1.
Sensors (Basel) ; 24(11)2024 May 23.
Article in English | MEDLINE | ID: mdl-38894115

ABSTRACT

Recently, inertial measurement units have been gaining popularity as a potential alternative to optical motion capture systems in the analysis of joint kinematics. In a previous study, the accuracy of knee joint angles calculated from inertial data and an extended Kalman filter and smoother algorithm was tested using ground truth data originating from a joint simulator guided by fluoroscopy-based signals. Although high levels of accuracy were achieved, the experimental setup leveraged multiple iterations of the same movement pattern and an absence of soft tissue artefacts. Here, the algorithm is tested against an optical marker-based system in a more challenging setting, with single iterations of a loaded squat cycle simulated on seven cadaveric specimens on a force-controlled knee rig. Prior to the optimisation of local coordinate systems using the REference FRame Alignment MEthod (REFRAME) to account for the effect of differences in local reference frame orientation, root-mean-square errors between the kinematic signals of the inertial and optical systems were as high as 3.8° ± 3.5° for flexion/extension, 20.4° ± 10.0° for abduction/adduction and 8.6° ± 5.7° for external/internal rotation. After REFRAME implementation, however, average root-mean-square errors decreased to 0.9° ± 0.4° and to 1.5° ± 0.7° for abduction/adduction and for external/internal rotation, respectively, with a slight increase to 4.2° ± 3.6° for flexion/extension. While these results demonstrate promising potential in the approach's ability to estimate knee joint angles during a single loaded squat cycle, they highlight the limiting effects that a reduced number of iterations and the lack of a reliable consistent reference pose inflicts on the sensor fusion algorithm's performance. They similarly stress the importance of adapting underlying assumptions and correctly tuning filter parameters to ensure satisfactory performance. More importantly, our findings emphasise the notable impact that properly aligning reference-frame orientations before comparing joint kinematics can have on results and the conclusions derived from them.


Subject(s)
Algorithms , Knee Joint , Range of Motion, Articular , Humans , Biomechanical Phenomena/physiology , Knee Joint/physiology , Range of Motion, Articular/physiology , Cadaver , Movement/physiology , Male , Knee/physiology
2.
Sci Rep ; 13(1): 9632, 2023 06 14.
Article in English | MEDLINE | ID: mdl-37316703

ABSTRACT

In clinical movement biomechanics, kinematic data are often depicted as waveforms (i.e. signals), characterising the motion of articulating joints. Clinically meaningful interpretations of the underlying joint kinematics, however, require an objective understanding of whether two different kinematic signals actually represent two different underlying physical movement patterns of the joint or not. Previously, the accuracy of IMU-based knee joint angles was assessed using a six-degrees-of-freedom joint simulator guided by fluoroscopy-based signals. Despite implementation of sensor-to-segment corrections, observed errors were clearly indicative of cross-talk, and thus inconsistent reference frame orientations. Here, we address these limitations by exploring how minimisation of dedicated cost functions can harmonise differences in frame orientations, ultimately facilitating consistent interpretation of articulating joint kinematic signals. In this study, we present and investigate a frame orientation optimisation method (FOOM) that aligns reference frames and corrects for cross-talk errors, hence yielding a consistent interpretation of the underlying movement patterns. By executing optimised rotational sequences, thus producing angular corrections around each axis, we enable a reproducible frame definition and hence an approach for reliable comparison of kinematic data. Using this approach, root-mean-square errors between the previously collected (1) IMU-based data using functional joint axes, and (2) simulated fluoroscopy-based data relying on geometrical axes were almost entirely eliminated from an initial range of 0.7°-5.1° to a mere 0.1°-0.8°. Our results confirm that different local segment frames can yield different kinematic patterns, despite following the same rotation convention, and that appropriate alignment of reference frame orientation can successfully enable consistent kinematic interpretation.


Subject(s)
Knee Joint , Biomechanical Phenomena , Cross Reactions , Fluoroscopy , Rotation
3.
Sensors (Basel) ; 23(1)2022 Dec 29.
Article in English | MEDLINE | ID: mdl-36616945

ABSTRACT

The success of kinematic analysis that relies on inertial measurement units (IMUs) heavily depends on the performance of the underlying algorithms. Quantifying the level of uncertainty associated with the models and approximations implemented within these algorithms, without the complication of soft-tissue artefact, is therefore critical. To this end, this study aimed to assess the rotational errors associated with controlled movements. Here, data of six total knee arthroplasty patients from a previously published fluoroscopy study were used to simulate realistic kinematics of daily activities using IMUs mounted to a six-degrees-of-freedom joint simulator. A model-based method involving extended Kalman filtering to derive rotational kinematics from inertial measurements was tested and compared against the ground truth simulator values. The algorithm demonstrated excellent accuracy (root-mean-square error ≤0.9°, maximum absolute error ≤3.2°) in estimating three-dimensional rotational knee kinematics during level walking. Although maximum absolute errors linked to stair descent and sit-to-stand-to-sit rose to 5.2° and 10.8°, respectively, root-mean-square errors peaked at 1.9° and 7.5°. This study hereby describes an accurate framework for evaluating the suitability of the underlying kinematic models and assumptions of an IMU-based motion analysis system, facilitating the future validation of analogous tools.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Joint , Humans , Biomechanical Phenomena , Movement , Motion