenges currently seen with lung nodule localization and resection.


Subject(s)
Lung Neoplasms/surgery , Radiography, Interventional/instrumentation , Robotic Surgical Procedures , Solitary Pulmonary Nodule/surgery , Tomography, X-Ray Computed , Aged , Female , Humans , Image-Guided Biopsy , Lung Neoplasms/diagnostic imaging , Positron-Emission Tomography , Solitary Pulmonary Nodule/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...