Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Radiat Oncol ; 17(1): 38, 2022 Feb 22.
Article in English | MEDLINE | ID: mdl-35193630

ABSTRACT

PURPOSE: Boosting dominant intra-prostatic lesions (DILs) has the potential to increase the therapeutic ratio in prostate cancer radiotherapy. In this study, employing 5-fraction stereotactic ablative radiotherapy (SABR) volumetric modulated arc therapy (VMAT) to deliver 40 Gy to the prostate clinical target volume (CTV) while boosting the DIL up to 50 Gy was evaluated for patients before and after rectal spacer insertion. MATERIALS AND METHODS: 24 Computed Tomography (CT) scans of 12 prostate cancer patients with unfavourable intermediate or high risk prostate cancer were employed in this study. At least two treatment plans were generated for each patient to compare pre- and post-spacer insertion plans. Plans were evaluated for target coverage, organs-at-risk doses, and the achievable boost dose level. RESULTS: The CTV coverage was significantly better in plans with a spacer, V40Gy 98.4% versus 97.0% (p = 0.012). Using spacers significantly reduced rectal dose in all 12 patients in this study. It was possible to boost DIL to 50 Gy to without violating dose constraints in 6 of 12 patients and to 47.5 Gy in 3 patients post-spacer insertion. For 3 patients (25%) it was not possible to boost DIL above 45 Gy even with a spacer in situ. Without a spacer, for 6 patient (50%) clinically acceptable plan were only achieved when the DIL dose was lowered to 45 Gy. In five of these 6 patients the dose limiting structure was the urethra (urethra planning risk volume V45Gy [cc] ≤ 0.1 cc constraint). CONCLUSIONS: Clinically acceptable plans for 5 fraction SABR, 40 Gy to the prostate CTV, with a SIB to DIL (45-50 Gy) were achieved. The boost dose achieved was DIL location dependent and primarily affected by DIL's proximity to the urethra. Compared to plans before spacer insertion, higher DIL dose were achieved with spacer in situ for 25% of the patients. Moreover, significant reduction in rectal dose and better target coverage were also achieved for all patients with spacers in situ.


Subject(s)
Adenocarcinoma/radiotherapy , Prostatic Neoplasms/radiotherapy , Radiation Dose Hypofractionation , Radiosurgery/instrumentation , Radiotherapy, Intensity-Modulated/instrumentation , Humans , Male , Rectum
2.
Br J Radiol ; 93(1115): 20200775, 2020 Nov 01.
Article in English | MEDLINE | ID: mdl-32880475

ABSTRACT

OBJECTIVES: The isotope bone scan (IBS) is the gold-standard imaging modality for detecting skeletal metastases as part of prostate cancer staging. However, its clinical utility for assessing skeletal metastatic burden is limited due to the need for subjective interpretation. We designed and tested a novel custom software tool, the Metastatic Bone Scan Tool (MetsBST), aimed at improving interpretation of IBSs, and compared its performance with that of an established software programme. METHODS: We used IBS images from 62 patients diagnosed with prostate cancer and suspected bone metastases to design and implement MetsBST in MATLAB by defining thresholds used to identify the texture and size of metastatic bone lesions. The results of MetsBST were compared with those of the commercially available automated Bone Scan Index (aBSI) with regression analysis. RESULTS: There was strong agreement between the MetsBST and aBSI results (R2 = 0.9189). In a subregional analysis, MetsBST quantified the extent of metastatic disease in multiple bone sites in patients receiving multimodality therapy (radium-223 and external beam radiotherapy) to illustrate the differences in bone metastatic response to different treatments. CONCLUSION: The results of MetsBST and the commercial software aBSI were highly consistent. MetsBST introduces novel clinical utility by its ability to differentiate between the responses of different bone metastases to multimodality therapies. ADVANCES IN KNOWLEDGE: MetsBST reduces the variability in assessment of tumour burden caused by subjective interpretation. Therefore, it is a useful aid to physicians reporting nuclear medicine scans, and may improve decision-making in the treatment of metastatic prostate cancer.


Subject(s)
Bone Neoplasms/diagnostic imaging , Bone Neoplasms/secondary , Bone and Bones/diagnostic imaging , Prostatic Neoplasms/pathology , Software Design , Aged , Aged, 80 and over , Bone Neoplasms/pathology , Bone Neoplasms/radiotherapy , Etidronic Acid , Humans , Male , Middle Aged , Organotechnetium Compounds , Prostatic Neoplasms, Castration-Resistant/pathology , Radiopharmaceuticals , Regression Analysis , Tumor Burden , Urinary Bladder/diagnostic imaging
3.
Radiat Oncol ; 14(1): 237, 2019 Dec 26.
Article in English | MEDLINE | ID: mdl-31878967

ABSTRACT

BACKGROUND: In this study, a novel pelvic phantom was developed and used to assess the visibility and presence of artefacts from different types of commercial fiducial markers (FMs) on multi-modality imaging relevant to prostate cancer. METHODS AND MATERIALS: The phantom was designed with 3D printed hollow cubes in the centre. These cubes were filled with gel to mimic the prostate gland and two parallel PVC rods were used to mimic bones in the pelvic region. Each cube was filled with gelatine and three unique FMs were positioned with a clinically-relevant spatial distribution. The FMs investigated were; Gold Marker (GM) CIVCO, GM RiverPoint, GM Gold Anchor (GA) line and ball shape, and polymer marker (PM) from CIVCO. The phantom was scanned using several imaging modalities typically used to image prostate cancer patients; MRI, CT, CBCT, planar kV-pair, ExacTrac, 6MV, 2.5MV and integrated EPID imaging. The visibility of the markers and any observed artefacts in the phantom were compared to in-vivo scans of prostate cancer patients with FMs. RESULTS: All GMs were visible in volumetric scans, however, they also had the most visible artefacts on CT and CBCT scans, with the magnitude of artefacts increasing with FM size. PM FMs had the least visible artefacts in volumetric scans but they were not visible on portal images and had poor visibility on lateral kV images. The smallest diameter GMs (GA) were the most difficult GMs to identify on lateral kV images. CONCLUSION: The choice between different FMs is also dependent on the adopted IGRT strategy. PM was found to be superior to investigated gold markers in the most commonly used modalities in the management of prostate cancer; CT, CBCT and MRI imaging.


Subject(s)
Cone-Beam Computed Tomography/standards , Fiducial Markers , Magnetic Resonance Imaging/standards , Multimodal Imaging/standards , Phantoms, Imaging , Prostatic Neoplasms/radiotherapy , Radiotherapy, Image-Guided/standards , Artifacts , Cone-Beam Computed Tomography/instrumentation , Gold/analysis , Humans , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/instrumentation , Male , Multimodal Imaging/instrumentation , Organs at Risk/radiation effects , Prostatic Neoplasms/diagnostic imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/instrumentation , Radiotherapy, Intensity-Modulated/methods , Signal-To-Noise Ratio
4.
Int J Radiat Oncol Biol Phys ; 105(2): 448-456, 2019 10 01.
Article in English | MEDLINE | ID: mdl-31254658

ABSTRACT

PURPOSE: To explore the role of Computed tomography (CT)-based radiomics features in prostate cancer risk stratification. METHODS AND MATERIALS: The study population consisted of 506 patients with prostate cancer collected from a clinically annotated database. After applying exclusion criteria, 342 patients were included in the final analysis. CT-based radiomics features were extracted from planning CT scans for prostate gland-only structure, and machine learning was used to train models for Gleason score (GS) and risk group (RG) classifications. Repeated cross-validation was used. The discriminatory performance of the developed models was assessed using receiver operating characteristic area under the curve (AUC) analysis. RESULTS: Classifiers using CT-based radiomics features distinguished between GS ≤ 6 versus GS ≥ 7 with AUC = 0.90 and GS 7(3 + 4) versus GS 7(4 + 3) with AUC = 0.98. Developed classifiers also showed excellent performance in distinguishing low versus high RG (AUC = 0.96) and low versus intermediate RG (AUC = 1.00), but poorer performance was observed for GS 7 versus GS > 7 (AUC = 0.69). An overall modest performance was observed for validation on holdout data sets with the highest AUC of 0.75 for classifiers of low versus high RG and an AUC of 0.70 for GS 7 versus GS > 7. CONCLUSIONS: Our results show that radiomics features from routinely acquired planning CT scans could provide insights into prostate cancer aggressiveness in a noninvasive manner. Assessing models on training data sets, the classifiers were especially accurate in discerning high-risk from low-risk patients and in classifying GS 7 versus GS > 7 and GS 7(3 + 4) versus G7(4 + 3); however, classifiers were less adept at distinguishing high RG versus intermediate RG. External validation and prospective studies are warranted to verify the presented findings. These findings could potentially guide targeted radiation therapy strategies in radical intent radiation therapy for prostate cancer.


Subject(s)
Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Tomography, X-Ray Computed , Area Under Curve , Datasets as Topic , Humans , Male , Neoplasm Grading , Prostate/diagnostic imaging , Prostatic Neoplasms/radiotherapy , ROC Curve , Radiotherapy Planning, Computer-Assisted , Reproducibility of Results , Risk Assessment/methods
5.
Radiat Oncol ; 12(1): 204, 2017 Dec 28.
Article in English | MEDLINE | ID: mdl-29282134

ABSTRACT

BACKGROUND: Preclinical radiation biology has become increasingly sophisticated due to the implementation of advanced small animal image guided radiation platforms into laboratory investigation. These small animal radiotherapy devices enable state-of-the-art image guided therapy (IGRT) research to be performed by combining high-resolution cone beam computed tomography (CBCT) imaging with an isocentric irradiation system. Such platforms are capable of replicating modern clinical systems similar to those that integrate a linear accelerator with on-board CBCT image guidance. METHODS: In this study, we present a dosimetric evaluation of the small animal radiotherapy research platform (SARRP, Xstrahl Inc.) focusing on small field dosimetry. Physical dosimetry was assessed using ion chamber for calibration and radiochromic film, investigating the impact of beam focus size on the dose rate output as well as beam characteristics (beam shape and penumbra). Two film analysis tools) have been used to assess the dose output using the 0.5 mm diameter aperture. RESULTS: Good agreement (between 1.7-3%) was found between the measured physical doses and the data provided by Xstrahl for all apertures used. Furthermore, all small field dosimetry data are in good agreement for both film reading methods and with our Monte Carlo simulations for both focal spot sizes. Furthermore, the small focal spot has been shown to produce a more homogenous beam with more stable penumbra over time. CONCLUSIONS: FilmQA Pro is a suitable tool for small field dosimetry, with a sufficiently small sampling area (0.1 mm) to ensure an accurate measurement. The electron beam focus should be chosen with care as this can potentially impact on beam stability and reproducibility.


Subject(s)
Cone-Beam Computed Tomography/instrumentation , Phantoms, Imaging , Radiobiology , Radiotherapy Planning, Computer-Assisted/instrumentation , Animals , Monte Carlo Method
6.
Radiat Oncol ; 12(1): 124, 2017 Aug 04.
Article in English | MEDLINE | ID: mdl-28778178

ABSTRACT

BACKGROUND: Traditional CTV-PTV margin recipes are not generally applicable in the situation of stereotactic ablative radiotherapy (SABR) treatments of multiple target volumes with a single isocentre. In this work, we present a novel geometric method of margin derivation based on CBCT-derived anatomical data. METHODS: Twenty patients with high-risk localized prostate cancer were selected for retrospective review. Individual volumes of interest (prostate, prostate and seminal vesicles and pelvic lymph nodes) were delineated on five representative CBCTs and registered to the planning CT using two registration protocols: bone match or prostate-based soft tissue match. Margins were incrementally expanded around composite CTV structures until 95% overlap was achieved. RESULTS: CTV-PTV margins of 5.2, 6.5 and 7.6 mm were required for prostate, prostate and seminal vesicles and pelvic lymph nodes respectively using a prostate matching protocol. For the prostate and seminal vesicle structures, margins calculated using our method displayed good agreement with a conventional margin recipe (within ±1.0 mm). CONCLUSIONS: We have presented an alternative method of CTV-PTV margin derivation that is applicable to SABR treatments with more than one isocentric target. These results have informed an institutional trial of prostate and pelvic nodal SABR in men with high-risk localized prostate cancer.


Subject(s)
Cone-Beam Computed Tomography/methods , Lymphatic Metastasis/radiotherapy , Prostatic Neoplasms/radiotherapy , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Humans , Lymph Nodes/radiation effects , Male , Pelvis , Radiotherapy, Image-Guided/methods , Retrospective Studies
7.
Radiat Oncol ; 12(1): 53, 2017 Mar 14.
Article in English | MEDLINE | ID: mdl-28288658

ABSTRACT

BACKGROUND: Low-dose-rate permanent prostate brachytherapy (PPB) is an attractive treatment option for patients with localised prostate cancer with excellent outcomes. As standard CT-based post-implant dosimetry often correlates poorly with late treatment-related toxicity, this exploratory (proof of concept) study was conducted to investigate correlations between radiation - induced DNA damage biomarker levels, and acute and late bowel, urinary, and sexual toxicity. METHODS: Twelve patients treated with 125I PPB monotherapy (145Gy) for prostate cancer were included in this prospective study. Post-implant CT based dosimetry assessed the minimum dose encompassing 90% (D90%) of the whole prostate volume (global), sub-regions of the prostate (12 sectors) and the near maximum doses (D0.1cc, D2cc) for the rectum and bladder. Six blood samples were collected from each patient; pre-treatment, 1 h (h), 4 h, 24 h post-implant, at 4 weeks (w) and at 3 months (m). DNA double strand breaks were investigated by staining the blood samples with immunofluorescence antibodies to γH2AX and 53BP1 proteins (γH2AX/53BP1). Patient self-scored quality of life from the Expanded Prostate Cancer Index Composite (EPIC) were obtained at baseline, 1 m, 3 m, 6 m, 9 m, 1 year (y), 2y and 3y post-treatment. Spearman's correlation coefficients were used to evaluate correlations between temporal changes in γH2AX/53BP1, dose and toxicity. RESULTS: The minimum follow up was 2 years. Population mean prostate D90% was 144.6 ± 12.1 Gy and rectal near maximum dose D0.1cc = 153.0 ± 30.8 Gy and D2cc = 62.7 ± 12.1 Gy and for the bladder D0.1cc = 123.1 ± 27.0 Gy and D2cc = 70.9 ± 11.9 Gy. Changes in EPIC scores from baseline showed high positive correlation between acute toxicity and late toxicity for both urinary and bowel symptoms. Increased production of γH2AX/53BP1 at 24 h relative to baseline positively correlated with late bowel symptoms. Overall, no correlations were observed between dose metrics (prostate global or sector doses) and γH2AX/53BP1 foci counts. CONCLUSIONS: Our results show that a prompt increase in γH2AX/53BP1foci at 24 h post-implant relative to baseline may be a useful measure to assess elevated risk of late RT - related toxicities for PPB patients. A subsequent investigation recruiting a larger cohort of patients is warranted to verify our findings.


Subject(s)
Biomarkers/blood , Brachytherapy , Histones/blood , Prostatic Neoplasms/blood , Quality of Life , Tumor Suppressor p53-Binding Protein 1/blood , Aged , Follow-Up Studies , Humans , Male , Middle Aged , Neoplasm Grading , Prognosis , Prospective Studies , Prostatic Neoplasms/pathology , Prostatic Neoplasms/radiotherapy , Radiotherapy Dosage , Survival Rate
8.
Radiat Oncol ; 11(1): 155, 2016 Nov 24.
Article in English | MEDLINE | ID: mdl-27881187

ABSTRACT

BACKGROUND: The purpose of this study is to find the optimal planning settings for prostate SABR-VMAT for high-risk prostate cancer patients irradiated to prostate only (PO) or prostate and pelvic lymph nodes (PPLN). METHODS: For 10 patients, plans using 6MV flattened, flattening-filter-free (FFF) 6MV (6 F) and FFF 10MV (10 F) photon beams with full and partial arc arrangements were generated and compared. The prescribed dose was 40Gy to the prostate with 25Gy to the PLN in 5 fractions. Plans were then evaluated for PTV coverage, dose fall-off, and OAR doses. The number of monitor units and the treatment delivery times were also compared. Statistical differences were evaluated using a paired sample Wilcoxon signed rank test with a significance level of 0.05%. RESULTS: A total of 150 plans were generated for this study. Acceptable PO plans were obtained using single arcs, while two arcs were necessary for PPLN. All plans were highly conformal (CI ≥1.3 and CN ≥0.90) with no significant differences in the PTV dose coverage. 6MV plans required significantly longer treatment time and had higher dose spillage compared to FFF plans. Superior plans were obtained using 10 F 300° partial arcs for PO with the lowest rectal dose, dose spillage and the shortest treatment times. For PPLN, 6 F and 10 F plans were equivalent. CONCLUSIONS: SABR-VMAT with FFF photon beams offers a clear benefit with respect to shorter treatment delivery times and reduced dose spillage. Class solutions using a single 10 F 300° arc for PO and two 10 F or 6 F partial 300° arcs for PPLN are proposed.


Subject(s)
Prostatic Neoplasms/radiotherapy , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Humans , Lymph Nodes/radiation effects , Male , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/methods
9.
Int J Radiat Oncol Biol Phys ; 93(1): 190-5, 2015 Sep 01.
Article in English | MEDLINE | ID: mdl-26094125

ABSTRACT

PURPOSE: The purpose of this study was to verify clinical target volume--planning target volume (CTV-PTV) margins in single vocal cord irradiation (SVCI) of T1a larynx tumors and characterize inter- and intrafraction target motion. METHODS AND MATERIALS: For 42 patients, a single vocal cord was irradiated using intensity modulated radiation therapy at a total dose of 58.1 Gy (16 fractions × 3.63 Gy). A daily cone beam computed tomography (CBCT) scan was performed to online correct the setup of the thyroid cartilage after patient positioning with in-room lasers (interfraction motion correction). To monitor intrafraction motion, CBCT scans were also acquired just after patient repositioning and after dose delivery. A mixed online-offline setup correction protocol ("O2 protocol") was designed to compensate for both inter- and intrafraction motion. RESULTS: Observed interfraction, systematic (Σ), and random (σ) setup errors in left-right (LR), craniocaudal (CC), and anteroposterior (AP) directions were 0.9, 2.0, and 1.1 mm and 1.0, 1.6, and 1.0 mm, respectively. After correction of these errors, the following intrafraction movements derived from the CBCT acquired after dose delivery were: Σ = 0.4, 1.3, and 0.7 mm, and σ = 0.8, 1.4, and 0.8 mm. More than half of the patients showed a systematic non-zero intrafraction shift in target position, (ie, the mean intrafraction displacement over the treatment fractions was statistically significantly different from zero; P<.05). With the applied CTV-PTV margins (for most patients 3, 5, and 3 mm in LR, CC, and AP directions, respectively), the minimum CTV dose, estimated from the target displacements observed in the last CBCT, was at least 94% of the prescribed dose for all patients and more than 98% for most patients (37 of 42). The proposed O2 protocol could effectively reduce the systematic intrafraction errors observed after dose delivery to almost zero (Σ = 0.1, 0.2, 0.2 mm). CONCLUSIONS: With adequate image guidance and CTV-PTV margins in LR, CC, and AP directions of 3, 5, and 3 mm, respectively, excellent target coverage in SVCI could be ensured.


Subject(s)
Laryngeal Neoplasms/radiotherapy , Movement , Radiotherapy, Intensity-Modulated/methods , Vocal Cords , Cone-Beam Computed Tomography/methods , Dose Fractionation, Radiation , Feasibility Studies , Glottis , Humans , Laryngeal Neoplasms/diagnostic imaging , Laryngeal Neoplasms/pathology , Neoplasm Staging , Organs at Risk/diagnostic imaging , Organs at Risk/radiation effects , Patient Positioning , Radiation Injuries/prevention & control , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Setup Errors
10.
Radiother Oncol ; 112(1): 17-22, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24825176

ABSTRACT

PURPOSE: To investigate the effects of using volumetric modulated arc therapy (VMAT) and/or voluntary moderate deep inspiration breath-hold (vmDIBH) in the radiation therapy (RT) of left-sided breast cancer including the regional lymph nodes. MATERIALS AND METHODS: For 13 patients, four treatment combinations were compared; 3D-conformal RT (i.e., forward IMRT) in free-breathing 3D-CRT(FB), 3D-CRT(vmDIBH), 2 partial arcs VMAT(FB), and VMAT(vmDIBH). Prescribed dose was 42.56 Gy in 16 fractions. For 10 additional patients, 3D-CRT and VMAT in vmDIBH only were also compared. RESULTS: Dose conformity, PTV coverage, ipsilateral and total lung doses were significantly better for VMAT plans compared to 3D-CRT. Mean heart dose (D(mean,heart)) reduction in 3D-CRT(vmDIBH) was between 0.9 and 8.6 Gy, depending on initial D(mean,heart) (in 3D-CRT(FB) plans). VMAT(vmDIBH) reduced the D(mean,heart) further when D(mean,heart) was still >3.2 Gy in 3D-CRT(vmDIBH). Mean contralateral breast dose was higher for VMAT plans (2.7 Gy) compared to 3DCRT plans (0.7 Gy). CONCLUSIONS: VMAT and 3D-CRT(vmDIBH) significantly reduced heart dose for patients treated with locoregional RT of left-sided breast cancer. When Dmean,heart exceeded 3.2 Gy in 3D-CRT(vmDIBH) plans, VMAT(vmDIBH) resulted in a cumulative heart dose reduction. VMAT also provided better target coverage and reduced ipsilateral lung dose, at the expense of a small increase in the dose to the contralateral breast.


Subject(s)
Breast Neoplasms/radiotherapy , Breath Holding , Heart Diseases/prevention & control , Lung Diseases/prevention & control , Lymph Nodes , Mastectomy, Segmental , Radiation Injuries/prevention & control , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Adult , Breast Neoplasms/pathology , Cardiotoxicity/etiology , Cardiotoxicity/prevention & control , Female , Heart Diseases/etiology , Humans , Lung Diseases/etiology , Middle Aged , Radiation Injuries/etiology , Radiometry , Radiotherapy Dosage , Radiotherapy, Adjuvant/adverse effects , Radiotherapy, Adjuvant/methods , Radiotherapy, Conformal/methods , Radiotherapy, Image-Guided/methods , Treatment Outcome
11.
Acta Oncol ; 53(6): 788-94, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24689645

ABSTRACT

BACKGROUND: In a selective group of patients accelerated partial breast irradiation (APBI) might be applied after conservative breast surgery to reduce the amount of irradiated healthy tissue. The role of volumetric modulated arc therapy (VMAT) and voluntary moderately deep inspiration breath-hold (vmDIBH) techniques in further reducing irradiated healthy--especially heart--tissue is investigated. MATERIAL AND METHODS: For 37 partial breast planning target volumes (PTVs), three-dimensional conformal radiotherapy (3D-CRT) (3-5 coplanar or non-coplanar 6 and/or 10 MV beams) and VMAT (two partial 6 MV arcs) plans were made on CTs acquired in free-breathing (FB) and/or in vmDIBH. Dose-volume parameters for the PTV, heart, lungs, and breasts were compared. RESULTS: Better dose conformity was achieved with VMAT compared to 3D-CRT (conformity index 1.24±0.09 vs. 1.49±0.20). Non-PTV ipsilateral breast receiving ≥50% of the prescribed dose was on average reduced by 28% in VMAT plans compared to 3D-CRT plans. Mean heart dose (MHD) reduced from 2.0 (0.1-5.1) Gy in 3D-CRT(FB) to 0.6 (0.1-1.6) Gy in VMAT(vmDIBH). VMAT is beneficial for MHD reduction if MHD with 3D-CRT exceeds 0.5Gy. Cardiac dose reduction as a result of VMAT increases with increasing initial MHD, and adding vmDIBH reduces the cardiac dose further. Mean dose to the ipsilateral lung decreased from 3.7 (0.7-8.7) to 1.8 (0.5-4.0) Gy with VMAT(vmDIBH) compared to 3D-CRT(FB). VMAT resulted in a slight increase in the contralateral breast dose (DMean) always remaining <1.9 Gy). CONCLUSIONS: For APBI patients, VMAT improves PTV dose conformity and delivers lower doses to the ipsilateral breast and lung compared to 3D-CRT. This goes at the cost of a slight but acceptable increase of the contralateral breast dose. VMAT reduces cardiac dose if MHD exceeds 0.5 Gy for 3D-CRT. Adding vmDIBH results in a further reduction of heart and ipsilateral lung dose.


Subject(s)
Breast Neoplasms/radiotherapy , Organs at Risk , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Radiotherapy, Intensity-Modulated/methods , Adult , Breath Holding , Female , Humans , Mastectomy, Segmental , Radiotherapy, Adjuvant/methods , Retrospective Studies , Tomography, X-Ray Computed
12.
Acta Oncol ; 53(2): 278-85, 2014 Feb.
Article in English | MEDLINE | ID: mdl-23879644

ABSTRACT

PURPOSE: To investigate the robustness of single vocal cord intensity modulated radiation therapy (IMRT) treatment plans for set-up errors, respiration, and deformation. MATERIAL AND METHODS: Four-dimensional computed tomography (4D-CT) scans of 10 early glottic carcinoma patients, previously treated with conventional techniques, were used in this simulation study. For each patient a pre-treatment 4D-CT was used for IMRT planning, generating a reference dose distribution. Prescribed PTV dose was 66 Gy. The impact of systematic set-up errors was simulated by applying shifts of ± 2 mm to the planning CT scans, followed by dose re-calculation with original beam segments, MUs, etc. Effects of respiration and deformation were determined utilizing extreme inhale and exhale CT scans, and repeat scans acquired after 22 Gy, 44 Gy, and 66 Gy, respectively. All doses were calculated using Monte Carlo dose simulations. RESULTS: Considering all investigated geometrical perturbations, reductions in the clinical target volume (CTV) V95%, D98%, D2%, and generalized equivalent uniform dose (gEUD) were limited to 1.2 ± 2.2%, 2.4 ± 2.9%, 0.2 ± 1.8%, and 0.6 ± 1.1 Gy, respectively. The near minimum dose, D98%, was always higher than 89%, and gEUD always remained higher than 66 Gy. Planned contra-lateral (CL) vocal cord DMean, gEUD, and V40 Gy were 38.2 ± 6.0 Gy, 43.4 ± 5.6 Gy, and 42.7 ± 14.9%. With perturbations these values changed by -0.1 ± 4.3 Gy, 0.1 ± 4.0 Gy, and -1.0 ± 9.6%, respectively. CONCLUSIONS: On average, CTV dose reductions due to geometrical perturbations were very low, and sparing of the CL vocal cord was maintained. In a few observations (6 of 103 simulated situations), the near-minimum CTV-dose was around 90%, requiring attention in deciding on a future clinical protocol.


Subject(s)
Carcinoma/radiotherapy , Laryngeal Neoplasms/radiotherapy , Radiotherapy, Image-Guided/methods , Radiotherapy, Intensity-Modulated/methods , Vocal Cords , Four-Dimensional Computed Tomography , Humans , Monte Carlo Method , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Retrospective Studies
13.
Int J Radiat Oncol Biol Phys ; 82(2): 989-97, 2012 Feb 01.
Article in English | MEDLINE | ID: mdl-21300449

ABSTRACT

PURPOSE: We have been developing an image-guided single vocal cord irradiation technique to treat patients with stage T1a glottic carcinoma. In the present study, we compared the dose coverage to the affected vocal cord and the dose delivered to the organs at risk using conventional, intensity-modulated radiotherapy (IMRT) coplanar, and IMRT non-coplanar techniques. METHODS AND MATERIALS: For 10 patients, conventional treatment plans using two laterally opposed wedged 6-MV photon beams were calculated in XiO (Elekta-CMS treatment planning system). An in-house IMRT/beam angle optimization algorithm was used to obtain the coplanar and non-coplanar optimized beam angles. Using these angles, the IMRT plans were generated in Monaco (IMRT treatment planning system, Elekta-CMS) with the implemented Monte Carlo dose calculation algorithm. The organs at risk included the contralateral vocal cord, arytenoids, swallowing muscles, carotid arteries, and spinal cord. The prescription dose was 66 Gy in 33 fractions. RESULTS: For the conventional plans and coplanar and non-coplanar IMRT plans, the population-averaged mean dose ± standard deviation to the planning target volume was 67 ± 1 Gy. The contralateral vocal cord dose was reduced from 66 ± 1 Gy in the conventional plans to 39 ± 8 Gy and 36 ± 6 Gy in the coplanar and non-coplanar IMRT plans, respectively. IMRT consistently reduced the doses to the other organs at risk. CONCLUSIONS: Single vocal cord irradiation with IMRT resulted in good target coverage and provided significant sparing of the critical structures. This has the potential to improve the quality-of-life outcomes after RT and maintain the same local control rates.


Subject(s)
Laryngeal Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Radiotherapy, Intensity-Modulated/methods , Vocal Cords , Algorithms , Arytenoid Cartilage/diagnostic imaging , Dose Fractionation, Radiation , Humans , Laryngeal Muscles/diagnostic imaging , Laryngeal Neoplasms/diagnostic imaging , Monte Carlo Method , Organs at Risk/diagnostic imaging , Pharyngeal Muscles/diagnostic imaging , Radiation Injuries/prevention & control , Radiography , Tumor Burden , Vocal Cords/diagnostic imaging
14.
Radiother Oncol ; 101(3): 415-9, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21663989

ABSTRACT

INTRODUCTION: The treatment of choice for early glottic cancer is still being debated; ultimately it relies on the functional outcome. This paper reports on a novel sparing 4D conformal technique for single vocal cord irradiation (SVCI). MATERIAL AND METHODS: The records of 164 T1a patients with SCC of the vocal cord, irradiated in the Erasmus MC between 2000 and 2008, were analyzed for local control and overall survival. The quality of life was determined by EORTC H&N35 questionnaires. Also the VHI (voice handicap index), and the TSH (thyroid stimulating hormone) blood levels, were established. On-line image guided SVCI, using cone beam CT or stereotactic radiation therapy (SRT) techniques, were developed. RESULTS: A LC rate at five-years of 93% and a VHI of 12.7 (0-63) was determined. It appeared feasible to irradiate one vocal cord within 1-2mm accuracy. This way sparing of the contralateral (CL) vocal cord and CL normal tissues, could be achieved. CONCLUSIONS: Given the accuracy (1-2mm) and small volume disease (CTV limited to one vocal cord), for the use of stereotactic RT techniques SVCI with large fraction sizes is currently being investigated in clinic. It is argued that hypofractionated SVCI can be a competitive alternative to laser surgery.


Subject(s)
Carcinoma, Squamous Cell/radiotherapy , Glottis , Laryngeal Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/methods , Vocal Cords/radiation effects , Carcinoma, Squamous Cell/mortality , Cone-Beam Computed Tomography , Humans , Laryngeal Neoplasms/mortality , Radiosurgery , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Image-Guided
15.
Radiother Oncol ; 93(1): 8-13, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19524313

ABSTRACT

BACKGROUND AND PURPOSE: We are developing a technique for highly focused vocal cord irradiation in early glottic carcinoma to optimally treat a target volume confined to a single cord. This technique, in contrast with the conventional methods, aims at sparing the healthy vocal cord. As such a technique requires sub-mm daily targeting accuracy to be effective, we investigate the accuracy achievable with on-line kV-cone beam CT (CBCT) corrections. MATERIALS AND METHODS: CBCT scans were obtained in 10 early glottic cancer patients in each treatment fraction. The grey value registration available in X-ray volume imaging (XVI) software (Elekta, Synergy) was applied to a volume of interest encompassing the thyroid cartilage. After application of the thus derived corrections, residue displacements with respect to the planning CT scan were measured at clearly identifiable relevant landmarks. The intra- and inter-observer variations were also measured. RESULTS: While before correction the systematic displacements of the vocal cords were as large as 2.4+/-3.3mm (cranial-caudal population mean+/-SD Sigma), daily CBCT registration and correction reduced these values to less than 0.2+/-0.5mm in all directions. Random positioning errors (SD sigma) were reduced to less than 1mm. Correcting only for translations and not for rotations did not appreciably affect this accuracy. The residue random displacements partly stem from intra-observer variations (SD=0.2-0.6mm). CONCLUSION: The use of CBCT for daily image guidance in combination with standard mask fixation reduced systematic and random set-up errors of the vocal cords to <1mm prior to the delivery of each fraction dose. Thus, this facilitates the high targeting precision required for a single vocal cord irradiation.


Subject(s)
Cone-Beam Computed Tomography/methods , Laryngeal Neoplasms/radiotherapy , Online Systems , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated , Vocal Cords/radiation effects , Cone-Beam Computed Tomography/instrumentation , Female , Humans , Laryngeal Neoplasms/diagnostic imaging , Male , Observer Variation , Radiation Injuries/prevention & control , Radiotherapy Dosage , Radiotherapy, Computer-Assisted/methods , Sampling Studies , Vocal Cords/diagnostic imaging
16.
Radiother Oncol ; 89(1): 19-27, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18556079

ABSTRACT

BACKGROUND AND PURPOSE: To quantify respiratory motion of the vocal cords during normal respiration using 4D-CT. The final goal is to develop a technique for single vocal cord irradiation (SVCI) in early glottic carcinoma. Sparing the non-involved cord and surrounding structures has the potential to preserve voice quality and allow re-irradiation of recurrent and second primary tumors. MATERIAL AND METHODS: Four-dimensional CTs of 1mm slice thickness from 10 early glottic carcinoma patients were acquired. The lateral dimensions of the air gap separating the vocal cords were measured anteriorly, at mid-level and posteriorly at each phase of the 4D-CTs. The corresponding anterior-posterior gaps were similarly measured. Cranio-caudal vocal cords movements during breathing were derived from the shifts of the arythenoids. RESULTS: The population-averaged mean gap size+/-the corresponding standard deviation due to breathing (SD(B)) for the lateral gaps was 5.8+/-0.7mm anteriorly, 8.7+/-0.9mm at mid-level, and 11.0+/-1.3mm posteriorly. Anterior-posterior gap values were 21.7+/-0.7mm, while cranio-caudal shift SD(B) was 0.8mm. CONCLUSION: Vocal cords breathing motions were found to be small relative to their separation. Hence, breathing motion does not seem to be a limiting factor for SVCI.


Subject(s)
Laryngeal Neoplasms/diagnostic imaging , Laryngeal Neoplasms/radiotherapy , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Vocal Cords/diagnostic imaging , Voice Quality , Aged , Female , Humans , Laryngeal Neoplasms/pathology , Male , Middle Aged , Treatment Outcome , Vocal Cords/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...