Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
J Vasc Interv Radiol ; 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38901493

ABSTRACT

PURPOSE: To utilize a novel ex vivo perfused human renal model and quantify microwave ablation (MWA) size differences in renal tissue when combining MWA with transarterial embolization (TAE). MATERIALS AND METHODS: Human kidneys (n = 5) declined for transplantation were obtained and connected to a fluoroscopic-compatible ex vivo perfusion system. Two ablations-1 standard MWA, 1 TAE-MWA-were performed in each kidney for 2 minutes at 100 Watts using a MWA system (Solero Angiodynamics). MWA alone was performed in the upper pole. In the lower pole, MWA was performed after TAE with M0 LUMI microspheres (Boston Scientific) to achieve angiographic stasis. Ablation zones of coagulative necrosis were sectioned along the long axis and segmented for maximal short axis diameter (SAD) and long axis diameter (LAD) measurements. RESULTS: A total of 10 ablations (5 MWA, 5 TAE-MWA) were performed in five human kidneys. TAE-MWA resulted in significantly increased SAD, LAD, volume, and sphericity compared to standard MWA + SD with mean measurements as follows (5 standard MWA + SD vs 5 TAE-MWA, two-tailed t-test): SAD, 1.8 ± 0.1 cm vs 2.5 ± 0.1 cm (p < 0.001); LAD, 2.9 ± 0.3 cm vs 3.2 ± 0.1 cm (p = 0.039); volume, 5.0 ± 0.5 mL vs 11.0 ± 0.7 mL (p < 0.001); sphericity, 0.4 ± 0.2 vs 0.6 ± 0.1 (p = 0.049). Histology demonstrated no differences in TAE-MWA other than concentrated microspheres. CONCLUSION: This study utilized a novel ex vivo human kidney perfusion model to confirm combined MWA-TAE significantly increases ablation size and spherical shape.

2.
Radiographics ; 44(7): e230155, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38935550

ABSTRACT

Bile leaks arise from various causes such as trauma, complications after hepatobiliary surgery, and intrahepatic malignancies or their associated liver-directed treatments. Bile leaks can result in significant morbidity and mortality. Delayed diagnosis is not uncommon due to nonspecific manifestations; therefore, a high clinical suspicion is needed. A multidisciplinary approach for treatment of biliary leaks with prompt referral to tertiary care centers with experienced hepatobiliary surgeons, advanced endoscopists, and interventional radiologists is needed to address these challenging complications. Management of biliary leaks can range from conservative management to open surgical repair. Minimally invasive procedures play a crucial role in biliary leak treatment, and the interventional radiologist can help guide appropriate management on the basis of a clear understanding of the pathophysiology of biliary leaks and a current knowledge of the armamentarium of treatment options. In most cases, a simple diversion of bile to decompress the biliary system may prove effective. However, persistent and high-output biliary leaks require delineation of the source with tailored treatment options to control the leak. This may be done by additional diversions, occluding the source, reestablishing connections, or using a combination of therapies to bridge to more definitive surgical interventions. The authors describe the different treatment options and emphasize the role of interventional radiology. ©RSNA, 2024.


Subject(s)
Postoperative Complications , Humans , Postoperative Complications/diagnostic imaging , Postoperative Complications/therapy , Biliary Tract Diseases/diagnostic imaging , Biliary Tract Diseases/therapy , Anastomotic Leak/diagnostic imaging , Anastomotic Leak/therapy , Patient Care Team
3.
J Vasc Interv Radiol ; 35(1): 122-126, 2024 01.
Article in English | MEDLINE | ID: mdl-37696430

ABSTRACT

PURPOSE: To develop a reproducible in vitro model simulating central venous catheter (CVC) exchange with high potential for air embolization and test the hypothesis that a closed catheter clamp over hydrophilic guide wire exchange technique will significantly reduce the volume of air introduced during CVC exchange. MATERIALS AND METHODS: The model consisted of a 16-F valved sheath, 240-mL container, and pressure transducer submerged in water in a 1,200-mL suction canister system. Continuous wall suction was applied to the canister to maintain negative pressure at -7 mm Hg or -11 mm Hg. Each trial consisted of 0.035-inch hydrophilic guide wire introduction, over-the-wire catheter exchange, and wire removal following clinical protocol. A total of 256 trials were performed, 128 trials at each pressure with the catheter clamp open (n = 64) or closed (n = 64) around the hydrophilic guide wire. RESULTS: There was a statistically significant lower volume of air introduced with closed clamp over-the-wire exchanges than with open clamp exchanges at both pressures (2-tailed t-test, P < .001). At -7 mm Hg, a mean of 48.0 mL (SD ± 9.3) of air was introduced with open clamp and 20.6 mL (SD ± 4.7) of air was introduced with closed clamp. At -11 mm Hg, 97.8 mL (SD ± 11.9) of air was introduced with open clamp and 37.8 mL (SD ± 6.3) of air was introduced with closed clamp. CONCLUSIONS: This study demonstrated the use of a reproducible in vitro model mimicking conditions causing air embolism during CVC exchange. Results showed that CVC exchange using closed catheter clamp over hydrophilic guide wire exchange technique significantly reduced the volume of air introduced per exchange.


Subject(s)
Catheterization, Central Venous , Central Venous Catheters , Embolism, Air , Humans , Central Venous Catheters/adverse effects , Embolism, Air/etiology , Embolism, Air/prevention & control , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/methods
4.
J Vasc Interv Radiol ; 34(1): 40-45.e2, 2023 01.
Article in English | MEDLINE | ID: mdl-36244634

ABSTRACT

This study hypothesized that an ex vivo renal perfusion model can create smaller microwave ablation (MWA) measurements during perfused states compared with nonperfused states across multiple device settings. Nine bovine kidneys, a fluoroscopic compatible perfusion model, and a commercially-available clinical MWA system were used to perform 72 ablations (36 perfused and 36 nonperfused) at 9 different device settings. Comparing perfused and nonperfused ablations at each device setting, significant differences in volume existed for 6 of 9 settings (P < .05). Collapsed across time settings, the ablation volumes by power were the following (perfused and nonperfused, P value): 60 W, 2.3 cm3 ± 1.0 and 7.2 cm3 ± 2.7, P < .001; 100 W, 5.4 cm3 ± 2.1 and 11.5 cm3 ± 5.6, P < .01; and 140 W, 11.2 cm3 ± 3.7 and 18.7 cm3 ± 6.3, P < .01. Applied power correlated with ablation volume: perfused, 0.021 cm3/W and R = 0.462, P = .004, and nonperfused, 0.029 cm3/W and R = 0.565, P < .001. These results support that an ex vivo perfused organ system can evaluate MWA systems and demonstrate heat sink perfusion effects of decreased ablation size.


Subject(s)
Ablation Techniques , Catheter Ablation , Radiofrequency Ablation , Humans , Animals , Cattle , Liver/surgery , Microwaves/therapeutic use , Perfusion/methods , Catheter Ablation/methods , Kidney/surgery
5.
Am J Cardiol ; 181: 130-138, 2022 Oct 15.
Article in English | MEDLINE | ID: mdl-35999068

ABSTRACT

The aim of this secondary analysis of ELIMIT (The Effect of Lipid Modification on Peripheral Artery Disease after Endovascular Intervention Trial) was to determine longitudinal changes over 24 months in skeletal thigh muscle volumes and individual muscle compartments in patients with peripheral artery disease (PAD) with and without diabetes. A total of 48 patients with available magnetic resonance imaging of the distal superficial femoral artery at baseline and 2 years were included in this analysis. Muscle volumes and superficial femoral artery wall, lumen, and total vessel volumes were quantified. Intrareader reproducibility of muscle tracings was assessed with the intraclass correlation coefficient using a 2-way model. Baseline characteristics were similar between patients with PAD with and without diabetes, except for smoking history (p = 0.049), cholesterol levels (p <0.050), and calf walking pain (p = 0.049). Interobserver reproducibility of the muscle volume tracings was excellent for all muscle groups (all intraclass correlation coefficients >0.86, confidence interval 0.69 to 0.94). Total muscle and total leg volumes increased significantly between baseline and 24 months among patients with PAD without diabetes (31 ± 6.4 cm3 vs 32 ± 7.0 cm3, p <0.001; 18 ± 4.4 cm3 vs 19 ± 4.8 cm3, p = 0.045), whereas there was no change in patients with PAD and diabetes. Total muscle volume was inversely associated with age and body mass index in patients with PAD both with and without diabetes (p <0.05). In conclusion, magnetic resonance imaging-quantified thigh muscle volumes are highly reproducible and may be of interest in assessing PAD patients with and without diabetes.


Subject(s)
Diabetes Mellitus , Peripheral Arterial Disease , Humans , Magnetic Resonance Imaging , Muscle, Skeletal/blood supply , Muscle, Skeletal/diagnostic imaging , Peripheral Arterial Disease/diagnosis , Peripheral Arterial Disease/diagnostic imaging , Reproducibility of Results , Thigh/diagnostic imaging , Thigh/pathology
6.
Pediatr Radiol ; 49(1): 136-140, 2019 01.
Article in English | MEDLINE | ID: mdl-30167764

ABSTRACT

BACKGROUND: Spinal muscular atrophy (SMA) is an autosomal-recessive disease affecting motor neurons and is the most common genetic cause of death in infants. Intrathecal nusinersen is the only therapy approved by the U.S. Food and Drug Administration for SMA. Deformities and spinal instrumentation from orthopedic surgeries are common in children with SMA, complicating traditional intrathecal access for nusinersen delivery. Cervical punctures are routinely performed in adults for cervical myelograms and should be considered for children with SMA as a viable form of intrathecal access. OBJECTIVE: This retrospective study assessed technical feasibility and complications of ultrasound-guided cervical puncture for nusinersen administration. MATERIALS AND METHODS: We reviewed 14 consecutive ultrasound-guided cervical punctures for nusinersen administration with local anesthesia. We reviewed technical success and complications. RESULTS: All procedures were technically successful. There were no major complications. Two minor complications included headaches that resolved by observation within 24 h after the procedure. CONCLUSION: Our series describes a successful novel method of ultrasound-guided cervical spine access for intrathecal administration of nusinersen, adding to the armamentarium of procedures for delivering nusinersen to adolescents with challenging lumbar spine access caused by scoliosis and spinal instrumentation. This technique has the advantages of real-time ultrasound guidance and potential avoidance of general anesthesia in children.


Subject(s)
Muscular Atrophy, Spinal/drug therapy , Oligonucleotides/administration & dosage , Ultrasonography, Interventional , Adolescent , Child , Female , Humans , Male , Muscular Atrophy, Spinal/diagnostic imaging , Punctures , Retrospective Studies , Treatment Outcome , Young Adult
7.
Tex Med ; 98(12): 9, 2002 Dec.
Article in English | MEDLINE | ID: mdl-12515239
SELECTION OF CITATIONS
SEARCH DETAIL
...