1.
J Bone Joint Surg Br ; 93(1): 73-7, 2011 Jan.
Article in English | MEDLINE | ID: mdl-21196547

ABSTRACT

We describe the results of a prospective case series of patients with spondylolysis, evaluating a technique of direct stabilisation of the pars interarticularis with a construct that consists of a pair of pedicle screws connected by a U-shaped modular link passing beneath the spinous process. Tightening the link to the screws compresses bone graft in the defect in the pars, providing rigid intrasegmental fixation. We have carried out this procedure on 20 patients aged between nine and 21 years with a defect of the pars at L5, confirmed on CT. The mean age of the patients was 13.9 years (9 to 21). They had a grade I or less spondylolisthesis and no evidence of intervertebral degeneration on MRI. The mean follow-up was four years (2.3 to 7.3). The patients were assessed by the Oswestry Disability Index (ODI) and a visual analogue scale (VAS). At the latest follow-up, 18 patients had an excellent clinical outcome, with a significant (p < 0.001) improvement in their ODI and VAS scores. The mean ODI score at final follow-up was 8%. Assessment of the defect by CT showed a rate of union of 80%. There were no complications involving the internal fixation. The strength of the construct removes the need for post-operative immobilisation.


Subject(s)
Bone Screws , Spondylolysis/surgery , Adolescent , Bone Transplantation/methods , Child , Disability Evaluation , Female , Follow-Up Studies , Humans , Low Back Pain/etiology , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Male , Prospective Studies , Spondylolysis/complications , Spondylolysis/diagnostic imaging , Stress, Mechanical , Tomography, X-Ray Computed , Treatment Outcome , Young Adult
2.
Injury ; 37(10): 941-5, 2006 Oct.
Article in English | MEDLINE | ID: mdl-16769071

ABSTRACT

The wire-bolt interface in an Ilizarov frame has been mechanically tested. The optimal torque to be applied to the frame locking-bolts during physiological loading has been defined. The set-up configuration was as is used clinically except a copper tube was used to simulate bone. The force-displacement curves of the Ilizarov wires are not altered by locking-bolt torque. The force in the bone model at which pre-tension is lost increases as the locking-bolts are tightened to 14 Nm torque, but decreases if torque exceeds 14 Nm. Thus, 14 Nm is the optimal locking-bolt torque in frame. The relationship between pre-tension versus load for different locking-bolt torques arises because at low and high clamping torques poor wire holding and plastic deformation respectively occur. Wire damage was seen under light and electron microscopy. Clinically, over or under-tightening locking-bolts will cause loss of pre-tension, reduction in frame stiffness and excessive movement at the fracture site, which may be associated with delayed union.


Subject(s)
External Fixators , Ilizarov Technique/instrumentation , Materials Testing/methods , Biomechanical Phenomena , Equipment Failure , Materials Testing/instrumentation , Torque