ABSTRACT
Cardiotoxicity, characterized by adverse impacts on normal heart function due to drug exposure, is a significant concern due to the potentially serious side effects associated with various pharmaceuticals. It is essential to detect the cardiotoxicity of a drug as early as possible in the testing phase of a medical composite. Therefore, there is a pressing need for more reliable in vitro models that accurately mimic the in vivo conditions of cardiac biopsies. In a functional beating heart, cardiac muscle cells are under the effect of static and cyclic stretches. It has been demonstrated that cultured cardiac biopsies can benefit from external mechanical loads that resemble the in vivo condition, increasing the probability of cardiotoxicity detection in the early testing stages. In this work, a biosensor is designed and fabricated to allow for stretch monitoring in biopsies and tissue cultures using an innovative sensing mechanism. The detection setup is based on a biocompatible, thin, flexible membrane-where the samples are attached-which is used as an optical waveguide to detect pressure-caused shape changes and stretches. Various prototypes have been fabricated with a cost-effective process, and different measurements have been carried out to experimentally validate the proposed measurement technique. From these evaluations, stretches of up to 1.5% have been measured, but the performed simulations point towards the possibility of expanding the considered technique up to 10-30% stretches.
Subject(s)
Cardiotoxicity , Heart , HumansABSTRACT
Cardiovascular diseases cause a high number of deaths nowadays. To improve these statistics, new strategies to better understand the electrical and mechanical abnormalities underlying them are urgently required. This study focuses on the development of a sensor to measure tissue stretch in excised tissues, enabling improved knowledge of biomechanical properties and allowing greater control in real time. A system made of biocompatible materials is described, which is based on two cantilevered platforms that integrate an optical fiber inside them to quantify the amount of stretch the tissues are exposed to with a precision of µm. The operating principle of the sensor is based on the variation of the optical path with the movement of the platforms onto which the samples are fixed. The conducted tests highlight that this system, based on a simple topology and technology, is capable of achieving the desired purpose (a resolution of â¼1 µm), enabling the tissue to be bathed in any medium within the system.