Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 100
Filter
2.
J Am Coll Cardiol ; 83(11): 1042-1055, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38385929

ABSTRACT

BACKGROUND: Ventricular arrhythmia in hypertrophic cardiomyopathy (HCM) relates to adverse structural change and genetic status. Cardiovascular magnetic resonance (CMR)-guided electrocardiographic imaging (ECGI) noninvasively maps cardiac structural and electrophysiological (EP) properties. OBJECTIVES: The purpose of this study was to establish whether in subclinical HCM (genotype [G]+ left ventricular hypertrophy [LVH]-), ECGI detects early EP abnormality, and in overt HCM, whether the EP substrate relates to genetic status (G+/G-LVH+) and structural phenotype. METHODS: This was a prospective 211-participant CMR-ECGI multicenter study of 70 G+LVH-, 104 LVH+ (51 G+/53 G-), and 37 healthy volunteers (HVs). Local activation time (AT), corrected repolarization time, corrected activation-recovery interval, spatial gradients (GAT/GRTc), and signal fractionation were derived from 1,000 epicardial sites per participant. Maximal wall thickness and scar burden were derived from CMR. A support vector machine was built to discriminate G+LVH- from HV and low-risk HCM from those with intermediate/high-risk score or nonsustained ventricular tachycardia. RESULTS: Compared with HV, subclinical HCM showed mean AT prolongation (P = 0.008) even with normal 12-lead electrocardiograms (ECGs) (P = 0.009), and repolarization was more spatially heterogenous (GRTc: P = 0.005) (23% had normal ECGs). Corrected activation-recovery interval was prolonged in overt vs subclinical HCM (P < 0.001). Mean AT was associated with maximal wall thickness; spatial conduction heterogeneity (GAT) and fractionation were associated with scar (all P < 0.05), and G+LVH+ had more fractionation than G-LVH+ (P = 0.002). The support vector machine discriminated subclinical HCM from HV (10-fold cross-validation accuracy 80% [95% CI: 73%-85%]) and identified patients at higher risk of sudden cardiac death (accuracy 82% [95% CI: 78%-86%]). CONCLUSIONS: In the absence of LVH or 12-lead ECG abnormalities, HCM sarcomere gene mutation carriers express an aberrant EP phenotype detected by ECGI. In overt HCM, abnormalities occur more severely with adverse structural change and positive genetic status.


Subject(s)
Cardiomyopathy, Hypertrophic , Cicatrix , Humans , Prospective Studies , Cicatrix/pathology , Magnetic Resonance Imaging, Cine , Cardiomyopathy, Hypertrophic/diagnostic imaging , Cardiomyopathy, Hypertrophic/genetics , Electrocardiography , Hypertrophy, Left Ventricular/diagnosis , Magnetic Resonance Imaging
3.
Physiol Rep ; 12(3): e15940, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38346773

ABSTRACT

The pathogenesis of exercise intolerance and persistent fatigue which can follow an infection with the SARS-CoV-2 virus ("long COVID") is not fully understood. Cases were recruited from a long COVID clinic (N = 32; 44 ± 12 years; 10 (31%) men), and age-/sex-matched healthy controls (HC) (N = 19; 40 ± 13 years; 6 (32%) men) from University College London staff and students. We assessed exercise performance, lung and cardiac function, vascular health, skeletal muscle oxidative capacity, and autonomic nervous system (ANS) function. Key outcome measures for each physiological system were compared between groups using potential outcome means (95% confidence intervals) adjusted for potential confounders. Long COVID participant outcomes were compared to normative values. When compared to HC, cases exhibited reduced oxygen uptake efficiency slope (1847 (1679, 2016) vs. 2176 (1978, 2373) mL/min, p = 0.002) and anaerobic threshold (13.2 (12.2, 14.3) vs. 15.6 (14.4, 17.2) mL/kg/min, p < 0.001), and lower oxidative capacity, measured using near infrared spectroscopy (τ: 38.7 (31.9, 45.6) vs. 24.6 (19.1, 30.1) s, p = 0.001). In cases, ANS measures fell below normal limits in 39%. Long COVID is associated with reduced measures of exercise performance and skeletal muscle oxidative capacity in the absence of evidence of microvascular dysfunction, suggesting mitochondrial pathology. There was evidence of attendant ANS dysregulation in a significant proportion. These multisystem factors might contribute to impaired exercise tolerance in long COVID sufferers.


Subject(s)
COVID-19 , Post-Acute COVID-19 Syndrome , Male , Humans , Female , SARS-CoV-2 , COVID-19/metabolism , Muscle, Skeletal/metabolism , Exercise/physiology , Exercise Test/methods , Exercise Tolerance/physiology , Oxygen Consumption/physiology
4.
J Cardiovasc Magn Reson ; 25(1): 73, 2023 Dec 04.
Article in English | MEDLINE | ID: mdl-38044439

ABSTRACT

BACKGROUND: Electrocardiographic imaging (ECGI) generates electrophysiological (EP) biomarkers while cardiovascular magnetic resonance (CMR) imaging provides data about myocardial structure, function and tissue substrate. Combining this information in one examination is desirable but requires an affordable, reusable, and high-throughput solution. We therefore developed the CMR-ECGI vest and carried out this technical development study to assess its feasibility and repeatability in vivo. METHODS: CMR was prospectively performed at 3T on participants after collecting surface potentials using the locally designed and fabricated 256-lead ECGI vest. Epicardial maps were reconstructed to generate local EP parameters such as activation time (AT), repolarization time (RT) and activation recovery intervals (ARI). 20 intra- and inter-observer and 8 scan re-scan repeatability tests. RESULTS: 77 participants were recruited: 27 young healthy volunteers (HV, 38.9 ± 8.5 years, 35% male) and 50 older persons (77.0 ± 0.1 years, 52% male). CMR-ECGI was achieved in all participants using the same reusable, washable vest without complications. Intra- and inter-observer variability was low (correlation coefficients [rs] across unipolar electrograms = 0.99 and 0.98 respectively) and scan re-scan repeatability was high (rs between 0.81 and 0.93). Compared to young HV, older persons had significantly longer RT (296.8 vs 289.3 ms, p = 0.002), ARI (249.8 vs 235.1 ms, p = 0.002) and local gradients of AT, RT and ARI (0.40 vs 0.34 ms/mm, p = 0,01; 0.92 vs 0.77 ms/mm, p = 0.03; and 1.12 vs 0.92 ms/mm, p = 0.01 respectively). CONCLUSION: Our high-throughput CMR-ECGI solution is feasible and shows good reproducibility in younger and older participants. This new technology is now scalable for high throughput research to provide novel insights into arrhythmogenesis and potentially pave the way for more personalised risk stratification. CLINICAL TRIAL REGISTRATION: Title: Multimorbidity Life-Course Approach to Myocardial Health-A Cardiac Sub-Study of the MRC National Survey of Health and Development (NSHD) (MyoFit46). National Clinical Trials (NCT) number: NCT05455125. URL: https://clinicaltrials.gov/ct2/show/NCT05455125?term=MyoFit&draw=2&rank=1.


Subject(s)
Heart , Magnetic Resonance Imaging , Aged , Female , Humans , Male , Feasibility Studies , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Predictive Value of Tests , Reproducibility of Results , Adult , Middle Aged
5.
Sci Rep ; 13(1): 18966, 2023 11 03.
Article in English | MEDLINE | ID: mdl-37923787

ABSTRACT

Heart rate variability (HRV) is a cardiac autonomic marker with predictive value in cardiac patients. Ultra-short HRV (usHRV) can be measured at scale using standard and wearable ECGs, but its association with cardiovascular events in the general population is undetermined. We aimed to validate usHRV measured using ≤ 15-s ECGs (using RMSSD, SDSD and PHF indices) and investigate its association with atrial fibrillation, major adverse cardiac events, stroke and mortality in individuals without cardiovascular disease. In the National Survey for Health and Development (n = 1337 participants), agreement between 15-s and 6-min HRV, assessed with correlation analysis and Bland-Altman plots, was very good for RMSSD and SDSD and good for PHF. In the UK Biobank (n = 51,628 participants, 64% male, median age 58), after a median follow-up of 11.5 (11.4-11.7) years, incidence of outcomes ranged between 1.7% and 4.3%. Non-linear Cox regression analysis showed that reduced usHRV from 15-, 10- and 5-s ECGs was associated with all outcomes. Individuals with low usHRV (< 20th percentile) had hazard ratios for outcomes between 1.16 and 1.29, p < 0.05, with respect to the reference group. In conclusion, usHRV from ≤ 15-s ECGs correlates with standard short-term HRV and predicts increased risk of cardiovascular events in a large population-representative cohort.


Subject(s)
Cardiovascular Diseases , Electrocardiography , Humans , Male , Middle Aged , Female , Heart Rate/physiology , Electrocardiography/methods , Autonomic Nervous System/physiology , Cardiovascular Diseases/epidemiology , Proportional Hazards Models
6.
JMIR Form Res ; 7: e51507, 2023 Nov 24.
Article in English | MEDLINE | ID: mdl-37999935

ABSTRACT

BACKGROUND: Patients with chronic respiratory diseases and those in the postdischarge period following hospitalization because of COVID-19 are particularly vulnerable, and little is known about the changes in their symptoms and physiological parameters. Continuous remote monitoring of physiological parameters and symptom changes offers the potential for timely intervention, improved patient outcomes, and reduced health care costs. OBJECTIVE: This study investigated whether a real-time multimodal program using commercially available wearable technology, home-based Bluetooth-enabled spirometers, finger pulse oximeters, and smartphone apps is feasible and acceptable for patients with chronic respiratory diseases, as well as the value of low-burden, long-term passive data collection. METHODS: In a 3-arm prospective observational cohort feasibility study, we recruited 60 patients from the Royal Free Hospital and University College Hospital. These patients had been diagnosed with interstitial lung disease, chronic obstructive pulmonary disease, or post-COVID-19 condition (n=20 per group) and were followed for 180 days. This study used a comprehensive remote monitoring system designed to provide real-time and relevant data for both patients and clinicians. Data were collected using REDCap (Research Electronic Data Capture; Vanderbilt University) periodic surveys, Remote Assessment of Disease and Relapses-base active app questionnaires, wearables, finger pulse oximeters, smartphone apps, and Bluetooth home-based spirometry. The feasibility of remote monitoring was measured through adherence to the protocol, engagement during the follow-up period, retention rate, acceptability, and data integrity. RESULTS: Lowest-burden passive data collection methods, via wearables, demonstrated superior adherence, engagement, and retention compared with active data collection methods, with an average wearable use of 18.66 (SD 4.69) hours daily (77.8% of the day), 123.91 (SD 33.73) hours weekly (72.6% of the week), and 463.82 (SD 156.70) hours monthly (64.4% of the month). Highest-burden spirometry tasks and high-burden active app tasks had the lowest adherence, engagement, and retention, followed by low-burden questionnaires. Spirometry and active questionnaires had the lowest retention at 0.5 survival probability, indicating that they were the most burdensome. Adherence to and quality of home spirometry were analyzed; of the 7200 sessions requested, 4248 (59%) were performed. Of these, 90.3% (3836/4248) were of acceptable quality according to American Thoracic Society grading. Inclusion of protocol holidays improved retention measures. The technologies used were generally well received. CONCLUSIONS: Our findings provide evidence supporting the feasibility and acceptability of remote monitoring for capturing both subjective and objective data from various sources for respiratory diseases. The high engagement level observed with passively collected data suggests the potential of wearables for long-term, user-friendly remote monitoring in respiratory disease management. The unique piloting of certain features such as protocol holidays, alert notifications for missing data, and flexible support from the study team provides a reference for future studies in this field. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.2196/28873.

7.
Article in English | MEDLINE | ID: mdl-37831014

ABSTRACT

BACKGROUND: There is no acceptable maximum wall thickness (MWT) threshold for diagnosing apical hypertrophic cardiomyopathy (ApHCM), with guidelines referring to ≥15 mm MWT for all hypertrophic cardiomyopathy subtypes. A normal myocardium naturally tapers apically; a fixed diagnostic threshold fails to account for this. Using cardiac magnetic resonance, "relative" ApHCM has been described with typical electrocardiographic features, loss of apical tapering, and cavity obliteration but also with MWT <15 mm. OBJECTIVES: The authors aimed to define normal apical wall thickness thresholds in healthy subjects and use these to accurately identify ApHCM. METHODS: The following healthy subjects were recruited: healthy UK Biobank imaging substudy subjects (n = 4,112) and an independent healthy volunteer group (n = 489). A clinically defined disease population of 104 ApHCM subjects was enrolled, with 72 overt (MWT ≥15 mm) and 32 relative (MWT <15 mm but typical electrocardiographic/imaging findings) ApHCM subjects. Cardiac magnetic resonance-derived MWT was measured in 16 segments using a published clinically validated machine learning algorithm. Segmental normal reference ranges were created and indexed (for age, sex, and body surface area), and diagnostic performance was assessed. RESULTS: In healthy cohorts, there was no clinically significant age-related difference for apical wall thickness. There were sex-related differences, but these were not clinically significant after indexing to body surface area. Therefore, segmental reference ranges for apical hypertrophy required indexing to body surface area only (not age or sex). The upper limit of normal (the largest of the 4 apical segments measured) corresponded to a maximum apical MWT in healthy subjects of 5.2 to 5.6 mm/m2 with an accuracy of 0.94 (the unindexed equivalent being 11 mm). This threshold was categorized as abnormal in 99% (71/72) of overt ApHCM patients, 78% (25/32) of relative ApHCM patients, 3% (122/4,112) of UK Biobank subjects, and 3% (13/489) of healthy volunteers. CONCLUSIONS: Per-segment indexed apical wall thickness thresholds are highly accurate for detecting apical hypertrophy, providing confidence to the reader to diagnose ApHCM in those not reaching current internationally recognized criteria.

8.
Circulation ; 148(24): 1932-1944, 2023 12 12.
Article in English | MEDLINE | ID: mdl-37855144

ABSTRACT

BACKGROUND: The consequences of exercise-induced premature ventricular contractions (PVCs) in asymptomatic individuals remain unclear. This study aimed to assess the association between PVC burdens during submaximal exercise and major adverse cardiovascular events (MI/HF/LTVA: myocardial infarction [MI], heart failure [HF], and life-threatening ventricular arrhythmia [LTVA]), and all-cause mortality. Additional end points were MI, LTVA, HF, and cardiovascular mortality. METHODS: A neural network was developed to count PVCs from ECGs recorded during exercise (6 minutes) and recovery (1 minute) in 48 315 asymptomatic participants from UK Biobank. Associations were estimated using multivariable Cox proportional hazard models. Explorative studies were conducted in subgroups with cardiovascular magnetic resonance imaging data (n=6290) and NT-proBNP (N-terminal Pro-B-type natriuretic peptide) levels (n=4607) to examine whether PVC burden was associated with subclinical cardiomyopathy. RESULTS: Mean age was 56.8±8.2 years; 51.1% of the participants were female; and median follow-up was 12.6 years. Low PVC counts during exercise and recovery were both associated with MI/HF/LTVA risk, independently of clinical factors: adjusted hazard ratio (HR), 1.2 (1-5 exercise PVCs, P<0.001) and HR, 1.3 (1-5 recovery PVCs, P<0.001). Risks were higher with increasing PVC count: HR, 1.8 (>20 exercise PVCs, P<0.001) and HR, 1.6 (>5 recovery PVCs, P<0.001). A similar trend was observed for all-cause mortality, although associations were only significant for high PVC burdens: HRs, 1.6 (>20 exercise PVCs, P<0.001) and 1.5 (>5 recovery PVCs, P<0.001). Complex PVC rhythms were associated with higher risk compared with PVC count alone. PVCs were also associated with incident HF, LTVA, and cardiovascular mortality, but not MI. In the explorative studies, high PVC burden was associated with larger left ventricular volumes, lower ejection fraction, and higher levels of NT-proBNP compared with participants without PVCs. CONCLUSIONS: In this cohort of middle-aged and older adults, PVC count during submaximal exercise and recovery were both associated with MI/HF/LTVA, all-cause mortality, HF, LTVAs, and cardiovascular mortality, independent of clinical and exercise test factors, indicating an incremental increase in risk as PVC count rises. Complex PVC rhythms were associated with higher risk compared with PVC count alone. Underlying mechanisms may include the presence of subclinical cardiomyopathy.


Subject(s)
Cardiomyopathies , Heart Failure , Myocardial Infarction , Ventricular Premature Complexes , Middle Aged , Humans , Female , Aged , Male , Prognosis , Ventricular Premature Complexes/complications , Biological Specimen Banks , Heart Failure/complications , Cardiomyopathies/complications , Myocardial Infarction/complications
9.
Circulation ; 148(10): 808-818, 2023 09 05.
Article in English | MEDLINE | ID: mdl-37463608

ABSTRACT

BACKGROUND: In hypertrophic cardiomyopathy (HCM), myocyte disarray and microvascular disease (MVD) have been implicated in adverse events, and recent evidence suggests that these may occur early. As novel therapy provides promise for disease modification, detection of phenotype development is an emerging priority. To evaluate their utility as early and disease-specific biomarkers, we measured myocardial microstructure and MVD in 3 HCM groups-overt, either genotype-positive (G+LVH+) or genotype-negative (G-LVH+), and subclinical (G+LVH-) HCM-exploring relationships with electrical changes and genetic substrate. METHODS: This was a multicenter collaboration to study 206 subjects: 101 patients with overt HCM (51 G+LVH+ and 50 G-LVH+), 77 patients with G+LVH-, and 28 matched healthy volunteers. All underwent 12-lead ECG, quantitative perfusion cardiac magnetic resonance imaging (measuring myocardial blood flow, myocardial perfusion reserve, and perfusion defects), and cardiac diffusion tensor imaging measuring fractional anisotropy (lower values expected with more disarray), mean diffusivity (reflecting myocyte packing/interstitial expansion), and second eigenvector angle (measuring sheetlet orientation). RESULTS: Compared with healthy volunteers, patients with overt HCM had evidence of altered microstructure (lower fractional anisotropy, higher mean diffusivity, and higher second eigenvector angle; all P<0.001) and MVD (lower stress myocardial blood flow and myocardial perfusion reserve; both P<0.001). Patients with G-LVH+ were similar to those with G+LVH+ but had elevated second eigenvector angle (P<0.001 after adjustment for left ventricular hypertrophy and fibrosis). In overt disease, perfusion defects were found in all G+ but not all G- patients (100% [51/51] versus 82% [41/50]; P=0.001). Patients with G+LVH- compared with healthy volunteers similarly had altered microstructure, although to a lesser extent (all diffusion tensor imaging parameters; P<0.001), and MVD (reduced stress myocardial blood flow [P=0.015] with perfusion defects in 28% versus 0 healthy volunteers [P=0.002]). Disarray and MVD were independently associated with pathological electrocardiographic abnormalities in both overt and subclinical disease after adjustment for fibrosis and left ventricular hypertrophy (overt: fractional anisotropy: odds ratio for an abnormal ECG, 3.3, P=0.01; stress myocardial blood flow: odds ratio, 2.8, P=0.015; subclinical: fractional anisotropy odds ratio, 4.0, P=0.001; myocardial perfusion reserve odds ratio, 2.2, P=0.049). CONCLUSIONS: Microstructural alteration and MVD occur in overt HCM and are different in G+ and G- patients. Both also occur in the absence of hypertrophy in sarcomeric mutation carriers, in whom changes are associated with electrocardiographic abnormalities. Measurable changes in myocardial microstructure and microvascular function are early-phenotype biomarkers in the emerging era of disease-modifying therapy.


Subject(s)
Cardiomyopathy, Hypertrophic , Hypertrophy, Left Ventricular , Humans , Sarcomeres/genetics , Diffusion Tensor Imaging , Genetic Predisposition to Disease , Mutation , Cardiomyopathy, Hypertrophic/diagnosis , Phenotype , Biomarkers , Fibrosis
11.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-37001913

ABSTRACT

AIMS: The SMART Pass™ (SP) algorithm is a high-pass filter that aims to reduce inappropriate therapy (IT) in subcutaneous internal cardiac defibrillator (S-ICD), but SP can deactivate due to low amplitude sensed R waves or asystole. The association between IT and SP deactivation and management strategies were evaluated, hypothesizing SP deactivation increases the risk of IT and device re-programming, or lead/generator re-positioning could reduce this risk. METHODS AND RESULTS: Retrospective single-centre audit of Emblem™ S-ICD devices implanted 2016 to 2020 utilizing health records and remote monitoring data. Cox regression models evaluated associations between SP deactivation and IT. A total of 348 patients (27 ± 16.6 months follow-up) were studied: 73% primary prevention. Thirty-eight patients (11.8%) received 83 shocks with 27 patients (7.8%) receiving a total of 44 IT. Causes of IT were oversensing (98%) and aberrantly conducted atrial fibrillation (2%). SP deactivation occurred in 32 of 348 patients (9%) and was significantly associated with increased risk of IT (hazard ratio 5.36, 95% CI 2.37-12.13). SP deactivation was due to low amplitude R waves (94%), associated with a higher defibrillation threshold at implant and presence of arrhythmogenic right ventricular cardiomyopathy. No further IT occurred 16 ± 15.5 months after corrective interventions, with changing the sensing vector being successful in 59% of cases. CONCLUSION: To reduce the risk of IT, the cause of the SP deactivation should be investigated, and appropriate reprogramming, device, or lead modifications made. Utilizing the alert for SP deactivation and electrograms could pro-actively prevent IT.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Atrial Fibrillation , Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Retrospective Studies , Electric Countershock , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Atrial Fibrillation/etiology , Arrhythmogenic Right Ventricular Dysplasia/therapy
12.
Eur Heart J Digit Health ; 4(2): 112-118, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36974269

ABSTRACT

Aims: Wearable devices are transforming the electrocardiogram (ECG) into a ubiquitous medical test. This study assesses the association between premature ventricular and atrial contractions (PVCs and PACs) detected on wearable-format ECGs (15 s single lead) and cardiovascular outcomes in individuals without cardiovascular disease (CVD). Methods and results: Premature atrial contractions and PVCs were identified in 15 s single-lead ECGs from N = 54 016 UK Biobank participants (median age, interquartile range, age 58, 50-63 years, 54% female). Cox regression models adjusted for traditional risk factors were used to determine associations with atrial fibrillation (AF), heart failure (HF), myocardial infarction (MI), stroke, life-threatening ventricular arrhythmias (LTVAs), and mortality over a period of 11.5 (11.4-11.7) years. The strongest associations were found between PVCs (prevalence 2.2%) and HF (hazard ratio, HR, 95% confidence interval = 2.09, 1.58-2.78) and between PACs (prevalence 1.9%) and AF (HR = 2.52, 2.11-3.01), with shorter prematurity further increasing risk. Premature ventricular contractions and PACs were also associated with LTVA (P < 0.05). Associations with MI, stroke, and mortality were significant only in unadjusted models. In a separate UK Biobank sub-study sample [UKB-2, N = 29,324, age 64, 58-60 years, 54% female, follow-up 3.5 (2.6-4.8) years] used for independent validation, after adjusting for risk factors, PACs were associated with AF (HR = 1.80, 1.12-2.89) and PVCs with HF (HR = 2.32, 1.28-4.22). Conclusion: In middle-aged individuals without CVD, premature contractions identified in 15 s single-lead ECGs are strongly associated with an increased risk of AF and HF. These data warrant further investigation to assess the role of wearable ECGs for early cardiovascular risk stratification.

13.
Article in English | MEDLINE | ID: mdl-36833593

ABSTRACT

Arrhythmogenic right ventricular cardiomyopathy (ARVC) is an inherited cardiac disease associated with an increased risk of life-threatening arrhythmias. The aim of the present study was to evaluate the association of ventricular arrhythmias (VA) with circadian and seasonal variation in ARVC. One hundred two ARVC patients with an implantable cardioverter defibrillator (ICD) were enrolled in the study. Arrhythmic events included (a) any initial ventricular tachycardia (VT) or fibrillation (VF) prompting ICD implantation, (b) any VT or non-sustained VT (NSVT) recorded by the ICD, and (c) appropriate ICD shocks/therapy. Differences in the annual incidence of events across seasons (winter, spring, summer, autumn) and period of the day (night, morning, afternoon, evening) were assessed both for all cardiac events and major arrhythmic events. In total, 67 events prior to implantation and 263 ICD events were recorded. These included 135 major (58 ICD therapies, 57 self-terminating VT, 20 sustained VT) and 148 minor (NSVT) events. A significant increase in the frequency of events was observed in the afternoon versus in the nights and mornings (p = 0.016). The lowest number of events was registered in the summer, with a peak in the winter (p < 0.001). Results were also confirmed when excluding NSVT. Arrhythmic events in ARVC follow a seasonal variation and a circadian rhythm. They are more prevalent in the late afternoon, the most active period of the day, and in the winter, supporting the role of physical activity and inflammation as triggers of events.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Seasons , Arrhythmias, Cardiac , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/therapy , Arrhythmogenic Right Ventricular Dysplasia/complications , Arrhythmogenic Right Ventricular Dysplasia/therapy
14.
Europace ; 25(2): 536-545, 2023 02 16.
Article in English | MEDLINE | ID: mdl-36480445

ABSTRACT

AIMS: Cardiac resynchronization therapy programmed to dynamically fuse pacing with intrinsic conduction using atrioventricular (AV) timing algorithms (e.g. SyncAV) has shown promise; however, mechanistic data are lacking. This study assessed the impact of SyncAV on electrical dyssynchrony across various pacing modalities using non-invasive epicardial electrocardiographic imaging (ECGi). METHODS AND RESULTS: Twenty-five patients with left bundle-branch block (median QRS duration (QRSd) 162.7 ms) and intact AV conduction (PR interval 174.0 ms) were prospectively enrolled. ECGi was performed acutely during biventricular pacing with fixed nominal AV delays (BiV) and using SyncAV (optimized for the narrowest QRSd) during: BiV + SyncAV, LV-only single-site (LVSS + SyncAV), MultiPoint pacing (MPP + SyncAV), and LV-only MPP (LVMPP + SyncAV). Dyssynchrony was quantified via ECGi (LV activation time, LVAT; RV activation time, RVAT; LV electrical dispersion index, LVEDi; ventricular electrical uncoupling index, VEU; and biventricular total activation time, VVtat). Intrinsic conduction LVAT (124 ms) was significantly reduced by BiV pacing (109 ms) (P = 0.001) and further reduced by LVSS + SyncAV (103 ms), BiV + SyncAV (103 ms), LVMPP + SyncAV (95 ms), and MPP + SyncAV (90 ms). Intrinsic RVAT (93 ms), VVtat (130 ms), LVEDi (36 ms), VEU (50 ms), and QRSd (163 ms) were reduced by SyncAV across all pacing modes. More patients exhibited minimal LVAT, VVtat, LVEDi, and QRSd with MPP + SyncAV than any other modality. CONCLUSION: Dynamic AV delay programming targeting fusion with intrinsic conduction significantly reduced dyssynchrony, as quantified by ECGi and QRSd for all evaluated pacing modes. MPP + SyncAV achieved the greatest synchrony overall but not for all patients, highlighting the value of pacing mode individualization during fusion optimization.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Bundle-Branch Block/diagnostic imaging , Bundle-Branch Block/therapy , Heart Failure/therapy , Cardiac Resynchronization Therapy/methods , Electrocardiography , Cardiac Resynchronization Therapy Devices , Treatment Outcome
15.
J Am Heart Assoc ; 11(17): e025897, 2022 09 06.
Article in English | MEDLINE | ID: mdl-36036209

ABSTRACT

Background Early identification of individuals at risk of sudden cardiac death (SCD) remains a major challenge. The ECG is a simple, common test, with potential for large-scale application. We developed and tested the predictive value of a novel index quantifying T-wave morphologic variations with respect to a normal reference (TMV), which only requires one beat and a single-lead ECG. Methods and Results We obtained reference T-wave morphologies from 23 962 participants in the UK Biobank study. With Cox models, we determined the association between TMV and life-threatening ventricular arrhythmia in an independent data set from UK Biobank study without a history of cardiovascular events (N=51 794; median follow-up of 122 months) and SCD in patients with coronary artery disease from ARTEMIS (N=1872; median follow-up of 60 months). In UK Biobank study, 220 (0.4%) individuals developed life-threatening ventricular arrhythmias. TMV was significantly associated with life-threatening ventricular arrhythmias (hazard ratio [HR] of 1.13 per SD increase [95% CI, 1.03-1.24]; P=0.009). In ARTEMIS, 34 (1.8%) individuals reached the primary end point. Patients with TMV ≥5 had an HR for SCD of 2.86 (95% CI, 1.40-5.84; P=0.004) with respect to those with TMV <5, independently from QRS duration, corrected QT interval, and left ventricular ejection fraction. TMV was not significantly associated with death from a cause other than SCD. Conclusions TMV identifies individuals at life-threatening ventricular arrhythmia and SCD risk using a single-beat single-lead ECG, enabling inexpensive, quick, and safe risk assessment in large populations.


Subject(s)
Death, Sudden, Cardiac , Ventricular Function, Left , Arrhythmias, Cardiac , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Electrocardiography , Humans , Predictive Value of Tests , Prospective Studies , Risk Factors , Stroke Volume
16.
Circ Genom Precis Med ; 15(5): e003441, 2022 10.
Article in English | MEDLINE | ID: mdl-35861959

ABSTRACT

BACKGROUND: Coronary artery disease (CAD) and major adverse cardiovascular events (MACE) are the leading causes of death in the general population, but risk stratification remains suboptimal. CAD genetic risk scores (GRSs) predict risk independently from clinical tools, like QRISK3. We assessed the added value of GRSs for a variety of cardiovascular traits (CV GRSs) for predicting CAD and MACE and tested their early-life screening potential by comparing against the CAD GRS only. METHODS: We used data from 379 581 participants in the UK Biobank without known cardiovascular conditions (follow-up, 11.3 years; 3.3% CAD cases and 5.2% MACE cases). In a training subset (50%) we built 3 scores: QRISK3; QRISK3 and an established CAD GRS; and QRISK3, the CAD GRS and the CV GRSs. In an independent subset (50%), we evaluated each score's performance using the concordance index, odds ratio and net reclassification index. We then repeated the analyses without considering QRISK3. RESULTS: For CAD, the combination of QRISK3 and the CAD GRS had a better performance than QRISK3 alone (concordance index, 0.766 versus 0.753; odds ratio, 5.47 versus 4.82; net reclassification index, 7.7%). Adding the CV GRSs did not significantly improve risk stratification. When only looking at genetic information, the combination of CV GRSs and the CAD GRS had a better performance than the CAD GRS alone (concordance index, 0.637 versus 0.625; odds ratio, 2.17 versus 2.07; net reclassification index, 3.3%). Similar results were obtained for MACE. CONCLUSIONS: In individuals without known cardiovascular disease, the inclusion of CV GRSs to a clinical tool and an established CAD GRS does not improve CAD or MACE risk stratification. However, their combination only with the CAD GRS increases prediction performance indicating potential use in early-life screening before the advanced development of conventional cardiovascular risk factors.


Subject(s)
Cardiovascular Diseases , Coronary Artery Disease , Humans , Coronary Artery Disease/diagnosis , Coronary Artery Disease/genetics , Coronary Artery Disease/epidemiology , Risk Factors , Cardiovascular Diseases/genetics , Genetic Predisposition to Disease , Polymorphism, Single Nucleotide , Heart Disease Risk Factors
17.
JACC Clin Electrophysiol ; 8(4): 426-436, 2022 04.
Article in English | MEDLINE | ID: mdl-35450597

ABSTRACT

OBJECTIVES: This study sought to assess the association between electrocardiographic imaging (ECGI) parameters and voltage from simultaneous electroanatomic mapping (EAM). BACKGROUND: ECGI offers noninvasive assessment of electrophysiologic features relevant for mapping ventricular arrhythmia and its substrate, but the accuracy of ECGI in the delineation of scar is unclear. METHODS: Sixteen patients with structural heart disease underwent simultaneous ECGI (CardioInsight, Medtronic) and contact EAM (CARTO, Biosense-Webster) during ventricular tachycardia catheter ablation, with 7 mapped epicardially. ECGI and EAM geometries were coregistered using anatomic landmarks. ECGI points were paired to the closest site on the EAM within 10 mm. The association between EAM voltage and ECGI features from reconstructed epicardial unipolar electrograms was assessed by mixed-effects regression models. The classification of low-voltage regions was performed using receiver-operating characteristic analysis. RESULTS: A total of 9,541 ECGI points (median: 596; interquartile range: 377-737 across patients) were paired to an EAM site. Epicardial EAM voltage was associated with ECGI features of signal fractionation and local repolarization dispersion (N = 7; P < 0.05), but they poorly classified sites with bipolar voltage of <1.5 mV or <0.5 mV thresholds (median area under the curve across patients: 0.50-0.62). No association was found between bipolar EAM voltage and low-amplitude reconstructed epicardial unipolar electrograms or ECGI-derived bipolar electrograms. Similar results were found in the combined cohort (n = 16), including endocardial EAM voltage compared to epicardial ECGI features (n = 9). CONCLUSIONS: Despite a statistically significant association between ECGI features and EAM voltage, the accuracy of the delineation of low-voltage zones was modest. This may limit ECGI use for pr-procedural substrate analysis in ventricular tachycardia ablation, but it could provide value in risk assessment for ventricular arrhythmias.


Subject(s)
Heart Diseases , Tachycardia, Ventricular , Electrocardiography/methods , Endocardium , Epicardial Mapping/methods , Humans , Tachycardia, Ventricular/surgery
18.
BMC Cardiovasc Disord ; 22(1): 140, 2022 04 01.
Article in English | MEDLINE | ID: mdl-35365075

ABSTRACT

BACKGROUND: The life course accumulation of overt and subclinical myocardial dysfunction contributes to older age mortality, frailty, disability and loss of independence. The Medical Research Council National Survey of Health and Development (NSHD) is the world's longest running continued surveillance birth cohort providing a unique opportunity to understand life course determinants of myocardial dysfunction as part of MyoFit46-the cardiac sub-study of the NSHD. METHODS: We aim to recruit 550 NSHD participants of approximately 75 years+ to undertake high-density surface electrocardiographic imaging (ECGI) and stress perfusion cardiovascular magnetic resonance (CMR). Through comprehensive myocardial tissue characterization and 4-dimensional flow we hope to better understand the burden of clinical and subclinical cardiovascular disease. Supercomputers will be used to combine the multi-scale ECGI and CMR datasets per participant. Rarely available, prospectively collected whole-of-life data on exposures, traditional risk factors and multimorbidity will be studied to identify risk trajectories, critical change periods, mediators and cumulative impacts on the myocardium. DISCUSSION: By combining well curated, prospectively acquired longitudinal data of the NSHD with novel CMR-ECGI data and sharing these results and associated pipelines with the CMR community, MyoFit46 seeks to transform our understanding of how early, mid and later-life risk factor trajectories interact to determine the state of cardiovascular health in older age. TRIAL REGISTRATION: Prospectively registered on ClinicalTrials.gov with trial ID: 19/LO/1774 Multimorbidity Life-Course Approach to Myocardial Health- A Cardiac Sub-Study of the MCRC National Survey of Health and Development (NSHD).


Subject(s)
Cardiovascular Diseases , Magnetic Resonance Imaging , Aged , Cardiovascular Diseases/diagnostic imaging , Cardiovascular Diseases/epidemiology , Health Surveys , Heart , Humans , Myocardium
19.
JACC Clin Electrophysiol ; 8(2): 225-235, 2022 02.
Article in English | MEDLINE | ID: mdl-35210080

ABSTRACT

OBJECTIVES: The purpose of this study was to assess the performance and limitations of low-voltage zones (LVZ) localization by optimized late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) scar imaging in patients with cardiac implantable electronic devices (CIEDs). BACKGROUND: Scar evaluation by LGE-CMR can assist ventricular tachycardia (VT) ablation, but challenges with electroanatomical maps coregistration and presence of imaging artefacts from CIED limit accuracy. METHODS: A total of 10 patients underwent VT ablation and preprocedural LGE-CMR using wideband imaging. Scar was segmented from CMR pixel signal intensity maps using commercial software (ADAS-VT, Galgo Medical) with bespoke tools and compared with detailed electroanatomical maps (CARTO). Coregistration of EP and imaging-derived scar was performed using the aorta as a fiducial marker, and the impact of coregistration was determined by assessing intraobserver/interobserver variability and using computer simulations. Spatial smoothing was applied to assess correlation at different spatial resolutions and to reduce noise. RESULTS: Pixel signal intensity maps localized low-voltage zones (V <1.5 mV) with area under the receiver-operating characteristic curve: 0.82 (interquartile range [IQR]: 0.76-0.83), sensitivity 74% (IQR: 71%-77%), and specificity 78% (IQR: 73%-83%) and correlated with bipolar voltage (r = -0.57 [IQR: -0.68 to -0.42]) across patients. In simulations, small random shifts and rotations worsened LVZ localization in at least some cases. The use of the full aortic geometry ensured high reproducibility of LVZ localization (r >0.86 for area under the receiver-operating characteristic curve). Spatial smoothing improved localization of LVZ. Results for LVZ with V <0.5 mV were similar. CONCLUSIONS: In patients with CIEDs, novel wideband CMR sequences and personalized coregistration strategies can localize LVZ with good accuracy and may assist VT ablation procedures.


Subject(s)
Contrast Media , Tachycardia, Ventricular , Gadolinium , Humans , Magnetic Resonance Imaging/methods , Reproducibility of Results , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/pathology , Tachycardia, Ventricular/surgery
20.
Philos Trans A Math Phys Eng Sci ; 379(2212): 20200261, 2021 Dec 13.
Article in English | MEDLINE | ID: mdl-34689618

ABSTRACT

Stress test electrocardiogram (ECG) analysis is widely used for coronary artery disease (CAD) diagnosis despite its limited accuracy. Alterations in autonomic modulation of cardiac electrical activity have been reported in CAD patients during acute ischemia. We hypothesized that those alterations could be reflected in changes in ventricular repolarization dynamics during stress testing that could be measured through QT interval variability (QTV). However, QTV is largely dependent on RR interval variability (RRV), which might hinder intrinsic ventricular repolarization dynamics. In this study, we investigated whether different markers accounting for low-frequency (LF) oscillations of QTV unrelated to RRV during stress testing could be used to separate patients with and without CAD. Power spectral density of QTV unrelated to RRV was obtained based on time-frequency coherence estimation. Instantaneous LF power of QTV and QTV unrelated to RRV were obtained. LF power of QTV unrelated to RRV normalized by LF power of QTV was also studied. Stress test ECG of 100 patients were analysed. Patients referred to coronary angiography were classified into non-CAD or CAD group. LF oscillations in QTV did not show significant differences between CAD and non-CAD groups. However, LF oscillations in QTV unrelated to RRV were significantly higher in the CAD group as compared with the non-CAD group when measured during the first phases of exercise and last phases of recovery. ROC analysis of these indices revealed area under the curve values ranging from 61 to 73%. Binomial logistic regression analysis revealed LF power of QTV unrelated to RRV, both during the first phase of exercise and last phase of recovery, as independent predictors of CAD. In conclusion, this study highlights the importance of removing the influence of RRV when measuring QTV during stress testing for CAD identification and supports the added value of LF oscillations of QTV unrelated to RRV to diagnose CAD from the first minutes of exercise. This article is part of the theme issue 'Advanced computation in cardiovascular physiology: new challenges and opportunities'.


Subject(s)
Coronary Artery Disease , Coronary Artery Disease/diagnosis , Electrocardiography , Exercise Test , Heart Rate , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...