Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Chem Lab Med ; 61(8): 1511-1517, 2023 07 26.
Article in English | MEDLINE | ID: mdl-36799248

ABSTRACT

OBJECTIVES: To evaluate pre-analytical challenges related to high-volume central laboratory SARS-CoV-2 antigen testing with a prototype qualitative SARS-CoV-2 antigen immunoassay run on the automated Abbott ARCHITECT instrument. METHODS: Contrived positive and negative specimens and de-identified nasal and nasopharyngeal specimens in transport media were used to evaluate specimen and reagent on-board stability, assay analytical performance and interference, and clinical performance. RESULTS: TCID50/mL values were similar for specimens in various transport media. Inactivated positive clinical specimens and viral lysate (USA-WA1/2020) were positive on the prototype immunoassay. Within-laboratory imprecision was ≤0.10 SD (<1.00 S/C) with a ≤10% CV (≥1.00 S/C). Assay reagents were stable on board the instrument for 14 days. No high-dose hook effect was observed with a SARS-CoV-2 stock of Ct 13.0 (RLU>1.0 × 106). No interference was observed from mucin, whole blood, 12 drugs, and more than 20 cross-reactants. While specimen stability was limited at room temperature for specimens with or without viral inactivation, a single freeze/thaw cycle or long-term storage (>30 days) at -20 °C did not adversely impact specimen stability or assay performance. Specificity of the prototype SARS-CoV-2 antigen immunoassay was ≥98.5% and sensitivity was ≥89.5% across two ARCHITECT instruments. Assay sensitivity was inversely correlated with Ct and was similar to that reported for the Roche Elecsys® SARS-CoV-2 Ag immunoassay. CONCLUSIONS: The prototype SARS-CoV-2 antigen ARCHITECT immunoassay is sensitive and specific for detection of SARS-CoV-2 in nasal and nasopharyngeal specimens. Endogenous proteases in mucus may degrade the target antigen, which limits specimen storage and transport times and complicates assay workflow.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , Sensitivity and Specificity , COVID-19 Testing , Immunoassay
2.
J Virol Methods ; 264: 11-17, 2019 02.
Article in English | MEDLINE | ID: mdl-30381240

ABSTRACT

Hepatitis C Virus c33, a recombinant protein comprising residues 1192-1457 of NS3 helicase, has been a mainstay of HCV serology for decades. With seven unpaired cysteines, seroreactivity of E. coli expressed c33 is dependant on reductants. While engineering a c33 replacement for new anti-HCV serological tests, we sought to reduce oxidation sensitivity, a liability for immunodiagnostic reagent stability. A series of cysteine-to-serine substituted variants of a c33-like antigen was constructed and evaluated for reactivity against a panel of HCV-positive sera. Several variants were essentially nonreactive while others exhibited reactivity similar to or better than the wild-type construct. One demonstrated equivalent potency to wild-type but also diminished DTT dependence. To explore enhanced anti-NS3 reactivity, we constructed and examined an expanded series of antigens comprising individual helicase domains, the full-length helicase, additional cysteine-to-serine variants, and variants at positions critical to catalytic activity. Immunoassays using these latter NS3 helicase recombinants demonstrated that domain 1 possessed significantly more seroreactivity than previously believed, that the use of soluble full-length helicase protein enhanced sensitivity by several-fold over c33, and that anti-NS3 helicase seroreactivity was further enhanced by the introduction of point mutations which altered the catalytic activity or oxidation sensitivity of the antigen.


Subject(s)
DNA Helicases/genetics , DNA Helicases/immunology , Hepacivirus/enzymology , Hepacivirus/genetics , Serologic Tests , Viral Nonstructural Proteins/genetics , Antibodies, Viral/blood , Cysteine/genetics , Cysteine/immunology , DNA Helicases/metabolism , Escherichia coli/genetics , Genetic Engineering , Hepacivirus/immunology , Humans , Immunologic Tests , Point Mutation , Recombinant Proteins/genetics , Recombinant Proteins/immunology , Seroconversion , Viral Nonstructural Proteins/immunology
3.
J Clin Microbiol ; 56(8)2018 08.
Article in English | MEDLINE | ID: mdl-29743308

ABSTRACT

The tick-borne protozoan Babesia microti is responsible for more than 200 cases of transfusion-transmitted babesiosis (TTB) infection in the United States that have occurred over the last 30 years. Measures to mitigate the risk of TTB include nucleic acid testing (NAT) and B. microti antibody testing. A fully automated prototype B. microti antibody test was developed on the Architect instrument. The specificity was determined to be 99.98% in volunteer blood donors (n = 28,740) from areas considered to have low endemicity for B. microti The sensitivity of the prototype test was studied in experimentally infected macaques; a total of 128 samples were detected as positive whereas 125 were detected as positive with an indirect fluorescent antibody (IFA) test; additionally, 83 (89.2%) of the PCR-positive samples were detected in contrast to 81 (87.1%) using an IFA test. All PCR-positive samples that tested negative in the prototype antibody test were preseroconversion period samples. Following seroconversion, periods of intermittent parasitemia occurred; 17 PCR-negative samples drawn in between PCR-positive bleed dates tested positive both by the prototype test (robust reactivity) and IFA test (marginal reactivity) prior to the administration of therapeutic drugs, indicating that the PCR test failed to detect samples from persistently infected macaques. The prototype assay detected 56 of 58 (96.6%) human subjects diagnosed with clinical babesiosis by both PCR and IFA testing. Overall, the prototype anti-Babesia assay provides a highly sensitive and specific test for the diagnosis of B. microti infection. While PCR is preferred for detection of window-period parasitemia, antibody tests detect infected subjects during periods of low-level parasitemia.


Subject(s)
Antibodies, Protozoan/blood , Babesia microti/isolation & purification , Babesiosis/diagnosis , Immunoassay/standards , Parasitemia/diagnosis , Animals , Antibodies, Protozoan/immunology , Babesia microti/genetics , Babesia microti/immunology , Disease Models, Animal , Fluorescent Antibody Technique, Indirect/standards , Humans , Immunoassay/instrumentation , Immunoglobulin G/blood , Immunoglobulin M/blood , Macaca , Mass Screening , Polymerase Chain Reaction , Sensitivity and Specificity , Seroconversion , Transfusion Reaction/prevention & control
SELECTION OF CITATIONS
SEARCH DETAIL
...