Rev Sci Instrum ; 83(2): 02A910, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22380251

ABSTRACT

We investigated the ion-loss distribution on the sidewall of an electron cyclotron resonance (ECR) plasma chamber using the 18-GHz ECR charge breeder at the Tokai Radioactive Ion Accelerator Complex (TRIAC). Similarities and differences between the ion-loss distributions (longitudinal and azimuthal) of different ion species (i.e., radioactive (111)In(1+) and (140)Xe(1+) ions that are typical volatile and nonvolatile elements) was qualitatively discussed to understand the element dependence of the charge breeding efficiency. Especially, the similarities represent universal ion loss characteristics in an ECR charge breeder, which are different from the loss patterns of electrons on the ECRIS wall.

2.
Rev Sci Instrum ; 82(3): 033508, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21456738

ABSTRACT

The ion loss distribution in an electron cyclotron resonance ion source (ECRIS) was investigated to understand the element dependence of the charge breeding efficiency in an electron cyclotron resonance (ECR) charge breeder. The radioactive (111)In(1+) and (140)Xe(1+) ions (typical nonvolatile and volatile elements, respectively) were injected into the ECR charge breeder at the Tokai Radioactive Ion Accelerator Complex to breed their charge states. Their respective residual activities on the sidewall of the cylindrical plasma chamber of the source were measured after charge breeding as functions of the azimuthal angle and longitudinal position and two-dimensional distributions of ions lost during charge breeding in the ECRIS were obtained. These distributions had different azimuthal symmetries. The origins of these different azimuthal symmetries are qualitatively discussed by analyzing the differences and similarities in the observed wall-loss patterns. The implications for improving the charge breeding efficiencies of nonvolatile elements in ECR charge breeders are described. The similarities represent universal ion loss characteristics in an ECR charge breeder, which are different from the loss patterns of electrons on the ECRIS wall.

3.
Rev Sci Instrum ; 81(2): 02A902, 2010 Feb.
Article in English | MEDLINE | ID: mdl-20192400

ABSTRACT

We have developed a new ion source system in the isotope separator on-line at Japan Atomic Energy Agency, for separation of short-lived isotopes produced by proton-induced fission of (238)U. The ion source system is a forced electron beam induced arc discharge version E type ion source with a target container. We successfully operated this system at 2000 degrees C as a result of reductions in volume of the ion source and the target container, introduction of heating method by electron bombardment, and improvement to the heat shield. This new ion source system was tested using (238)U of 640 mg/cm(2) with a proton primary beam of 30 MeV, 350 nA. Release times were measured for Kr, In, and Xe. The values of release times are 2.6 s for Kr, 1.8 s for In, and 4.6 s for Xe. In this work, the ion source system enabled us to mass-separate short-lived isotopes such as (93)Kr(T(1/2)=1.286 s), (129)In(T(1/2)=0.61 s), and (141)Xe(T(1/2)=1.73 s) with intensity of 10(3) ions/s.

4.
Rev Sci Instrum ; 79(2 Pt 2): 02A906, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18315161

ABSTRACT

The KEKCB is an electron cyclotron resonance (ECR) ion source for converting singly charged ions to multicharged ones at Tokai Radioactive Ion Accelerator Complex. By using the KEKCB, singly charged gaseous and nongaseous ions were converted to multicharged ones of A/q approximately 7 with efficiencies of 7% and 2%, respectively. The conversion efficiency was found to be independent of the lifetime of the radioactive nuclei having lifetimes of the order of one second. Three collimators located at the entrance and the exit of the KEKCB defined the beam axis and facilitated beam injection. Grinding and washing the surfaces of aluminum electrode and plasma chamber dramatically reduced impurities originating from the ECR plasma of the KEKCB.