1.
Int J Mol Sci ; 24(10)2023 May 15.
Article in English | MEDLINE | ID: mdl-37240108

ABSTRACT

Previously, functional coatings on 3D-printed titanium implants were developed to improve their biointegration by separately incorporating Ga and Ag on the biomaterial surface. Now, a thermochemical treatment modification is proposed to study the effect of their simultaneous incorporation. Different concentrations of AgNO3 and Ga(NO3)3 are evaluated, and the obtained surfaces are completely characterized. Ion release, cytotoxicity, and bioactivity studies complement the characterization. The provided antibacterial effect of the surfaces is analyzed, and cell response is assessed by the study of SaOS-2 cell adhesion, proliferation, and differentiation. The Ti surface doping is confirmed by the formation of Ga-containing Ca titanates and nanoparticles of metallic Ag within the titanate coating. The surfaces generated with all combinations of AgNO3 and Ga(NO3)3 concentrations show bioactivity. The bacterial assay confirms a strong bactericidal impact achieved by the effect of both Ga and Ag present on the surface, especially for Pseudomonas aeruginosa, one of the main pathogens involved in orthopedic implant failures. SaOS-2 cells adhere and proliferate on the Ga/Ag-doped Ti surfaces, and the presence of gallium favors cell differentiation. The dual effect of both metallic agents doping the titanium surface provides bioactivity while protecting the biomaterial from the most frequent pathogens in implantology.


Subject(s)
Gallium , Titanium , Titanium/pharmacology , Titanium/chemistry , Silver/pharmacology , Silver/chemistry , Osseointegration , Porosity , Gallium/pharmacology , Coated Materials, Biocompatible/pharmacology , Coated Materials, Biocompatible/chemistry , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Surface Properties
2.
Front Bioeng Biotechnol ; 10: 838415, 2022.
Article in English | MEDLINE | ID: mdl-35356783

ABSTRACT

Critical-sized defects of irregular bones requiring bone grafting, such as in craniofacial reconstruction, are particularly challenging to repair. With bone-grafting procedures growing in number annually, there is a reciprocal growing interest in bone graft substitutes to meet the demand. Autogenous osteo(myo)cutaneous grafts harvested from a secondary surgical site are the gold standard for reconstruction but are associated with donor-site morbidity and are in limited supply. We developed a bone graft strategy for irregular bone-involved reconstruction that is customizable to defect geometry and patient anatomy, is free of synthetic materials, is cellularized, and has an outer pre-vascularized tissue layer to enhance engraftment and promote osteogenesis. The graft, comprised of bioprinted human-derived demineralized bone matrix blended with native matrix proteins containing human mesenchymal stromal cells and encased in a simple tissue shell containing isolated, human adipose microvessels, ossifies when implanted in rats. Ossification follows robust vascularization within and around the graft, including the formation of a vascular leash, and develops mechanical strength. These results demonstrate an early feasibility animal study of a biofabrication strategy to manufacture a 3D printed patient-matched, osteoconductive, tissue-banked, bone graft without synthetic materials for use in craniofacial reconstruction. The bone fabrication workflow is designed to be performed within the hospital near the Point of Care.

3.
Int J Mol Sci ; 23(3)2022 Feb 03.
Article in English | MEDLINE | ID: mdl-35163682

ABSTRACT

A lack of primary stability and osteointegration in metallic implants may result in implant loosening and failure. Adding porosity to metallic implants reduces the stress shielding effect and improves implant performance, allowing the surrounding bone tissue to grow into the scaffold. However, a bioactive surface is needed to stimulate implant osteointegration and improve mechanical stability. In this study, porous titanium implants were produced via powder sintering to create different porous diameters and open interconnectivity. Two strategies were used to generate a bioactive surface on the metallic foams: (1) an inorganic alkali thermochemical treatment, (2) grafting a cell adhesive tripeptide (RGD). RGD peptides exhibit an affinity for integrins expressed by osteoblasts, and have been reported to improve osteoblast adhesion, whereas the thermochemical treatment is known to improve titanium implant osseointegration upon implantation. Bioactivated scaffolds and control samples were implanted into the tibiae of rabbits to analyze the effect of these two strategies in vivo regarding bone tissue regeneration through interconnected porosity. Histomorphometric evaluation was performed at 4 and 12 weeks after implantation. Bone-to-implant contact (BIC) and bone in-growth and on-growth were evaluated in different regions of interest (ROIs) inside and outside the implant. The results of this study show that after a long-term postoperative period, the RGD-coated samples presented higher quantification values of quantified newly formed bone tissue in the implant's outer area. However, the total analyzed bone in-growth was observed to be slightly greater in the scaffolds treated with alkali thermochemical treatment. These results suggest that both strategies contribute to enhancing porous metallic implant stability and osteointegration, and a combination of both strategies might be worth pursuing.


Subject(s)
Alkalies/pharmacology , Coated Materials, Biocompatible/pharmacology , Metallurgy , Oligopeptides/pharmacology , Osseointegration , Temperature , Tissue Scaffolds/chemistry , Titanium/pharmacology , Animals , Female , Implants, Experimental , Osseointegration/drug effects , Osteogenesis/drug effects , Porosity , Powders , Rabbits
4.
J Prosthet Dent ; 127(3): 470-476, 2022 Mar.
Article in English | MEDLINE | ID: mdl-33309211

ABSTRACT

STATEMENT OF PROBLEM: Polyetheretherketone (PEEK) has been advocated to replace metal components in dentistry. Although PEEK is a high-performance polymer with a white color, adequate biological response, and resistance to fracture, data to support PEEK as an alternative material for implant abutments are lacking. PURPOSE: The purpose of this in vitro study was to assess the mechanical and functional properties of PEEK implant abutments as a nonmetallic alternative to titanium abutments, which presents esthetic limitations and greater difficulty to customize clinically. MATERIAL AND METHODS: Implant abutments manufactured by using PEEK (n=24) or titanium grade 5 (n=24) were attached to MIS Implants type M4 3.75×16 mm with an internal screw tightened to 25 Ncm. Screw loosening and microleakage was assessed by submersion in a 2% methylene blue solution for 48 hours at 37 °C. Both groups were compared with and without applying dynamic loading; fatigue testing was performed following the International Organization for Standardization (ISO) 14801:2016 standard. All specimens were observed under a stereomicroscope at ×8 magnification. Statistically significant differences among the PEEK and titanium implant abutments were tested with 2-factor ANOVA and the chi-square analysis for nonpaired and paired data, respectively (α=.05). RESULTS: The implant abutments made of titanium were better in all mechanical tests. The torque loss of titanium abutments was approximately 10%, while PEEK showed a significantly higher (P<.05) torque loss of up to 50%. Moreover, 91.6% of the titanium abutments did not present microleakage, while there was no specimen of PEEK abutments without microleakage, once subjected to dynamic loading (P<.05). CONCLUSIONS: Titanium implant abutments (Ti6Al4V) were better in all tests performed. However, PEEK abutments may be suitable for long-term interim restorations, especially in the anterior area, in patients without parafunction.


Subject(s)
Dental Implants , Titanium , Benzophenones , Bone Screws , Dental Abutments , Dental Implant-Abutment Design , Dental Restoration Failure , Dental Stress Analysis , Esthetics, Dental , Humans , Materials Testing , Mechanical Tests , Polymers , Zirconium
5.
J Occup Environ Hyg ; 18(6): 265-275, 2021 06.
Article in English | MEDLINE | ID: mdl-33989113

ABSTRACT

The COVID-19 pandemic has caused a high demand for respiratory protection among health care workers in hospitals, especially surgical N95 filtering facepiece respirators (FFRs). To aid in alleviating that demand, a survey of commercially available filter media was conducted to determine whether any could serve as a substitute for an N95 FFR while held in a 3D-printed mask (Stopgap Surgical Face Mask from the NIH 3D Print Exchange). Fourteen filter media types and eight combinations were evaluated for filtration efficiency, breathing resistance (pressure drop), and liquid penetration. Additional testing was conducted to evaluate two filter media disinfection methods in the event that the filters were reused in a hospital setting. Efficiency testing was conducted in accordance with the procedures established for approving an N95 FFR. One apparatus used a filter-holding device and another apparatus employed a manikin head to which the 3D-printed mask could be sealed. The filter media and combinations exhibited collection efficiencies varied between 3.9% and 98.8% when tested with a face velocity comparable to that of a standard N95 FFR at the 85 L min-1 used in the approval procedure. Breathing resistance varied between 10.8 to >637 Pa (1.1 to > 65 mm H2O). When applied to the 3D-printed mask efficiency decreased by an average of 13% and breathing resistance increased 4-fold as a result of the smaller surface area of the filter media when held in that mask compared to that of an N95 FFR. Disinfection by dry heat, even after 25 cycles, did not significantly affect filter efficiency and reduced viral infectivity by > 99.9%. However, 10 cycles of 59% vaporized H2O2 significantly (p < 0.001) reduced filter efficiency of the media tested. Several commercially available filter media were found to be potential replacements for the media used to construct the typical cup-like N95 FFR. However, their use in the 3D-printed mask demonstrated reduced efficiency and increased breathing resistance at 85 L min-1.


Subject(s)
COVID-19/prevention & control , Disinfection/standards , Equipment Contamination/prevention & control , Materials Testing/standards , N95 Respirators/virology , Occupational Exposure/prevention & control , Pandemics/prevention & control , Air Pollutants, Occupational/analysis , Equipment Failure Analysis/statistics & numerical data , Guidelines as Topic , Humans , Inhalation Exposure/analysis , SARS-CoV-2
6.
Infect Control Hosp Epidemiol ; 42(3): 253-260, 2021 03.
Article in English | MEDLINE | ID: mdl-32783787

ABSTRACT

BACKGROUND: Personal protective equipment (PPE) is a critical need during the coronavirus disease 2019 (COVID-19) pandemic. Alternative sources of surgical masks, including 3-dimensionally (3D) printed approaches that may be reused, are urgently needed to prevent PPE shortages. Few data exist identifying decontamination strategies to inactivate viral pathogens and retain 3D-printing material integrity. OBJECTIVE: To test viral disinfection methods on 3D-printing materials. METHODS: The viricidal activity of common disinfectants (10% bleach, quaternary ammonium sanitizer, 3% hydrogen peroxide, or 70% isopropanol and exposure to heat (50°C, and 70°C) were tested on four 3D-printed materials used in the healthcare setting, including a surgical mask design developed by the Veterans' Health Administration. Inactivation was assessed for several clinically relevant RNA and DNA pathogenic viruses, including severe acute respiratory coronavirus virus 2 (SARS-CoV-2) and human immunodeficiency virus 1 (HIV-1). RESULTS: SARS-CoV-2 and all viruses tested were completely inactivated by a single application of bleach, ammonium quaternary compounds, or hydrogen peroxide. Similarly, exposure to dry heat (70°C) for 30 minutes completely inactivated all viruses tested. In contrast, 70% isopropanol reduced viral titers significantly less well following a single application. Inactivation did not interfere with material integrity of the 3D-printed materials. CONCLUSIONS: Several standard decontamination approaches effectively disinfected 3D-printed materials. These approaches were effective in the inactivation SARS-CoV-2, its surrogates, and other clinically relevant viral pathogens. The decontamination of 3D-printed surgical mask materials may be useful during crisis situations in which surgical mask supplies are limited.


Subject(s)
COVID-19/prevention & control , Disinfectants/pharmacology , Disinfection/methods , Masks , SARS-CoV-2/drug effects , Virus Inactivation , 2-Propanol , DNA, Viral/drug effects , Decontamination/methods , HIV-1/drug effects , Healthy Volunteers , Hot Temperature , Humans , Hydrogen Peroxide , Personal Protective Equipment , Printing, Three-Dimensional , RNA, Viral/drug effects , Virus Diseases/prevention & control
7.
Materials (Basel) ; 13(23)2020 Nov 24.
Article in English | MEDLINE | ID: mdl-33255355

ABSTRACT

Although ceramic-on-ceramic (CoC) bearings have been shown to produce the smallest amount of wear volume in vitro as well as in vivo studies when used for total hip arthroplasties (THA), concerns about the failure of these bearing surfaces persist due to early failures observed after short postoperative time. In this study, an exhaustive analysis of the early failure occurred on the new generation of ceramic bearings, consisting of a composite alumina matrix-based material reinforced with yttria-stabilized tetragonal zirconia (Y-TZP) particles, chromium dioxide, and strontium crystals, was performed. For this study, 118 CoC bearings from 117 patients were revised. This article describes a group of mechanical failure CoC-bearing BIOLOX THA hip prosthesis patients without trauma history. The retrieved samples were observed under scanning electron microscopy (SEM), composition was analyzed with energy dispersive X-ray spectroscopy (EDX), and damaged surfaces were analyzed by grazing-incidence X-ray diffraction (GI-XRD) and white light interferometry. In the short term, CoC articulations provided similar mechanical behavior and functional outcome to those in XLPE cases. However, 5% more early mechanical failures cases were observed for the ceramic components. Although the fracture rate of third generation CoC couples is low, the present study shows the need to further improve the third generation of CoC-bearing couples for THA. Despite the improved wear compared to other materials, stress concentrators are sources of initial crack propagation, such as those found in the bore-trunnion areas. Moreover, in view of the evidence observed in this study, the chipping observed was due to the presence of monoclinic phase of the Y-TZP instead of tetragonal, which presents better mechanical properties. The results showed that total safety after receiving a THA is still a goal to be pursued.

8.
Tissue Eng Part A ; 26(17-18): 993-1004, 2020 09.
Article in English | MEDLINE | ID: mdl-32122263

ABSTRACT

Osteonecrosis of the femoral head (ONFH) is defined as a tissue disorder and successive subchondral bone collapse resulting from an ischemic process, which may progress to hip osteoarthritis. Cell therapy with multipotent bone marrow mesenchymal stromal cells (BM-MSC) of autologous origin appears to be safe and has shown regenerative potential in previous preclinical and clinical studies. The use of allogeneic cells is far more challenging, but may be a promising alternative to use of autologous cells. Moreover, an optimized dosage of cells from an allogeneic source is needed to obtain off-the-shelf tissue engineering products (TEPs). The purpose of this study was to evaluate the efficacy of a TEP composed of undifferentiated ex vivo expanded BM-MSC of allogeneic origin, combined with bone matrix particles in variable doses. A comparative analysis of TEP's bone regenerative properties against its autologous counterpart was performed in an early-stage ONFH preclinical model in mature sheep. Allogeneic BM-MSC groups demonstrated bone regeneration capacity in osteonecrotic lesions equivalent to autologous BM-MSC groups 6 weeks after treatment. Likewise, stimulation of bone regeneration by a low cell dose of 0.5 × 106 BM-MSC/cm3 was equivalent to that of a high cell dose, 5 × 106 BM-MSC/cm3. Neither local nor systemic immunological reactions nor tumorigenesis were reported, strengthening the safety profile of allogeneic BM-MSC therapy in this model. Our results suggest that low-dose allogeneic BM-MSC is sufficient to promote bone regeneration in femoral head osteonecrotic lesions, and should be considered in translation of new allogeneic cell-based TEPs to human clinics. Impact statement Cell therapy and tissue engineering hold promise as novel regenerative therapies for musculoskeletal diseases, and particularly in bone regeneration strategies. In this article, we report the evaluation of the efficacy of an allogeneic cell-based tissue engineering product (TEP) in an early-stage osteonecrosis of the femoral head preclinical model in skeletally mature sheep. Moreover, we demonstrate its bone regeneration capacity and safety in vivo and its equivalence to autologous counterparts. These findings have important implications for the translation of new allogeneic cell-based TEPs to human clinics.


Subject(s)
Mesenchymal Stem Cell Transplantation , Osteonecrosis , Tissue Engineering , Allogeneic Cells , Animals , Mesenchymal Stem Cells , Osteonecrosis/therapy , Sheep
9.
Materials (Basel) ; 12(19)2019 Sep 27.
Article in English | MEDLINE | ID: mdl-31569702

ABSTRACT

OBJECTIVES: The aim of this research was to determine the osseointegration of two presentations of biphasic calcium phosphate (BCP) biomaterial-one untreated and another submitted to biofunctionalization with a TGF-ß1 inhibitor peptide, P144, on dental alveolus. Materials and Methods: A synthetic bone graft was used, namely, (i) Maxresorb® (Botiss Klockner) (n = 12), and (ii) Maxresorb® (Botiss Klockner) biofunctionalized with P144 peptide (n = 12). Both bone grafts were implanted in the two hemimandibles of six beagle dogs in the same surgical time, immediately after tooth extraction. Two dogs were sacrificed 2, 4, and 8 weeks post implant insertion, respectively. The samples were submitted to histomorphometrical and histological analyses. For each sample, we quantified the new bone growth and the new bone formed around the biomaterial's granules. After optical microscopic histological evaluation, selected samples were studied using backscattered scanning electron microscopy (BS-SEM). Results: The biofunctionalization of the biomaterial's granules maintains a stable membranous bone formation throughout the experiment timeline, benefitting from the constant presence of vascular structures in the alveolar space, in a more active manner that in the control samples. Better results in the experimental groups were proven both by quantitative and qualitative analysis. Conclusions: Synthetic bone graft biofunctionalization results in slightly better quantitative parameters of the implant's osseointegration. The qualitative histological and ultramicroscopic analysis shows that biofunctionalization may shorten the healing period of dental biomaterials.

10.
Int J Mol Sci ; 19(9)2018 Aug 30.
Article in English | MEDLINE | ID: mdl-30200178

ABSTRACT

In this study, highly-interconnected porous titanium implants were produced by powder sintering with different porous diameters and open interconnectivity. The actual foams were produced using high cost technologies: Chemical Vapor Deposition (CVD), Physical Vapor Deposition (PVD), and spark plasma sintering, and the porosity and/or interconnection was not optimized. The aim was to generate a bioactive surface on foams using two different strategies, based on inorganic thermo-chemical treatment and organic coating by peptide adsorption, to enhance osseointegration. Porosity was produced using NaCl as a space holder and polyethyleneglicol as a binder phase. Static and fatigue tests were performed in order to determine mechanical behaviors. Surface bioactivation was performed using a thermo-chemical treatment or by chemical adsorption with peptides. Osteoblast-like cells were cultured and cytotoxicity was measured. Bioactivated scaffolds and a control were implanted in the tibiae of rabbits. Histomorphometric evaluation was performed at 4 weeks after implantation. Interconnected porosity was 53% with an average diameter of 210 µm and an elastic modulus of around 1 GPa with good mechanical properties. The samples presented cell survival values close to 100% of viability. Newly formed bone was observed inside macropores, through interconnected porosity, and on the implant surface. Successful bone colonization of inner structure (40%) suggested good osteoconductive capability of the implant. Bioactivated foams showed better results than non-treated ones, suggesting both bioactivation strategies induce osteointegration capability.


Subject(s)
Coated Materials, Biocompatible/chemistry , Osseointegration/drug effects , Osteoblasts/cytology , Tibia/surgery , Titanium/chemistry , Adsorption , Animals , Cell Survival , Cells, Cultured , Female , Porosity , Prostheses and Implants , Rabbits , Stress, Mechanical , Surface Properties , Temperature
11.
J Mater Sci Mater Med ; 27(10): 151, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27582071

ABSTRACT

Intervertebral implants should be designed with low load requirements, high friction coefficient and low elastic modulus in order to avoid the stress shielding effect on bone. Furthermore, the presence of a highly interconnected porous structure allows stimulating bone in-growth and enhancing implant-bone fixation. The aim of this study was to obtain bioactive porous titanium implants with highly interconnected pores with a total porosity of approximately 57 %. Porous Titanium implants were produced by powder sintering route using the space holder technique with a binder phase and were then evaluated in an in vivo study. The size of the interconnection diameter between the macropores was about 210 µm in order to guarantee bone in-growth through osteblastic cell penetration. Surface roughness and mechanical properties were analyzed. Stiffness was reduced as a result of the powder sintering technique which allowed the formation of a porous network. Compression and fatigue tests exhibited suitable properties in order to guarantee a proper compromise between mechanical properties and pore interconnectivity. Bioactivity treatment effect in novel sintered porous titanium materials was studied by thermo-chemical treatments and were compared with the same material that had undergone different bioactive treatments. Bioactive thermo-chemical treatment was confirmed by the presence of sodium titanates on the surface of the implants as well as inside the porous network. Raman spectroscopy results suggested that the identified titanate structures would enhance in vivo apatite formation by promoting ion exchange for the apatite formation process. In vivo results demonstrated that the bioactive titanium achieved over 75 % tissue colonization compared to the 40 % value for the untreated titanium.


Subject(s)
Osteoblasts/metabolism , Oxides/chemistry , Titanium/chemistry , Animals , Biocompatible Materials/chemistry , Compressive Strength , Elastic Modulus , Female , Friction , Materials Testing , Microscopy, Electron, Scanning , Porosity , Powders , Prostheses and Implants , Prosthesis Design , Rabbits , Spectrum Analysis, Raman , Stress, Mechanical , Surface Properties , Temperature
12.
Mater Sci Eng C Mater Biol Appl ; 38: 55-62, 2014 May 01.
Article in English | MEDLINE | ID: mdl-24656352

ABSTRACT

Achieving high quality 3D-printed structures requires establishing the right printing conditions. Finding processing conditions that satisfy both the fabrication process and the final required scaffold properties is crucial. This work stresses the importance of studying the outcome of the plasticizing effect of PEG on PLA-based blends used for the fabrication of 3D-direct-printed scaffolds for tissue engineering applications. For this, PLA/PEG blends with 5, 10 and 20% (w/w) of PEG and PLA/PEG/bioactive CaP glass composites were processed in the form of 3D rapid prototyping scaffolds. Surface analysis and differential scanning calorimetry revealed a rearrangement of polymer chains and a topography, wettability and elastic modulus increase of the studied surfaces as PEG was incorporated. Moreover, addition of 10 and 20% PEG led to non-uniform 3D structures with lower mechanical properties. In vitro degradation studies showed that the inclusion of PEG significantly accelerated the degradation rate of the material. Results indicated that the presence of PEG not only improves PLA processing but also leads to relevant surface, geometrical and structural changes including modulation of the degradation rate of PLA-based 3D printed scaffolds.


Subject(s)
Lactic Acid/chemistry , Polyethylene Glycols/chemistry , Polymers/chemistry , Tissue Engineering/methods , Tissue Scaffolds/chemistry , Interferometry , Mechanical Phenomena , Microscopy, Atomic Force , Microscopy, Electron, Scanning , Polyesters , Porosity , Temperature