Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Medicina (B Aires) ; 77(1): 31-36, 2017.
Article in Spanish | MEDLINE | ID: mdl-28140308

ABSTRACT

Dabigatran etexilate (direct thrombin inhibitor) is effective in preventing embolic stroke in patients with atrial fibrillation. It does not require laboratory control, but given the high renal elimination, its measurement in plasma is important in renal failure. The objectives of the study were to verify the analytical quality of the diluted thrombin time assay for measurement of dabigatran plasma concentration (cc), correlate cc with classic coagulation assays, prothrombin time (PT) and activated partial thromboplastin time (APTT), and evaluate them according to the creatinine clearance (CLCr). Forty plasma samples of patients (34 consecutive and 6 suspected of drug accumulation) receiving dabigatran at 150 (n = 19) or 110 (n = 21) mg/12 hours were collected. Blood samples were drawn at 10-14 hours of the last intake. Dabigatran concentration was determined by diluted thrombin time (HemosIl DTI, Instrumentation Laboratory (IL). PT and APTT (IL) were performed on two fotooptical coagulometers, ACL TOP 300 and 500 (IL). DTI presented intra-assay coefficient of variation < 5.4% and inter-assay < 6%, linearity range 0-493 ng/ml. Patients' cc: median 83 (4-945) ng/ml. Individuals with CLCr in the lowest tertile (22.6-46.1 ml/min) showed significantly higher median cc: 308 (49-945), compared to the average 72 (12-190) and highest tertile, 60 (4-118) ng/ml. Correlation between cc and APTT or PT were moderate, r2 = 0.59 and -0.66, p < 0.0001, respectively. DTI test allowed us to quantify plasma dabigatran levels, both in patients with normal or altered renal function, representing a useful tool in clinical situations such as renal failure, pre surgery or emergencies.


Subject(s)
Antithrombins/blood , Creatinine/blood , Dabigatran/blood , Adult , Aged , Aged, 80 and over , Drug Monitoring , Female , Humans , Kidney Function Tests , Male , Middle Aged , Partial Thromboplastin Time , Renal Insufficiency/blood , Thrombin Time , Young Adult
2.
Medicina (B.Aires) ; 77(1): 31-36, feb. 2017. graf, tab
Article in Spanish | LILACS | ID: biblio-841629

ABSTRACT

El dabigatrán etexilato (inhibidor directo de trombina) es eficaz en la prevención tromboembólica en pacientes con fibrilación auricular. No requiere control rutinario de laboratorio, pero dada su eliminación renal, sería importante medirlo ante el deterioro de la función renal. Los objetivos del trabajo fueron verificar la calidad analítica del ensayo tiempo de trombina diluido para medición de la concentración plasmática (cc) de dabigatrán, correlacionar las cc con las pruebas básicas de coagulación tiempo de protrombina (TP) y tiempo de tromboplastina parcial activada (APTT) y evaluarlas de acuerdo al clearance de creatinina (CLCr). Se utilizaron muestras de plasma de 40 pacientes que recibían dabigatrán 150 (n = 19) o 110 (n = 21) mg/12 horas, colectadas 10-14 horas después de la última toma. Los ensayos de trombina diluida HemosIL DTI para la medición de dabigatrán, TP y APTT (IL), fueron realizados en coagulómetros fotoópticos ACL TOP 300 y 500 (IL). El DTI presentó coeficiente de variación intraensayo < 5.4% e interensayo < 6.0%, rango de linealidad 0-493 ng/ml; cc medidas en pacientes: mediana 83 (4-945) ng/ml. Individuos con CLCr en tercil inferior (< 46.1 ml/min) presentaron cc significativamente más elevadas, 308 (49-945), que los de tercilos medio, 72 (12-190), y superior, 60 (4-118) ng/ml. Las correlaciones cc vs. APTT o TP fueron moderadas, r2 = 0.59, -0.66, p < 0.0001, respectivamente. La prueba ensayada permitió cuantificar el nivel de dabigatrán plasmático tanto en pacientes con función renal normal como deteriorada, representando una herramienta útil en situaciones clínicas como deterioro de la función renal, pre cirugía o emergencias.


Dabigatran etexilate (direct thrombin inhibitor) is effective in preventing embolic stroke in patients with atrial fibrillation. It does not require laboratory control, but given the high renal elimination, its measurement in plasma is important in renal failure. The objectives of the study were to verify the analytical quality of the diluted thrombin time assay for measurement of dabigatran plasma concentration (cc), correlate cc with classic coagulation assays, prothrombin time (PT) and activated partial thromboplastin time (APTT), and evaluate them according to the creatinine clearance (CLCr). Forty plasma samples of patients (34 consecutive and 6 suspected of drug accumulation) receiving dabigatran at 150 (n = 19) or 110 (n = 21) mg/12 hours were collected. Blood samples were drawn at 10-14 hours of the last intake. Dabigatran concentration was determined by diluted thrombin time (HemosIl DTI, Instrumentation Laboratory (IL). PT and APTT (IL) were performed on two fotooptical coagulometers, ACL TOP 300 and 500 (IL). DTI presented intra-assay coefficient of variation < 5.4% and inter-assay < 6%, linearity range 0-493 ng/ml. Patients´ cc: median 83 (4-945) ng/ml. Individuals with CLCr in the lowest tertile (22.6-46.1 ml/min) showed significantly higher median cc: 308 (49-945), compared to the average 72 (12-190) and highest tertile, 60 (4-118) ng/ml. Correlation between cc and APTT or PT were moderate, r2 = 0.59 and -0.66, p < 0.0001, respectively. DTI test allowed us to quantify plasma dabigatran levels, both in patients with normal or altered renal function, representing a useful tool in clinical situations such as renal failure, pre surgery or emergencies.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Antithrombins/blood , Creatinine/blood , Dabigatran/blood , Partial Thromboplastin Time , Thrombin Time , Drug Monitoring , Renal Insufficiency/blood , Kidney Function Tests
3.
Clin Lab ; 62(11): 2085-2089, 2016 Nov 01.
Article in English | MEDLINE | ID: mdl-28164666

ABSTRACT

BACKGROUND: Laboratory determination of fibrinogen/fibrin degradation product (FDP) levels is important as a hyperfibrinolytic state marker. The aim of the study was to verify the analytical performance of an automated immunoturbidimetric assay (AIMT) for FDP and its comparison to a latex agglutination semiquantitative (SLAT) test. METHODS: Total precision and accuracy was calculated following the EP 15-A2 protocol at two levels of controls. The protocol EP6 was performed for linearity. For semi-quantitative methods comparison, 71 consecutive samples were used. Concordance between methods results in term of positive and negative, and in categories, from <10 to > 160 µg/mL, was calculated through Cohen kappa coefficient (). RESULTS: Total CV%: low control (10.8 µg/mL) 8.0 and 3.7 vs. 4.8 and high control (31.3 µg/mL) 2.7 and 3.8 vs. 3.6, for coagulometer ACL TOP 500 and 300 vs. manufacturer claimed, respectively. Linearity between 0 and 125 µg/mL showed polynomial fit analysis applicable. When correlating AIMT to SLAT, a good concordance was observed:  of results expressed as positive-negative = 79.5% with 90.1% of agreement (p < 0.001), of results expressed as categories = 72.2% (p < 0.001) with 80.3% concordance. CONCLUSIONS: AIMT presented good analytical performance, and the concordance with SLAT by comparison of patients' samples results was also good. The implementation of IMMT in the clinical laboratory is suitable and reliable.


Subject(s)
Blood Coagulation Disorders/diagnosis , Fibrin Fibrinogen Degradation Products/analysis , Immunoturbidimetry , Latex Fixation Tests , Automation, Laboratory , Biomarkers/blood , Blood Coagulation , Blood Coagulation Disorders/blood , Case-Control Studies , Disseminated Intravascular Coagulation/blood , Disseminated Intravascular Coagulation/diagnosis , Humans , Linear Models , Predictive Value of Tests , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...