Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Pract ; 14(3): 946-953, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38804407

ABSTRACT

BACKGROUND: Arrhythmias in pregnancy are complex to manage due to the teratogenic effects of many antiarrhythmic drugs and the common use of ionizing radiation during catheter ablation procedures. Furthermore, pregnant women are extremely vulnerable and difficult to treat because of the progressive physical and hormonal changes that occur during the nine months of pregnancy. CASE PRESENTATION: In this case report, we describe a complex clinical case of a 34-year-old pregnant woman who was affected by an incessant right atrial tachycardia, with signs and symptoms of initial hemodynamic instability. This tachycardia was refractory to antiarrhythmic drugs, so a zero-fluoroscopy ablation was performed. The first procedure was complicated by cardiac tamponade, quickly resolved without further complications for the mother or the fetus. In the following days, a deep venous thrombosis occurred at the femoral venous access. After a few days, the patient underwent a second procedure that was successful and resulted in the restoration of a sinus rhythm. CONCLUSIONS: The management of this clinical case was complex both from a procedural and a clinical (cardiological and gynecological) point of view. Finally, the integration of the various skills led to an excellent result.

2.
Front Cardiovasc Med ; 9: 804424, 2022.
Article in English | MEDLINE | ID: mdl-35571172

ABSTRACT

Background: Awareness of radiation exposure risks associated to interventional cardiology procedures is growing. The availability of new technologies in electrophysiology laboratories has reduced fluoroscopy usage during arrhythmias ablations. The aim of this study was to describe procedures with and without X-Rays and to assess feasibility, safety, and short-term efficacy of zero fluoroscopy intervention in a high-volume center oriented to keep exposure to ionizing radiation as low as reasonably achievable. Methods: Cardiac catheter ablations performed in our hospital since January 2017 to June 2021. Results: A total of 1,853 procedures were performed with 1,957 arrhythmias treated. Rate of fluoroless procedures was 15.4% (285 interventions) with an increasing trend from 8.5% in 2017 to 22.9% of first semester 2021. The most frequent arrhythmia treated was atrial fibrillation (646; 3.6% fluoroless) followed by atrioventricular nodal reentrant tachycardia (644; 16.9% fluoroless), atrial flutter (215; 8.8% fluoroless), ventricular tachycardia (178; 17.4% fluoroless), premature ventricular contraction (162; 48.1% fluoroless), and accessory pathways (112; 31.3% fluoroless). Although characteristics of patients and operative details were heterogeneous among treated arrhythmias, use of fluoroscopy did not influence procedure duration. Moreover, feasibility and efficacy were 100% in fluoroless ablations while the rate of major complications was very low and no different with or without fluoroscopy (0.45 vs. 0.35%). Conclusion: Limiting the use of X-Rays is necessary, especially when the available technologies allow a zero-use approach. A lower radiation exposure may be reached, reducing fluoroscopy usage whenever possible during cardiac ablation procedures with high safety, full feasibility, and efficacy.

SELECTION OF CITATIONS
SEARCH DETAIL
...