Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
World J Gastrointest Surg ; 13(8): 772-787, 2021 Aug 27.
Article in English | MEDLINE | ID: mdl-34512901

ABSTRACT

Endoscopic submucosal dissection (ESD) is a globally accepted minimally invasive therapy for early-stage gastrointestinal tract tumors. Although numerous electrosurgical knives have been developed for ESD, technical difficulties and high complication rates (bleeding and perforation) have limited their use worldwide. The grasping-type scissors forceps [clutch cutter (CC)] is the first forceps-type resection device developed with reference to hemostatic forceps. The aim was to allow easy and safe ESD throughout the gastrointestinal tract, as a biopsy technique, using one device. The CC can grasp the target tissue accurately and pull it away from the underlying muscle layer prior to energizing the tissue, for safe and effective incision and hemostasis during ESD. Reported clinical studies showed that ESD using the CC (ESD-CC) is a safe (perforation rate: 0%-3.6%; delayed bleeding rate: 0%-4.2%), technically efficient (en-bloc resection rate: 88.9%-100%), and single-device method for dissecting early-stage gastrointestinal tract tumors. The ESD-CC technique is simple and easy to learn because it can be completed simply by repeating the grasp, pull, and coagulate and/or incise actions using an electrosurgical current. The reported self-completion rate by non-experts was significantly better with the CC than with conventional knives (61.7% vs 24.5%, respectively; P < 0.001). Furthermore, the CC is used for other endoscopic therapies, such as endoscopic polypectomy for large pedunculated polyps, endoscopic myotomy for Zenker's diverticulum, endoscopic treatment of buried bumper syndrome, and endoscopic necrosectomy for wall-off pancreatic necrosis. The initial reports using CC for these therapies have shown favorable results. In this review, we describe the structural features of the CC, how to use the instrument, efficacies of ESD-CC, and other unique endoscopic therapies using the CC.

2.
World J Gastrointest Oncol ; 9(10): 416-422, 2017 Oct 15.
Article in English | MEDLINE | ID: mdl-29085568

ABSTRACT

AIM: To evaluate the clinical outcome of endoscopic submucosal dissection using the Clutch Cutter (ESDCC) in older patients. METHODS: We reviewed 232 consecutive patients with early gastric cancer who underwent ESDCC between June 2010 and February 2014 at Aso Iizuka Hospital. We divided patients into two groups according to age: Older patients (> 80 years, n = 64) and non-older patients (≤ 80 years, n = 168). We retrospectively compared the prevalence rates of pre-existing comorbidities, anticoagulant therapy, en bloc resection, mean duration of hospitalization, incidence of ESDCC-related complications, change in performance status (PS) before and after ESDCC, and financial cost of admission. RESULTS: The older group comprised 64 patients with a mean age of 84.1 years, and the non-older group comprised 168 patients with a mean age of 69.5 years. Older patients had significantly more pre-existing comorbidities than did non-older patients, specifically heart disease (P < 0.05). The en bloc resection rate in non-older patients was significantly higher than that in older patients (100% vs 95.3%, P = 0.02). There were no significant differences between the older and non-older groups in the incidence of ESDCC-related complications (i.e., postoperative bleeding and perforation) and the post-ESDCC change in PS. There were also no significant differences between the older and non-older groups in the mean duration of hospitalization (11.4 and 10.7 d, respectively) and financial cost of admission (657040 JPY and 574890 JPY, respectively). CONCLUSION: ESDCC has a good clinical outcome in older patients.

3.
World J Gastrointest Endosc ; 9(7): 334-340, 2017 Jul 16.
Article in English | MEDLINE | ID: mdl-28744346

ABSTRACT

AIM: To evaluate the efficacy and safety of endoscopic submucosal dissection (ESD) using the clutch cutter (CC) (ESD-CC) for gastric adenoma (GA). METHODS: From June 2007 to August 2015, 122 consecutive patients with histological diagnoses of GA from specimens resected by ESD-CC were enrolled in this prospective study. The CC was used for all ESD steps (marking, mucosal incision, submucosal dissection, and hemostatic treatment), and its therapeutic efficacy and safety were assessed. RESULTS: Both the en-bloc resection rate and the R0 resection rate were 100% (122/122). The mean surgical time was 77.4 min, but the time varied significantly according to tumor size and location. No patients suffered perforation. Post-ESD-CC bleeding occurred in six cases (4.9%) that were successfully resolved by endoscopic hemostatic treatment. CONCLUSION: ESD-CC is a technically efficient, safe, and easy method for resecting GA.

4.
Endoscopy ; 49(1): 54-58, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27741535

ABSTRACT

Background and study aims Endoscopic snare polypectomy with prophylactic detachable snare of large pedunculated colonic polyps (PCPs) is technically demanding. To facilitate removal of such polyps, we developed endoscopic resection using the Clutch Cutter and a detachable snare (ERCCDS). This study aimed to evaluate the efficacy and safety of the procedure. Patients and methods From April 2010 to July 2015, 14 consecutive patients who had PCPs with head > 10 mm, stalk width > 5 mm, and stalk length > 10 mm were enrolled in this single-center prospective uncontrolled study. They were treated using ERCCDS by a single endoscopist. The efficacy and safety were assessed using a database prospectively formatted from the medical records. Results The Clutch Cutter was able to cut the distal side of the stalk an adequate distance from the detachable snare under good visual control. R0 resections were obtained in all lesions. There were no immediate or delayed complications. Conclusions ERCCDS appears to be a safe, easy, and technically efficient method for large PCPs, although larger studies are needed to compare ERCCDS and standard resection.


Subject(s)
Adenoma/surgery , Colonic Neoplasms/surgery , Colonic Polyps/surgery , Endoscopy, Gastrointestinal/methods , Lymphangioma/surgery , Adenoma/pathology , Adult , Aged , Aged, 80 and over , Colonic Neoplasms/pathology , Endoscopy, Gastrointestinal/adverse effects , Endoscopy, Gastrointestinal/instrumentation , Female , Humans , Male , Middle Aged , Operative Time , Prospective Studies , Tumor Burden
5.
Endosc Int Open ; 3(5): E432-8, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26528497

ABSTRACT

BACKGROUND AND STUDY AIMS: The Clutch Cutter (CC) was developed to reduce the risk of complications related to endoscopic submucosal dissection (ESD) using knives. The CC is able to grasp and coagulate and/or incise the targeted tissue using electrosurgical current, like a biopsy technique. The aim of this study was to evaluate the efficacy and safety of ESD using the CC (ESD-CC) for early gastric cancer (EGC). PATIENTS AND METHODS: From June 2007 to March 2014, 325 consecutive patients with a diagnosis of EGC were enrolled in this prospective study. They had all satisfied the Japanese gastric cancer treatment guidelines for ESD indication, namely confirmation by preliminary endoscopy, endoscopic ultrasound, and endoscopic biopsies. The CC was used for all steps of ESD (marking, circumferential marginal incision, submucosal dissection, and hemostatic treatment). The therapeutic efficacy and safety were assessed. RESULTS: The en-bloc resection rate was 99.7 % (324/325) and the R0 resection rate was 95.3 % (310/325). The mean operating time was 97.2 minutes. Perforation during ESD-CC occurred in one case (0.3 %), which was managed with conservative medical treatment after endoscopic closure of the perforation. Post-ESD-CC bleeding occurred in 11 cases (3.4 %), which were successfully treated by endoscopic hemostatic treatment. The R0 resection rate was significantly low in tumors > 20 mm (88.9 %), and in the exclusion indication group (73.7 %). Significant differences were seen in the mean operating time, depending upon tumor size, histologic type, location, and indication criteria. CONCLUSIONS: ESD-CC is a technically efficient, safe, and easy method for resecting EGC.

SELECTION OF CITATIONS
SEARCH DETAIL
...