Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Eur J Radiol ; 106: 26-31, 2018 Sep.
Article in English | MEDLINE | ID: mdl-30150047

ABSTRACT

BACKGROUND: We previously reported the Screening with tomosynthesis or standard mammography-2 (STORM-2) trial, showing that tomosynthesis (3D-mammography) screening detected more cancers than 2D-mammography in double-reading practice. In this study, we report reader-specific detection measures for radiologists who performed the screen-reading in this trial. METHODS: This is a sub-study of the STORM-2 trial which prospectively integrated 3D-mammography with acquired or synthetized 2D-mammograms in parallel double-reading arms. Asymptomatic women ≥49 years who attended population-based screening (Trento, 2013-2015) were recruited. Screening participants were recalled at any positive sequential screen-read in either reading arm of the trial. Radiologist-specific detection measures were calculated for each of seven radiologists who performed screen-reads: number of detected cancers, proportion of true-positive (TP) detection, and number and rate of false-positive (FP) recalls (FPR). We estimated incremental cancer detection rate (CDR) from integrating 3D-mammography in screen-reading. RESULTS: Across all radiologists, TP detection (relative sensitivity) ranged between: 46% and 100% (median 59.5%) for 2D-mammography; 75% and 100% (median 76%) for integrated 2D/3D-mammography screening; 56% and 76% (median 64%) for 2Dsynthetic; 67% and 88% (median 78%) for 2Dsynthetic/3D-mammography. Integrating 3D-mammography led to incremental CDRs between 0/1000 and 3.5/1000 screens. FPR ranged between: 1.2% and 2.7% (median 2.25%) for 2D-mammography; 1.5% and 3.4% (median 2.75%) for 2D/3D-mammography; 1.6% and 4.6% (median 2.4%) for 2Dsynthetic; and 1.8% and 6.7% (median 3.0%) for 2Dsynthetic/3D-mammography. CONCLUSIONS: There was variability in the magnitude of effect from integrating 3D-mammography (relative to screen-reading with acquired or synthesised 2D-mammography alone) on individual radiologist's TP and FP detection, although there was an overall pattern of increasing cancer detection and also increasing FP recall for most readers.


Subject(s)
Breast Neoplasms/diagnostic imaging , Early Detection of Cancer , Mammography , Radiographic Image Interpretation, Computer-Assisted , Aged , Breast Neoplasms/pathology , False Positive Reactions , Female , Humans , Imaging, Three-Dimensional , Mass Screening , Middle Aged , Prospective Studies , Radiologists , Sensitivity and Specificity
2.
Cancer Epidemiol ; 47: 94-99, 2017 04.
Article in English | MEDLINE | ID: mdl-28192742

ABSTRACT

BACKGROUND: Most population breast cancer (BC) screening programs use double-reading of 2D-mammography. We recently reported the screening with tomosynthesis or standard mammography-2 (STORM-2) trial, showing that double-read tomosynthesis (pseudo-3D-mammography) detected more BC than double-read 2D-mammography. In this study, we compare screen-detection measures for single-reading of 3D-mammography with those for double-reading of 2D-mammography, to inform screening practice. METHODS: This is a secondary analysis based on STORM-2 which prospectively compared 3D-mammography and 2D-mammography in sequential screen-readings. Asymptomatic women ≥49 years who attended population-based screening (Trento, 2013-2015) were recruited. Participants recalled at any screen-read from parallel double-reading arms underwent further testing and/or biopsy. Single-reading of 3D-mammography, integrated with acquired or synthetized 2D-mammograms, was compared to double-reading of 2D-mammograhy alone for screen-detection measures: number of detected BCs, cancer detection rate (CDR), number and percentage of false-positive recall (FPR). Paired binary data were compared using McNemar's test. RESULTS: Screening detected 90, including 74 invasive, BCs in 85 of 9672 participants. CDRs for single-reading using integrated 2D/3D-mammography (8.2 per 1000 screens; 95% CI 6.5-10.2) or 2D synthetic/3D-mammography (8.4 per 1000 screens; 95% CI: 6.7-10.4) were significantly higher than CDR for double-reading of 2D-mammography (6.3 per 1000 screens; 95% CI: 4.8-8.1), P<0.001 both comparisons. FPR% for single-read 2D/3D-mammography (2.60%; 95% CI: 2.29-2.94), or single-read 2D synthetic/3D-mammography (2.76%; 95% CI: 2.45-3.11), were significantly lower than FPR% for double-read 2D-mammography (3.42%; 95% CI: 3.07-3.80), P<0.001 and P=0.002 respectively. CONCLUSIONS: Single-reading of 3D-mammography (integrated 2D/3D or 2Dsynthetic/3D) detected more BC, and had lower FPR, compared to current practice of double-reading 2D-mammography alone - these findings have implications for population BC screening programs.


Subject(s)
Breast Neoplasms/diagnostic imaging , Early Detection of Cancer/standards , Imaging, Three-Dimensional/standards , Mammography/standards , Tomography, X-Ray Computed/methods , Breast Neoplasms/epidemiology , Breast Neoplasms/pathology , Clinical Trials as Topic , Early Detection of Cancer/methods , Female , Humans , Imaging, Three-Dimensional/methods , Italy/epidemiology , Mammography/methods , Middle Aged , Prospective Studies , Radiographic Image Interpretation, Computer-Assisted/methods
3.
Lancet Oncol ; 17(8): 1105-1113, 2016 08.
Article in English | MEDLINE | ID: mdl-27345635

ABSTRACT

BACKGROUND: Breast tomosynthesis (pseudo-3D mammography) improves breast cancer detection when added to 2D mammography. In this study, we examined whether integrating 3D mammography with either standard 2D mammography acquisitions or with synthetic 2D images (reconstructed from 3D mammography) would detect more cases of breast cancer than 2D mammography alone, to potentially reduce the radiation burden from the combination of 2D plus 3D acquisitions. METHODS: The Screening with Tomosynthesis Or standard Mammography-2 (STORM-2) study was a prospective population-based screening study comparing integrated 3D mammography (dual-acquisition 2D-3D mammography or 2D synthetic-3D mammography) with 2D mammography alone. Asymptomatic women aged 49 years or older who attended population-based screening in Trento, Italy were recruited for the study. All participants underwent digital mammography with 2D and 3D mammography acquisitions, with the use of software that allowed synthetic 2D mammographic images to be reconstructed from 3D acquisitions. Mammography screen-reading was done in two parallel double-readings conducted sequentially for 2D acquisitions followed by integrated acquisitions. Recall based on a positive mammography result was defined as recall at any screen read. Primary outcome measures were a comparison between integrated (2D-3D or 2D synthetic-3D) mammography and 2D mammography alone of the number of cases of screen-detected breast cancer, the cancer detection rate per 1000 screens, the incremental cancer detection rate, and the number and percentage of false-positive recalls. FINDINGS: Between May 31, 2013, and May 29, 2015, 10 255 women were invited to participate, of whom 9672 agreed to participate and were screened. In these 9672 participants (median age 58 years [IQR 53-63]), screening detected 90 cases of breast cancer, including 74 invasive breast cancers, in 85 women (five women had bilateral breast cancer). To account for these bilateral cancers in cancer detection rate estimates, the number of screens used for analysis was 9677. Both 2D-3D mammography (cancer detection rate 8·5 per 1000 screens [82 cancers detected in 9677 screens]; 95% CI 6·7-10·5) and 2D synthetic-3D mammography (8·8 per 1000 [85 in 9677]; 7·0-10·8) had significantly higher rates of breast cancer detection than 2D mammography alone (6·3 per 1000 [61 in 9677], 4·8-8·1; p<0·0001 for both comparisons). The cancer detection rate did not differ significantly between 2D-3D mammography and 2D synthetic-3D mammography (p=0·58). Compared with 2D mammography alone, the incremental cancer detection rate from 2D-3D mammography was 2·2 per 1000 screens (95% CI 1·2-3·3) and that from 2D synthetic-3D mammography was 2·5 per 1000 (1·4-3·8). Compared with the proportion of false-positive recalls from 2D mammography alone (328 of 9587 participants not found to have cancer at assessment) [3·42%; 95% CI 3·07-3·80]), false-positive recall was significantly higher for 2D-3D mammography (381 of 9587 [3·97%; 3·59-4·38], p=0·00063) and for 2D synthetic-3D mammography (427 of 9587 [4·45%; 4·05-4·89], p<0·0001). INTERPRETATION: Integration of 3D mammography (2D-3D or 2D synthetic-3D) detected more cases of breast cancer than 2D mammography alone, but increased the percentage of false-positive recalls in sequential screen-reading. These results should be considered in the context of the trade-off between benefits and harms inherent in population breast cancer screening, including that significantly increased breast cancer detection from integrating 3D mammography into screening has the potential to augment screening benefit and also possibly contribute to overdiagnosis. FUNDING: None.


Subject(s)
Breast Neoplasms/diagnostic imaging , Carcinoma, Ductal, Breast/diagnostic imaging , Carcinoma, Intraductal, Noninfiltrating/diagnostic imaging , Carcinoma, Lobular/diagnostic imaging , Early Detection of Cancer/standards , Mammography/standards , Tomography, X-Ray Computed/methods , Breast Neoplasms/epidemiology , Breast Neoplasms/pathology , Carcinoma, Ductal, Breast/epidemiology , Carcinoma, Ductal, Breast/secondary , Carcinoma, Intraductal, Noninfiltrating/epidemiology , Carcinoma, Intraductal, Noninfiltrating/pathology , Carcinoma, Lobular/epidemiology , Carcinoma, Lobular/secondary , Female , Follow-Up Studies , Humans , Italy/epidemiology , Lymphatic Metastasis , Middle Aged , Neoplasm Grading , Neoplasm Invasiveness , Neoplasm Staging , Prognosis , Prospective Studies , Radiographic Image Interpretation, Computer-Assisted/methods
SELECTION OF CITATIONS
SEARCH DETAIL