Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Endourol ; 24(8): 1249-53, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20092414

ABSTRACT

INTRODUCTION AND OBJECTIVES: Cryoablation is a viable minimally invasive strategy for the treatment of small renal masses. One of the most common postoperative complaints is pain or paresthesia at the cryoprobe insertion site. The use of a 14-gauge angiocatheter to insulate the flank during renal cryotherapy was investigated. MATERIALS AND METHODS: Six Yorkshire swine underwent laparoscopy-guided percutaneous cryoablation of the upper and lower poles of both kidneys with a 1.47 mm (17 gauge) cryoneedle. Treatment consisted of a double 10-minute freeze separated by a 5-minute active thaw. Trials were randomized to placement of the cryoneedle directly through the flank or through a 14-gauge angiocatheter as an insulating sheath. Temperatures were recorded adjacent to the cryoneedle at two depths in the flank with a Multi-Point Thermal Sensor. RESULTS: Twelve trials were completed each with a bare and sheathed cryoneedle. The coldest temperature observed was -26 degrees C for the bare cryoneedle and -21 degrees C for the sheathed cryoneedle. At the outer sensor, there was a 4.1 degrees C increase in mean temperature for freeze 1, and 6.2 degrees C increase in mean temperature for freeze 2 with sheath use. At the inner sensor, there was a 3.0 degrees C increase in mean temperature for freeze 1, and 9.4 degrees C increase in mean temperature for freeze 2 with sheath use. There was a trend toward statistical significance of sheath insulation at the outer (p = 0.07) and inner (p = 0.08) temperature sensors. CONCLUSIONS: A 14-gauge angiocatheter may provide some insulation and thereby might help protect against "ice burn" during renal cryotherapy.


Subject(s)
Burns/etiology , Burns/prevention & control , Cryosurgery/adverse effects , Kidney/surgery , Animals , Body Temperature , Catheterization , Freezing , Ice , Laparoscopy , Swine
2.
J Endourol ; 24(3): 451-5, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20059350

ABSTRACT

INTRODUCTION: Laparoscopic partial nephrectomy (LPN) has not received widespread clinical application because of its technical challenge. Bovine serum albumin glutaraldehyde (BSAG) is a hemostatic agent that is independent of the clotting cascade. We evaluated the use of BSAG as the sole agent for parenchymal and collecting system closure during LPN in a survival porcine model. METHODS: Eighteen pigs underwent hilar clamping and LPN by longitudinal excision of the lateral one-third of the right kidney. The opened collecting system was covered with oxidized cellulose to prevent BSAG seepage into the urinary tract. BSAG was allowed to set for 10 or 5 minutes. Twelve animals underwent survival LPN BSAG only closure; six control pigs were acutely studied using saline. Urinary extravasation was evaluated by injection of furosemide and indigo carmine, and then evaluating the renal surface and bladder catheter drainage for dye. A subjective bleeding score was assigned after hilum unclamping. At 6 weeks, BSAG kidneys were harvested for burst pressure testing and histopathological analysis. RESULTS: All 12 pigs survived for 6 weeks. No pigs had urinary extravasation. Mean percentage of kidney removed by weight was 19%. Mean warm ischemia time was 29 minutes. Five pigs required a second BSAG application to achieve a bleeding score of 0. Mean arterial and collecting system burst pressures were 301.8 and 322.4 mm Hg, respectively. Mean postoperative creatinine increase was 0.07 mg/dL. CONCLUSION: BSAG for completely sutureless LPN in a survival porcine model was feasible.


Subject(s)
Glutaral/therapeutic use , Laparoscopy , Models, Animal , Nephrectomy/methods , Serum Albumin, Bovine/therapeutic use , Sus scrofa/surgery , Sutures , Animals , Glutaral/chemistry , Serum Albumin, Bovine/chemistry , Survival Analysis