Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 55
Filter
1.
Arch Orthop Trauma Surg ; 144(5): 1997-2006, 2024 May.
Article in English | MEDLINE | ID: mdl-38570357

ABSTRACT

BACKGROUND: This study aimed to meta-analyze epidemiological data, revision rates, and incidences of different designs of a single Total Knee Arthroplasty System and compare these factors across different countries. METHODS: A systematic review was conducted on clinical studies and arthroplasty registries of ATTUNE TKA from 1999 to 2020. The main endpoints analyzed were revision rates and epidemiological data. RESULTS: The average age of patients was 67.8 years, with a gender distribution of 60% female and 40% male. The pooled average BMI was 29.4 kg/m2. Eight clinical studies showed a pooled revision rate per 100 observed CY of 0.5 (n = 1343 cases). Cumulative revision rates after 1, 3, and 5 years varied among registries, with the Swiss registry having the highest revision data (after 5 years: 6.3%) and the American registry having the lowest revision data (after 5 years: 1.7%). A comparison of the revision rates of mobile bearing and fixed bearing (41,200 cases) as well as cruciate retaining and posterior stabilized (n = 123,361 cases) showed no significant advantage in the first 5 years after implantation. CONCLUSION: In conclusion, pooled data from 41,200 cases of TKA with a single Total Knee Arthroplasty System in two arthroplasty registries revealed that there was no significant difference in revision rates between the mobile bearing and fixed bearing design within the first 5 years after implantation. In addition, a comparison of the revision rates in n = 123,361 cases showed no significant advantage for cruciate retaining or posterior stabilized in the first 5 years after implantation.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Prosthesis Design , Registries , Reoperation , Humans , Arthroplasty, Replacement, Knee/statistics & numerical data , Arthroplasty, Replacement, Knee/methods , Reoperation/statistics & numerical data , Male , Female , Prosthesis Failure , Clinical Trials as Topic/statistics & numerical data , Aged
2.
Orthop J Sports Med ; 12(4): 23259671241237798, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38576874

ABSTRACT

Background: The long head of the biceps tendon (LHBT) is a well-known source of pain in the shoulder, especially in active patients. Purpose: To evaluate the outcomes and return-to-sports rate after all-arthroscopic suprapectoral tenodesis of the LHBT using a small knotless anchor. Study Design: Case series; Level of evidence, 4. Methods: In this retrospective study, 27 patients-who underwent all-arthroscopic tenodesis of the LHBT using a 2.7-mm knotless polyether ether ketone anchor-were evaluated. Sports activities, the return-to-sports rate, and other sports-related parameters (eg, pain during sports, level of sports) were examined. Sports-related data, the Constant score with isometric force (at 90° of abduction in the scapular plane), the American Shoulder and Elbow Surgeons (ASES) score, the Simple Shoulder Test (SST) score, the visual analog scale (VAS) score for satisfaction, range of motion, and the presence of a Popeye deformity were assessed at a mean follow-up of 15.3 ± 8.7 months. The data were initially analyzed using descriptive statistics. Results: The postoperative ASES, Constant, and SST scores were 81.61, 85.74 and 8.85, respectively. Of the 27 patients, 4 patients (14.8%) showed a Popeye deformity. Preoperatively, 25 patients (92.6%) participated regularly in some type of sports activity. All 25 patients (100.0%) were able to return to sports activities after surgery. 24 (96.0%) returned to the same level preoperatively, with 88.0% (22/25) within 6 months. Patient satisfaction with the outcome was high (VAS score: 2.15 ± 2.78). Neither bicipital groove pain nor cramping was reported. There were no signs of osteolytic bone around the anchor or a fracture of the humeral bone. Conclusion: Our clinical results after using a 2.7-mm knotless anchor for LHBT tenodesis as well as the return-to-sports rate were satisfying. Using an anchor this size can lower the risk of cortical bone damage and therefore the risk of fractures of the humeral head while still enabling patients to perform at a high level.

3.
J Clin Med ; 13(7)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38610787

ABSTRACT

Background: Reversed total shoulder arthroplasty (RTSA) is an established surgery for many pathologies of the shoulder and the demand continues to rise with an aging population. Preoperative planning is mandatory to support the surgeon's understanding of the patient's individual anatomy and, therefore, is crucial for the patient's outcome. Methods: In this observational study, we identified 30 patients who underwent RTSA with two- and three-dimensional preoperative planning. Each patient underwent new two-dimensional planning from a medical student and an orthopedic resident as well as through a mid-volume and high-volume shoulder surgeon, which was repeated after a minimum of 4 weeks. The intra- and interobserver reliability was then analyzed and compared to the 3D planning and the implanted prosthesis. The evaluated parameters were the size of the pegged glenoid baseplate, glenosphere, and humeral short stem. Results: The inter-rater reliability showed higher deviations in all four raters compared to the 3D planning of the base plate, glenosphere, and shaft. The intra-rater reliability showed a better correlation in more experienced raters, especially in the planning of the shaft. Conclusions: Our study shows that 3D planning is more accurate than traditional planning on plain X-rays, despite experienced shoulder surgeons showing better results in 2D planning than inexperienced ones.

4.
Int Orthop ; 48(1): 229-234, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37606768

ABSTRACT

PURPOSE: Calcar-guided short-stem total hip arthroplasty (THA) has shown excellent clinical outcomes. However, the migration pattern of such prostheses and its effect on clinical outcomes are less known. Therefore, we assessed the five-year subsidence after calcar-guided short-stem THA and its implications on clinical outcomes, patient-related factors, and complications. METHODS: In this prospective multicentre study, we enrolled 213 patients (224 hips) who underwent calcar-guided short-stem THA mostly for degenerative hip diseases. We examined patients radiographically and clinically after six to 12 weeks, one year, two years, and five years. We evaluated subsidence using Einzel-Bild-Roentgen-Analyse femoral component analysis, assessed clinical outcomes, and systematically recorded all complications. RESULTS: Overall, 131 patients (133 hips) were available for final follow-up at a median of 60 months (range, 2 to 72 months). We found a mean subsidence of 0.63 ± 1.22 mm at three months, 1.03 ± 1.60 mm at one year, 1.21 ± 1.91 mm at two years, and 1.54 ± 1.97 mm at five years. Patient-related factors (sex, age, weight, and BMI) did not significantly impact subsidence at five years (P > 0.05). Additionally, the Harris hip score, pain, and satisfaction improved significantly at five years compared to pre-operative values (P < 0.0001). Lastly, five patients underwent revision. CONCLUSION: Calcar-guided short-stems revealed the highest subsidence rate within the first three months after THA and stabilisation after one year through the final follow-up examination. Moreover, patient-related factors had no influence on subsidence. Finally, clinical scores and patient satisfaction remained high at five years.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Child, Preschool , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis/adverse effects , Prospective Studies , Treatment Outcome , Prosthesis Design , Follow-Up Studies , Retrospective Studies
5.
Arch Orthop Trauma Surg ; 144(3): 1401-1414, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37924371

ABSTRACT

INTRODUCTION: Short stems are a valuable option in young patients undergoing total hip arthroplasty (THA) because of their bone stock preserving properties facilitating revision hip arthroplasty. Although the effect of obesity on conventional THA is well studied, data about short stem THA in obese patients are lacking. Therefore, this study aimed to investigate the influence of obesity on complications, revisions, and outcome after short stem THA. MATERIALS AND METHODS: This multicenter, observational cohort study included patients undergoing short stem THA with the optimys prosthesis. Follow-up examinations were performed at specific intervals up to 7 years postoperatively. Operation characteristics, general and specific complications, revisions, VAS rest pain, VAS load pain, VAS patient satisfaction, and Harris Hip Score (HHS) were recorded and statistically compared between obese (BMI ≥ 30 kg/m2) and non-obese (BMI < 30 kg/m2) patients. RESULTS: Of the 224 patients included with a mean follow-up of 87.2 months (range 81.9-104.0), 69 were assigned to the OB group and 155 to the non-OB group. A minimally invasive approach was significantly less often selected in obese patients (p = 0.049), whereas operating time and length of hospital stay were not significantly different. The rate of general and specific complications did not significantly differ between both groups. Survival of the optimys prosthesis was 99.1% at 7-year follow-up and one patient per group had to undergo revision surgery. VAS rest pain, load pain, and satisfaction improved from preoperatively to postoperatively in both groups without a significant difference between both groups. While the HHS was improved from preoperatively to postoperatively, obese patients showed a significantly lower HHS at the 7-year follow-up (p = 0.01) but still exhibited an excellent scoring above the PASS threshold. CONCLUSION: Short stem THA with the optimys prosthesis is a safe and effective option also in obese patients with an excellent clinical outcome and a low complication rate.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Arthroplasty, Replacement, Hip/adverse effects , Follow-Up Studies , Prosthesis Design , Obesity/complications , Obesity/surgery , Pain/etiology , Treatment Outcome , Retrospective Studies
6.
J Clin Med ; 12(20)2023 Oct 21.
Article in English | MEDLINE | ID: mdl-37892800

ABSTRACT

BACKGROUND: Total hip arthroplasty (THA) affects the biomechanics of the hip and the patient gait. The stem design influences femoral lever ratios and tissue trauma. Biomechanical changes such as these have the potential to induce knee arthritis. A varus or valgus configuration of knee arthritis is formed by asymmetric loadings. The aim of this study was to evaluate the impact of stem design in THA on knee valgus by comparing a standard implant with an implant with a short stem. METHODS: A total of 2953 patients who underwent primary total knee arthroplasty for end-stage osteoarthritis between 2015 and 2021 were included in this retrospective data analysis. Patients were divided into three groups, depending on hip status (straight stem, short stem, and native joint). Leg alignment was distinguished as varus or valgus, and the degree of axial deviation was measured. Descriptive and explorative statistical analyses were performed, with a p value < 0.05 set as significant. RESULTS: Ipsilateral knee valgus occurred significantly more often in patients with straight stems (57.2%) than in those with short stems (29%) and native joints (25.8%) (p < 0.001). Additionally, mean valgus deviation was significantly increased in patients with straight stems (8.9°) compared to those with short stems (6.4°) or native hip joints (6.7°). Both findings were accentuated in women. CONCLUSIONS: Previous ipsilateral straight-stem THA is associated with knee valgus deformity, especially in women. Short-stem THA seems to be better suited to restoring physiological biomechanics and preventing the development of valgus osteoarthritis of the ipsilateral knee.

7.
J Orthop ; 43: 93-100, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37575949

ABSTRACT

Background: Metaphyseal fixation of short stem THA allows for minimally invasive surgery, less bone removal, improved bone load transfer and reduced stress shielding. Short stems facilitate the anatomic restoration i.a. of leg length, femoroacetabular offset, and center of rotation. However, metaphyseal fixation might cause impaired primary and/or secondary stability resulting in an inherent tendency for early axial migration and aseptic loosening eventually. The objective of this study was to investigate the long-term outcome and migration pattern of a calcar-guided short stem. Methods: In a prospective multicenter study, 213 patients (224 THAs) were enrolled. Patients were followed for up to 84 months postoperatively. Clinical outcome was assessed using the Harris Hip Score and the VAS for pain and satisfaction. Standardized and calibrated radiographs were screened i.a. for stress shielding and loosening. Einzel-Bild-Roentgen-Analyse - femoral component analysis (EBRA-FCA) was used to detect longitudinal subsidence. Results: At 7 year follow-up, n = 139/224 cases were available for analysis. All clinical parameters improved significantly (p < 0.001) and improvement persisted. There were no radiographic changes indicating stress shielding. EBRA-FCA revealed a mean subsidence of -1.44 mm followed by a stabilization. Weight >80 kg (p = 0.115), BMI <30 kg/m2 (p = 0.282), male gender (p = 0.246), and age <65 years (p = 0.304) seemed to be associated with a higher risk for migration. The cumulative revision rate was 2.23%. Revisions due to stem migration (0.89%) occurred early (mean time between index surgery and revision: 3.3 months). Conclusions: If at all, there appears to be a pronounced initial subsidence, which stabilizes thereafter. Stem migration was rarely a compelling reason for failure or revision. Demographics do not seem to have a significant effect on migration pattern. The absence of radioluce lines, resorption or hypertrophy of the proximal femora support the hypothesis of a reduced stress shielding for metaphyseal anchoring short stems.

8.
World J Clin Cases ; 11(18): 4412-4418, 2023 Jun 26.
Article in English | MEDLINE | ID: mdl-37449214

ABSTRACT

BACKGROUND: Pancreatitis, panniculitis, and polyarthritis (PPP) syndrome is a rare form of pancreatic disease. It is characterized by bullous erythematous skin lesions and arthritis, and both are triggered by pancreatic malfunction. Few cases have been described in the literature thus far. Due to the inconsistency in its clinical presentation, its diagnosis can be a challenge. Early therapy initiation is essential to reduce mortality; however, there is currently no gold standard for treatment. CASE SUMMARY: A 66-year-old polymorbid male patient presented with several superficial abscesses on both lower legs and painful swelling in the knee. Treatment for septic arthritis and septic skin infection over several weeks failed. His general condition deteriorated gradually and worsened with sudden onset of abdominal pain. A diagnosis of necrotizing pancreatitis was made. He subsequently underwent a laparotomy and drainage of the pancreas. Eventually, our patient improved, and his abdominal complaints, knee pain, and dermal lesions resolved. CONCLUSION: PPP syndrome is rare and easily misdiagnosed, as abdominal symptoms may be delayed or absent. Clinicians should consider PPP syndrome if they encounter refractory panniculitis in combination with joint infection.

9.
Medicina (Kaunas) ; 59(5)2023 Apr 24.
Article in English | MEDLINE | ID: mdl-37241064

ABSTRACT

Background and Objectives: Short-stem total hip arthroplasty has become increasingly popular in recent years. While many studies have shown excellent clinical and radiological results, very little is known about the learning curve for short-stem total hip arthroplasty through an anterolateral approach. Therefore, the aim of this study was to determine the learning curve for short-stem total hip arthroplasty among five residents in training. Materials and Methods: We performed retrospective data analysis of the first 30 cases of five randomly selected residents (n = 150 cases) with no experience before the index surgery. All patients were comparable, and several surgical parameters and radiological outcomes were analyzed. Results: The only surgical parameter with a significant improvement was the surgical time (p = 0.025). The changes in other surgical parameters and radiological outcomes showed no significant changes; only trends can be derived. As a result, the correlation between surgical time, blood loss, length of stay, and incision/suture time can also be seen. Only two of the five residents showed significant improvements in all examined surgical parameters. Conclusions: There are individual differences among the first 30 cases of the five residents. Some improved their surgical skills faster than others. It could be assumed that they assimilated their surgical skills after more surgeries. A further study with more than 30 cases of the five surgeons could provide more information on that assumption.


Subject(s)
Arthroplasty, Replacement, Hip , Humans , Retrospective Studies , Learning Curve , Radiography , Operative Time , Treatment Outcome
10.
World J Clin Cases ; 11(3): 677-683, 2023 Jan 26.
Article in English | MEDLINE | ID: mdl-36793627

ABSTRACT

BACKGROUND: Brucellosis is the most common zoonosis worldwide and is endemic in the Middle East, Africa, Asia, and Latin America. However, it is uncommon in Central Europe, and periprosthetic infections caused by Brucella are therefore rare. Due to the low prevalence and nonspecific clinical presentation of the disease, accurate diagnosis can be challenging; no gold standard currently exists for treating brucellosis. CASE SUMMARY: Here, we present a 68-year-old Afghan woman living in Austria with a periprosthetic knee infection caused by Brucella melitensis. The interval from total knee arthroplasty to septic loosening was five years. A profound medical history and examinations suggested that the patient had been suffering from unrecognized chronic osteoarticular brucellosis prior to total knee arthroplasty. She was successfully treated by two-stage revision surgery and combined antibiotic therapy over three months. CONCLUSION: Clinicians should consider brucellosis as a possible cause of chronic arthralgia and periprosthetic infection in patients originating from countries with a high brucellosis burden.

11.
Eur Spine J ; 32(3): 867-873, 2023 03.
Article in English | MEDLINE | ID: mdl-36633691

ABSTRACT

PURPOSE: Posterior instrumentation is the state-of-the-art surgical treatment for fractures of the thoracic and lumbar spine. Options for pedicle screw placement comprise open or minimally invasive techniques. Open instrumentation causes large approach related muscle detachment, which minimally invasive techniques aim to reduce. However, concerns of accurate pedicle screw placement are still a matter of debate. Beside neurological complications due to pedicle screw malplacement, also affection of the facet joints and thus motion dependent pain is known as a complication. The aim of this study was to assess accuracy of pedicle screw placement concerning facet joint violation (FJV) after open- and minimally invasive posterior instrumentation. METHODS: A retrospective data analysis of postoperative computer tomographic scans of 219 patients (1124 pedicle screws) was conducted. A total of 116 patients underwent open screw insertion (634 screws) and 103 patients underwent minimally invasive, percutaneous screw insertion (490 screws). RESULTS: In the lumbar spine (segments L3, L4, L5), there were significantly more and higher grade (open = 0.55 vs. percutaneous = 1.2; p = 0.001) FJV's after percutaneously compared to openly inserted screws. In the thoracic spine, no significant difference concerning rate and grade of FJV was found (p > 0.56). CONCLUSION: FJV is more likely to occur in percutaneously placed pedicle screws. Additionally, higher grade FJV's occur after percutaneous instrumentation. However, in the thoracic spine we didn't find a significant difference between open and percutaneous technique. Our results suggest a precise consideration concerning surgical technique according to the fractured vertebrae in the light of the individual anatomic structures in the preop CT.


Subject(s)
Pedicle Screws , Spinal Fractures , Spinal Fusion , Zygapophyseal Joint , Humans , Zygapophyseal Joint/diagnostic imaging , Zygapophyseal Joint/surgery , Retrospective Studies , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Spinal Fractures/diagnostic imaging , Spinal Fractures/surgery , Pedicle Screws/adverse effects , Spinal Fusion/adverse effects
12.
J Funct Morphol Kinesiol ; 8(1)2023 Jan 11.
Article in English | MEDLINE | ID: mdl-36648900

ABSTRACT

Rotator cuff tear arthropathy (CTA) is the most common reason for reverse total shoulder arthroplasty (RSA). There is minimal understanding of the natural progression of osteoarthritis of the shoulder and of the morphologic differences between men and women and between younger and older patients. This trial comprised 309 patients (342 shoulders) who underwent RSA due to CTA in the period between January 2009 and September 2019. The patients were divided into gender and age groups. Preoperative X-rays, computed tomography and magnetic resonance imaging were conducted using various classifications to describe the morphology of the CTA. Of all 342 analyzed shoulders, 209 were right and 133 were left shoulders. A total of 257 female shoulders and 85 male shoulders were assessed. Both mean age and age distribution were significantly different (74.37 years in female and 70.11 years in male patients, p = 0.001; 70.2% female patients in the age group <75.5 years and 80.1% in the age group >75.5 years, p = 0.045). A larger extent of progression of the fatty infiltration was detected both in the female cohort (p = 0.006) and in the older age group (p = 0.001). Additionally, older patients had significantly higher levels of muscle retraction (Patte; p = 0.003), a lower acromiohumeral distance (p = 0.042) and more advanced CTA (Seebauer; p = 0.006).

13.
Eur Spine J ; 32(1): 368-373, 2023 01.
Article in English | MEDLINE | ID: mdl-36416969

ABSTRACT

PURPOSE: Measurement of neck rotation is currently reliant on radiologic imaging. Given the radiation exposure for CT imaging and the additional inconvenience for the patients, an alternative assessment is needed. Goniometers are comfortably to use and easy to access, also for private consulting. The aim of this study was the assessment of whether a handheld goniometer can be used for accurately measuring the rotation of C1-C2. METHODS: Clinical measurement of rotation was taken in flexed position of the neck. As comparison functional MRI was used. The measured rotation of C1-C2 was compared to identify the accuracy of the goniometer, in comparison to functional MRI scan. RESULTS: Analysis of accuracy using a goniometer and dynamic MRI to assess C1-2 axial rotation showed significant differences for absolute values, but not regarding the percentage of rotation compared to total neck rotation. CONCLUSION: The goniometer is exact to impartially determine the percentage contribution of C1-2 rotation to total neck rotation.


Subject(s)
Atlanto-Axial Joint , Cervical Vertebrae , Humans , Cervical Vertebrae/diagnostic imaging , Rotation , Atlanto-Axial Joint/diagnostic imaging , Magnetic Resonance Imaging , Range of Motion, Articular , Biomechanical Phenomena
14.
Sports (Basel) ; 10(12)2022 Dec 15.
Article in English | MEDLINE | ID: mdl-36548507

ABSTRACT

BACKGROUND: Data on the effects of weight training on joint morphology are mostly restricted to muscle gain. However, in many circumstances, it is not stated if there are negative consequences for the joints and their surrounding components. This study was conducted to explore whether long-term excessive resistance training (RT) causes hidden pathological alterations in the shoulder. METHODS: A total of eleven asymptomatic sportsmen (22 shoulders) underwent clinical and radiological examination of both shoulder joints. All participants had engaged in bodybuilding for at least four years, at least three times per week, and for at least four hours per week. All participants were examined clinically using the Constant Murley Score (CMS), Simple Shoulder Test (SST), UCLA Activity Test, and a specially designed questionnaire. All participants received a bilateral shoulder MRI. The MRI scans were checked for pathology using a checklist. RESULTS: Maximum scores were observed for the SST and UCLA Activity Test. The CMS was 97.7 points on average (range, 87-100). RT had been conducted for a mean of 10.7 years (range, 4-20), for an average of 8.8 h a week (range, 4-12). MRI examinations revealed two supraspinatus tendinopathies (9.1%), one labral change (4.5%), three humeral tuberosity cysts (13.6%), fourteen acromioclavicular (AC) joint hypertrophies (63.6%), five AC joint osteophytes (22.7%), and ten signs of AC joint inflammation (45.5%). CONCLUSIONS: The research results show that strength is associated with MRI-documented AC joint pathology. However, it appears that RT may not negatively affect other anatomical structures of the shoulder.

15.
J Clin Med ; 11(24)2022 Dec 07.
Article in English | MEDLINE | ID: mdl-36555886

ABSTRACT

Reverse total shoulder arthroplasty presents itself sometimes as challenging when it comes to addressing massive bone loss, either in primary or revision settings. Custom components recently have made their way into shoulder prosthetics and are meant to help in the case of extensive glenoid bone destruction. Because of strict indication and the fairly recent introduction of these implants, the usage of custom-made glenoid implants is not very common yet. However, the early results are promising. The purpose of this review was to summarize and analyze the available literature. Therefore, a systematic review was performed according to PRISMA guidelines. A comprehensive search of the databases PubMed, Cochrane, and Livivo was performed to screen for studies reporting on clinical and radiological outcomes of custom glenoid implants. Four studies with a total of 46 shoulders were included in this review. The mean patient age was 68.8 years and the mean time of follow-up was 24.3 months. The weighted means showed an increase in CMS (32.7 points), in ASES (39.8 points), in anteversion (67.4 degrees), and in abduction (51.9 degrees) and a decrease in VAS (5.4 points). Custom-made glenoid implants are therefore a viable option in cases of large combined glenoid bone loss, both in primary and revision shoulder arthroplasty.

16.
J Clin Med ; 11(20)2022 Oct 17.
Article in English | MEDLINE | ID: mdl-36294428

ABSTRACT

Background: Glenoid wear is a common complication of anatomical total shoulder arthroplasty (aTSA) with a metal-backed glenoid (MBG), and the clinical and radiological results of historical implants are poor. The aim of this work was to evaluate the clinical and radiological results of 25 participants as well as the longevity after implantation of an anatomic shoulder prosthesis with a recent, modular cementless flat metal-backed glenoid component after a mean follow-up of 5.7 years. Methods: Clinically, the Simple Shoulder Test (SST), UCLA Activity Score (UCLA), and Constant Murley Score (CMS) were evaluated. Radiographically, the radiolucent lines (RLs), humeral head migration (HHM), and lateral glenohumeral offset (LGHO) were assessed. Survival was calculated with Kaplan−Meier curves and life-table analysis. Results: The mean CMS at follow-up was 46.2 points (range: 14−77; SD: 19.5). In terms of the SST score, the average value was 6.5 points (range: 1−10; SD: 3.5). The UCLA activity score showed a mean value of 5.9 points (range: 1−9; SD: 2.1). There were 17 revisions after a mean follow-up of 68.2 months (range: 1.8−119.6; SD: 27.9). HHM occurred in every patient, with a mean measurement of 6.4 mm (range: 0.5−13.4; SD: 3.9; p < 0.0001). The mean LGHO between the initial postoperative and follow-up images was 2.6 mm (range: 0−4.0; SD: 1.5; p < 0.0001). RLs were found in 22 patients (88%) around the glenoid and in 21 patients (84%) around the humeral head prosthesis. Conclusion: The clinical and radiographic outcomes after metal-backed glenoids were poor at 2.2 to 8.4 years of follow-up. We determined devastating survival in the majority of cases (68%), with mostly inlay wear (71%) as the main reason that led to revision surgery. The use of metalback genoids cannot be recommended based on the data of this study.

17.
J Clin Med ; 11(11)2022 May 31.
Article in English | MEDLINE | ID: mdl-35683515

ABSTRACT

BACKGROUND: Acromial Levy III fractures after inverse shoulder arthroplasty occur in up to 7% of patients. To date, it is not clear how these fractures should be treated as clinical outcomes remain unsatisfactory. The aim of this study was to evaluate the biomechanical performance of three different plating methods of type III acromion fractures. METHODS: Levy III fractures in synthetic scapulae were fixed with three different methods. Angular stable locking plates were placed on the spina scapula to bridge the fracture either dorsally, caudally, or on both aspects by double plating. In a biomechanical experiment, the pull of the deltoid muscle at 40° abduction of the arm was simulated by cyclic loading with increasing load levels until failure. Failure load, cycles to failure, and fragment motions were evaluated. RESULTS: The results showed that double plating (350 ± 63 N) withstood the highest loads until failure, followed by dorsal (292 ± 20 N) and caudal (217 ± 49 N) plating. Similarly, double plating showed significantly smaller fragment movement than the other two groups. CONCLUSIONS: Double plating appeared to provide the largest biomechanical stability in type III acromion fracture under arm abduction. Caudal plating in contract resulted in insufficient fracture stability and early failure and can thus not be recommended from a biomechanical point of view.

18.
J Clin Med ; 11(3)2022 Jan 22.
Article in English | MEDLINE | ID: mdl-35160000

ABSTRACT

Glenoid implant position and fixation are challenging in severe glenoid defects in reverse total shoulder arthroplasty (rTSA). Custom-made glenoid implants are metal augmented implants that are specially produced for a certain defect. They provide the restoration of the joint line and proper fixation. This retrospective data analysis investigated the clinical and radiological outcomes after revision using custom-made glenoid implants. Between 2018 and 2020, nine patients (10 shoulders) with severe glenoid defects underwent revision rTSA using a custom-made glenoid implant (Materialise Glenius or Lima ProMade). The pre- and postoperative Constant Murley Score (CMS), UCLA Score and Subjective Shoulder Value (SSV) were assessed. Postoperative CT scans and X-rays in two planes were available. The minimum follow-up was 12 months, with a mean follow-up of 23.1 months. The mean preoperative CMS, UCLA Score and SSV were 10.9, 4.1 and 11.0, respectively. The mean postoperative CMS, UCLA Score and SSV showed significant increases of 51.7 (<0.001), 22.9 (<0.001) and 52.0 (<0.001), respectively. There were no signs of loosening implants or scapular notching, and no revision was necessary. This trial showed promising clinical and radiological short-term outcomes for custom-made glenoid components in revision rTSA.

19.
Am J Sports Med ; 50(2): 471-477, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35060768

ABSTRACT

BACKGROUND: Predicting the risk of recurrence is of great interest when counseling patients after primary lateral patellar dislocation (LPD). PURPOSE: To investigate a multivariate model to predict the individual risk of recurrent LPD. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: The study population included patients with primary LPD, knee imaging, and a minimum 2-year follow-up after nonoperative treatment. Data including patient characteristics and anatomic patellar instability risk factors were collected retrospectively from 7 national study centers. Bivariate and multivariate regression analyses were carried out to identify risk factors for recurrent LPD and to generate an accuracy-optimized model for out-of-sample prediction. RESULTS: In total, 115 of 201 patients (57%) experienced recurrent LPD within 2 years after primary LPD. Age ≤16 years at primary LPD (odds ratio [OR], 5.0), history of contralateral instability (OR, 2.4), and trochlear dysplasia (Dejour type B-D: OR, 2.5; lateral trochlear inclination ≤12°: OR, 2.7) were significant risk factors for recurrent LPD (P < .05). The prediction accuracy including these 3 risk factors was 79%. Patella alta, an increased tibial tubercle to trochlear groove distance, and patellar tilt had neither an association with increased recurrence rates nor an influence on prediction accuracy of recurrent LPD. CONCLUSION: Young age and trochlear dysplasia are major risk factors for early recurrent LPD. A multivariate model including age at primary LPD, lateral trochlear inclination, and history of contralateral LPD achieved the highest prediction accuracy. Based on these findings, the patellar instability probability calculator is proposed to estimate the individual risk of early recurrence when counseling patients after primary LPD.


Subject(s)
Joint Instability , Patellar Dislocation , Patellofemoral Joint , Adolescent , Case-Control Studies , Humans , Joint Instability/surgery , Odds Ratio , Patella/surgery , Patellar Dislocation/epidemiology , Patellofemoral Joint/surgery , Recurrence , Retrospective Studies
20.
Oper Orthop Traumatol ; 34(1): 21-33, 2022 Feb.
Article in German | MEDLINE | ID: mdl-35037092

ABSTRACT

OBJECTIVES: Reconstruction of the superior capsule for treatment of irreparable supraspinatus tendon tears. INDICATIONS: Irreparable supraspinatus tendon tear; centered humeral head; largely intact cartilage; largely intact transversal "force-couple". CONTRAINDICATIONS: Decentered humeral head; osteoarthritis of the glenohumeral joint/cuff tear arthropathy; irreparable anterosuperior and posterosuperior cuff tears. SURGICAL TECHNIQUE: Arthroscopic superior capsule reconstruction (SCR) is performed in beach-chair position. At first the bone bed of the glenoid and the insertion of the supraspinatus tendon are prepared using a bone burr. Now, depending on the integrity of the long biceps tendon, two options are possible. Option 1: In the case of an existing long biceps tendon, a biceps tendon tenodesis to the greater tubercle is performed. Therefore, the long head of the biceps is fixed central to the former insertion of the supraspinatus tendon, using a suture anchor. Option 2: In the case of a nonexisting or degeneratively modified long biceps tendon, a PushLock® anchor (Arthrex, Inc. Naples, FL, USA) loaded with a FiberTape® (Arthrex, Inc. Naples, FL, USA) is placed centrally onto the glenoid. Now, the actual superior capsule reconstruction is completed. Two suture anchors are placed at the glenoid and two SwiveLock® anchors, each loaded with a FiberTape®, (Arthrex, Inc. Naples, FL, USA) are placed at the footprint of the supraspinatus tendon at the greater tubercle. The tapes are shuttled extra-articularly and the graft size is evaluated by measuring the distance between the anchors. The graft is customized to that size and armed with the tapes. Using the tapes of the glenoidal anchors, as tension ropes, the graft is placed intra-articularly. Medially the sutures are tied and laterally the graft is fixed in a knotless lateral row manner. The tails of the tape, of the glenoidal PushLock® (Arthrex, Inc. Naples, FL, USA) anchor are fixed within the lateral row and are tensioned above the graft. Afterwards side-to-side sutures to the infraspinatus and a subacromial decompression are completed. POSTOPERATIVE MANAGEMENT: The arm is placed in a sling for 6 weeks, afterwards active physiotherapy begins. Passive-assisted physiotherapy is started on postoperative day 1. RESULTS: Between 2017 and 2019, 11 patients were treated with SCR. As the combined procedure is our new treatment algorithm, case studies will be presented. For this study, 9 patients treated with singular SCR, with a mean follow-up of 18 months, were recruited. A statistically significant reduction of pain (VAS 6.3 → VAS 2), a good postoperative forward flexion (mean 138°; 56 standard deviation [SD]), and external rotation (mean 37°; 21 SD) were measured. A mean ASES of 76.5 (18 SD) a mean DASH of 17.8 (14 SD) and a mean Constant score of 64.6 (25 SD) were achieved.


Subject(s)
Rotator Cuff Injuries , Shoulder Joint , Humans , Rotator Cuff , Rotator Cuff Injuries/surgery , Shoulder Joint/diagnostic imaging , Shoulder Joint/surgery , Tendons , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...