1.
Pacing Clin Electrophysiol ; 41(2): 136-142, 2018 02.
Article in English | MEDLINE | ID: mdl-29266324

ABSTRACT

BACKGROUND: "Twiddler's syndrome" occurs when a patient consciously or subconsciously manipulates their pacemaker/defibrillator pulse generator, often resulting in lead dislodgement and device system malfunction. Once dislodgement has occurred, corrective measures include resecuring the system to the pectoralis fascia with redundant anchoring sutures. Unfortunately, patients with Twiddler's syndrome tend to have a high rate of recurrence. This study presents a case series of patients with Twiddler's syndrome and evaluates the strategy of using a nonabsorbable antimicrobial pouch to prevent recurrent lead dislodgement events. METHODS: Pacemaker and defibrillator operative reports were reviewed at a single institution over a time period of 16 years. Historical, fluoroscopic, and intraoperative findings were used to identify 21 patients with strong evidence for Twiddler's syndrome. Patient charts were retrospectively analyzed, and a cohort of 13 patients who received a nonabsorbable antimicrobial pouch was compared to a cohort of eight patients who received other corrective measures. RESULTS: The rate of "retwiddling" events was 0% in the antimicrobial pouch group versus 50% in the suture-only group (P < 0.05). CONCLUSIONS: Among patients requiring device system revision for Twiddler's syndrome, the use of nonabsorbable antimicrobial pouches was associated with significantly fewer recurrences of lead dislodgement events.


Subject(s)
Anti-Bacterial Agents/administration & dosage , Defibrillators, Implantable , Pacemaker, Artificial , Prostheses and Implants , Aged , Equipment Failure , Female , Humans , Male , Middle Aged , Pectoralis Muscles , Polyethylene Terephthalates , Recurrence , Retrospective Studies , Syndrome
2.
Case Rep Cardiol ; 2014: 976494, 2014.
Article in English | MEDLINE | ID: mdl-24826315

ABSTRACT

We report a 73-year-old male with late onset monomorphic ventricular tachycardia following mitral valve repair (MVR). Typically, injury to epicardial arteries following mitral valve repair/replacement presents immediately as ventricular tachycardia/fibrillation, difficulty weaning from cardiopulmonary bypass, worsening ECG changes, increasing cardiac biomarkers, or new wall motion abnormalities. Our case illustrates a "late complication" of a distorted circumflex artery following mitral valve repair and the importance of early diagnostic angiography and percutaneous intervention.