Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Cardiovasc Interv Ther ; 35(2): 194-202, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31292929

ABSTRACT

Studies on the outcomes of de novo three-vessel coronary artery disease (3VD) are limited. This study evaluated the outcomes after coronary revascularization in patients with 3VD treated by percutaneous coronary intervention (PCI) using second-generation drug-eluting stents (2ndDES) in comparison with coronary artery bypass grafting (CABG). We analyzed 853 patients undergoing either PCI or CABG for 3VD between 2010 and 2014. Of them, this study included 298 undergoing PCI with 2ndDES alone (PCI group) and 171 undergoing CABG (CABG group). The primary outcome measure was a composite of all-cause death, non-fatal myocardial infarction (MI), or stroke. The secondary outcome measures were cardiac death, MI, stroke, and target vessel revascularization (TVR). Propensity matching was used to adjust a cohort of patients with similar baseline characteristics. Between the PCI and CABG groups, no significant differences were found in the 3-year cumulative incidence of the primary outcome measure (14.9% vs. 12.9%, p = 0.60). After propensity score matching, no significant differences were found in the incidences of primary outcome measure (13.0% vs. 12.8%, p = 0.95), cardiac death, MI, and stroke (3.5% vs. 2.7%, p = 0.72; 1.2% vs. 0.0%, p = 0.31; and 4.9% vs. 3.1%, p = 0.35), whereas that of TVR was significantly higher in the PCI group (24.5 vs. 7.1%, p < 0.01). Compared with CABG, PCI with second-generation DES was not associated with higher risk of clinical outcomes, but was associated with a higher risk of TVR in the treatment of 3VD.


Subject(s)
Coronary Artery Bypass , Coronary Artery Disease/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention , Aged , Aged, 80 and over , Coronary Stenosis/therapy , Female , Follow-Up Studies , Humans , Male , Myocardial Infarction/epidemiology , Stroke/epidemiology
2.
Catheter Cardiovasc Interv ; 93(3): E120-E129, 2019 02 15.
Article in English | MEDLINE | ID: mdl-30345649

ABSTRACT

OBJECTIVES: The clinical implications of subintimal stenting (SS) of the recanalized chronic total occlusion (CTO) segment have not been characterized. We evaluated the in-hospital and the long-term clinical and angiographic outcomes of drug-eluting stents (DESs) deployed in true vs. false lumen of successfully recanalized CTO. METHODS AND RESULTS: Two independent reviewers analyzed the intravascular ultrasound (IVUS) images of 173 successfully recanalized CTO lesions (157 patients), between August 2011 and October 2012. After successful guidewire (GW) crossing, lesions were classified according to IVUS evaluation into two groups: (1) true lumen (TL) stenting group and (2) SS group; and compared with regards to in-hospital and long-term clinical outcomes. In 154 lesions, DESs were deployed in the TL; and in 19 (11%) lesions, DESs were deployed in the subintimal space (95% confidence interval: 6.3-15.6%). False GW tracking in the SS group resulted in increased rates of IVUS-detected dissection flaps (84% vs. 42.6%, P ≤ 0.001), intramural hematoma (32 vs. 11%, P = 0.01), and minor perforations 6/19 (31.6% vs. 8.4%, P = 0.002). At 1-year follow-up, both groups had similar cumulative rates of binary restenosis and target lesion revascularization (P = 0.73 and P = 0.97, respectively). Six patients (4.6%, 6/129 patients) in the TL group and none in the subintimal group died at 1 year. CONCLUSIONS: Acknowledging some limitations, our observations may suggest that, subintimal stent deployment in a recanalized CTO segments, using second generation DES and IVUS guidance, might have a comparable success rate and long-term angiographic and clinical outcomes as TL stenting.


Subject(s)
Coronary Angiography , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/therapy , Coronary Vessels/diagnostic imaging , Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Ultrasonography, Interventional , Aged , Chronic Disease , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/therapy , Databases, Factual , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Predictive Value of Tests , Registries , Retreatment , Retrospective Studies , Time Factors , Treatment Outcome
3.
EuroIntervention ; 14(11): e1183-e1191, 2018 Dec 07.
Article in English | MEDLINE | ID: mdl-30082257

ABSTRACT

AIMS: The aim of the study was to assess the long-term outcomes of coronary chronic total occlusion (CTO) lesions after retrograde percutaneous coronary intervention (PCI) in comparison with those after antegrade PCI alone. METHODS AND RESULTS: A total of 842 consecutive patients (928 CTO lesions) undergoing PCI and subsequent follow-up were classified into two groups: retrograde PCI for at least one CTO (n=302, retrograde group) and antegrade PCI alone (n=540, antegrade group). The total procedural success rate was 89.7%. The retrograde group had significantly higher incidences of periprocedural myocardial infarction and coronary perforation (7.3% vs. 3.7%, p=0.01; 7.9% vs. 4.4%, p=0.04, respectively). Median follow-up duration was 7.7 (interquartile range 5.6-8.7) years. Seven-year relative risk comparing the retrograde and antegrade groups was neutral in all-cause death (adjusted HR [aHR] 1.06, 95% CI: 0.75-1.49; p=0.745), cardiac death (aHR 0.85, 95% CI: 0.47-1.55; p=0.598), coronary artery bypass grafting (aHR 1.62, 95% CI: 0.74-3.54; p=0.229), and non-target vessel revascularisation (aHR 0.96, 95% CI: 0.78-1.17; p=0.663). CONCLUSIONS: Retrograde CTO PCI did not lead to worse long-term outcomes despite increased risk in periprocedural myocardial infarction and coronary perforation.


Subject(s)
Coronary Occlusion , Heart Injuries , Myocardial Infarction , Percutaneous Coronary Intervention , Chronic Disease , Coronary Angiography , Coronary Artery Bypass , Coronary Occlusion/surgery , Humans , Registries , Risk Factors , Treatment Outcome
4.
Circ J ; 82(11): 2820-2828, 2018 10 25.
Article in English | MEDLINE | ID: mdl-30158345

ABSTRACT

BACKGROUND: Little is known of the relationship between optical coherence tomography (OCT) findings and recurrent restenosis after paclitaxel-coated balloon (PCB) angioplasty for drug-eluting stent in-stent restenosis (DES-ISR). To identify the predictors of recurrent restenosis after PCB angioplasty, we investigated quantitative and qualitative OCT findings during PCB angioplasty for DES-ISR. Methods and Results: In all, 222 DES-ISR lesions treated by PCB angioplasty with OCT assessment and followed-up angiographically at 6 months were divided into restenotic and non-restenotic lesions on the basis of the presence or absence of restenosis at follow-up. There was a significantly higher proportion of the heterogeneous tissue pattern in restenotic than non-restenotic lesions (26.5% vs. 11.0%, respectively; P=0.02). The OCT-derived post-procedural minimal lumen and stent areas were significantly smaller in restenotic lesions, but the intima area was similar in both groups. Post-procedural stent underexpansion, defined as a stent diameter : size of the previous stent ratio <1.0, was more frequently observed in restenotic than non-restenotic lesions (33.3% vs. 17.4%, respectively; P=0.02). Multivariate analysis identified a heterogeneous tissue pattern (odds ratio [OR] 2.92; 95% confidence interval [CI] 1.32-6.47; P=0.006) and post-procedural stent underexpansion (OR 2.36; 95% CI 1.15-4.85; P=0.04) as independent predictors of recurrent restenosis. CONCLUSIONS: The heterogeneous tissue pattern and insufficient post-procedural minimal lumen area, caused primarily by stent underexpansion, may be associated with restenosis after PCB angioplasty for DES-ISR.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Angiography , Coronary Restenosis/diagnostic imaging , Drug-Eluting Stents , Graft Occlusion, Vascular/diagnostic imaging , Paclitaxel/administration & dosage , Aged , Aged, 80 and over , Female , Follow-Up Studies , Graft Occlusion, Vascular/etiology , Humans , Male , Middle Aged , Tomography, Optical Coherence
5.
Circ J ; 82(7): 1874-1883, 2018 06 25.
Article in English | MEDLINE | ID: mdl-29695656

ABSTRACT

BACKGROUND: Data on bleeding events in Japanese patients with acute coronary syndrome (ACS) are insufficient. In addition, the efficacy and safety of a maintenance dose of prasugrel 2.5 mg/day in high bleeding risk patients are unknown.Methods and Results:We prospectively enrolled 1,167 consecutive patients with suspected ACS and undergoing percutaneous coronary intervention. The maintenance dose of prasugrel 2.5 mg/day was prescribed for patients with a low body weight (≤50 kg), elderly (≥75 years), or renal insufficiency (eGFR ≤30 mL/min/1.73 m2). In-hospital events were assessed in 992 ACS patients treated with drug-eluting stents. Excluding 29 in-hospital deaths, out-of-hospital events were assessed in 963 ACS patients. The primary safety outcome measure was major bleeding (Bleeding Academic Research Consortium types 3 and 5). The incidence of in-hospital major bleeding was 3.4%. Multivariate analysis showed that being elderly, low body weight, renal insufficiency, stroke history, femoral approach, and mechanical support usage were independent predictors of in-hospital major bleeding. The cumulative 1-year incidence of out-of-hospital major bleeding was not significantly different between the prasugrel 2.5 mg/day (n=284) and 3.75 mg/day (n=487) groups (1.6% vs. 0.7%, log-rank P=0.24). That of out-of-hospital definite or probable stent thrombosis was 0% in both groups. CONCLUSIONS: The maintenance dose of adjusted prasugrel 2.5 mg/day seems to be one option in ACS patients at high bleeding risk.


Subject(s)
Acute Coronary Syndrome/complications , Hemorrhage/chemically induced , Prasugrel Hydrochloride/administration & dosage , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/drug therapy , Aged , Aged, 80 and over , Dose-Response Relationship, Drug , Female , Hemorrhage/prevention & control , Hospitalization , Humans , Japan , Male , Middle Aged , Platelet Aggregation Inhibitors/administration & dosage , Platelet Aggregation Inhibitors/adverse effects , Prasugrel Hydrochloride/adverse effects , Prognosis , Prospective Studies , Risk Factors , Stents/adverse effects , Thrombosis/etiology
6.
Cardiovasc Revasc Med ; 19(1 Pt B): 88-94, 2018.
Article in English | MEDLINE | ID: mdl-28778392

ABSTRACT

BACKGROUND: Very long-term angiographic results after sirolimus-eluting stent (SES) implantation have not been clarified. This study investigated serial angiographic results of early (<1year), late (1-5years), and very late (>5years) follow-up after SES implantation and the progression process to very late SES failure. METHODS: We analyzed 631 lesions undergoing serial coronary angiography at early, late, and very late follow-up after SES implantation. The results of 205 lesions undergoing very late target lesion revascularization (VL-TLR; TLR beyond 5years) for acute coronary syndrome (ACS; 83) and non-ACS (122) were evaluated in comparison with 426 non-TLR lesions as a control group. RESULTS: Non-TLR lesions showed no attenuated decline of minimum lumen diameter from postprocedure (2.51±0.47mm), early (2.37±0.58mm), late (2.22±0.60mm), up to very late (2.01±0.63mm) follow-up. In VL-TLR lesions, compared to non-TLR lesions, late lumen loss (LLL) from postprocedure to early follow-up was similar, but delayed LLL from early to late follow-up was significantly larger (0.25±0.48mm vs. 0.15±0.46mm, p=0.01). Although the delayed LLL was significantly larger in non-ACS lesions (0.29±0.44mm) than in non-TLR lesions (p<0.01), it was similar in ACS (0.19±0.52mm) and non-TLR lesions (p=0.54). Very delayed LLL from late to very late follow-up was 1.65±0.82mm in ACS lesions and 1.10±0.76mm in non-ACS lesions. CONCLUSIONS: Progression of in-stent luminal narrowing did not attenuate beyond 5years after SES implantation. In very late SES failure, stent-related ACS lesions showed gradual luminal narrowing and subsequent rapid progression beyond 5years, whereas non-ACS lesions had progressive luminal narrowing within 5years.


Subject(s)
Acute Coronary Syndrome/surgery , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/surgery , Coronary Restenosis/etiology , Coronary Vessels/surgery , Drug-Eluting Stents , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Prosthesis Failure , Sirolimus/administration & dosage , Acute Coronary Syndrome/diagnostic imaging , Aged , Aged, 80 and over , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Restenosis/diagnostic imaging , Coronary Vessels/diagnostic imaging , Female , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Time Factors , Treatment Outcome
7.
Circ J ; 82(3): 798-806, 2018 02 23.
Article in English | MEDLINE | ID: mdl-29269613

ABSTRACT

BACKGROUND: Data on outcomes of non-left main coronary bifurcation lesions treated with the 2-stent strategy using 2nd-generation drug-eluting stents (DES) are insufficient.Methods and Results:The 2-year outcomes and predictors of target lesion revascularization (TLR) in 356 patients with 364 non-left main coronary bifurcation lesions treated with the 2-stent strategy using 2nd-generation DES were retrospectively evaluated. The primary outcome measure was defined as TLR. The median follow-up duration was 3.6 years (interquartile range, 2.7-4.9 years). A 2-year clinical follow-up was achieved in 99.2%. The 2-year cumulative incidence of TLR was 9.2%. Multiple stents implanted in either the main branch (adjusted odds ratio [OR] 3.01; 95% confidence interval [CI]: 1.37-6.62; P=0.006) or the side branch (adjusted OR 4.55; 95% CI: 1.99-10.4; P<0.001) and the culprit in the left anterior descending artery and its diagonal branch (adjusted OR 0.33; 95% CI: 0.15-0.75: P=0.008) were independent predictors of TLR within 2 years. CONCLUSIONS: The 2-year outcomes for the 2-stent strategy using 2nd-generation DES in non-left main coronary bifurcation lesions were acceptable. Coronary bifurcation location in the left anterior descending artery and its diagonal branch is protective against TLR, whereas multiple stents implanted in either the main branch or the side branch was associated with TLR.


Subject(s)
Coronary Vessels/pathology , Drug-Eluting Stents , Myocardial Revascularization , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome
8.
Circ J ; 82(2): 469-476, 2018 01 25.
Article in English | MEDLINE | ID: mdl-28659551

ABSTRACT

BACKGROUND: Little is known about the impact of stent type on the prognosis of vasospastic angina (VSA) in patients who undergo stent implantation.Methods and Results:We evaluated consecutive patients undergoing coronary angiography with positive (n=650; VSA) and negative (n=2,872; non-VSA) ergonovine testing. Among them, 304 patients undergoing stent implantation for organic stenosis were classified for comparison into 3 respective VSA and non-VSA groups based on stent type (68 and 78 with bare-metal stent [BMS]; 21 and 49 with sirolimus-eluting stent [SES]; 26 and 62 with newer generation drug-eluting stent [N-DES]). The primary outcome was defined as target lesion revascularization, target vessel revascularization, emergency coronary angiography, and cardiac death. The 2-year cumulative incidence of the primary outcome was significantly higher in the VSA group than non-VSA group after SES implantation (38.1% vs. 16.1%, P=0.03), whereas there were no differences between the 2 groups after both BMS implantation and N-DES implantation. The difference in the percent diameter stenosis from mid-term to late-term follow-up was significantly higher in the VSA group than non-VSA group (10.0% vs. 2.3%, P=0.045) after SES implantation, whereas there were no differences between the 2 groups after both BMS implantation and N-DES implantation. CONCLUSIONS: The impact of VSA on clinical and angiographic outcomes was observed only in SES implantation, but not after N-DES or BMS implantation.


Subject(s)
Angina Pectoris/therapy , Coronary Stenosis/therapy , Coronary Vasospasm/therapy , Stents/standards , Aged , Angina Pectoris/diagnosis , Angina Pectoris/diagnostic imaging , Coronary Angiography , Coronary Stenosis/diagnosis , Coronary Stenosis/diagnostic imaging , Coronary Vasospasm/diagnosis , Coronary Vasospasm/diagnostic imaging , Drug-Eluting Stents , Female , Humans , Male , Middle Aged , Prognosis , Self Expandable Metallic Stents , Treatment Outcome
9.
Int Heart J ; 58(6): 868-873, 2017 Dec 12.
Article in English | MEDLINE | ID: mdl-29151487

ABSTRACT

A relationship between serum polyunsaturated fatty acids (PUFAs) and cardiovascular disease has been reported; however, the existence of a relationship between serum PUFAs and extent of vessel disease (VD) in patients with ST elevation myocardial infarction (STEMI) remains unclear.Between July 2011 and June 2015, 866 consecutive STEMI patients underwent emergent percutaneous coronary intervention, 507 of whom were enrolled and classified into three groups according to the initial angiograms: 1VD, 294 patients; 2VD, 110 patients; and 3VD/left main trunk disease (LMTD), 103 patients. Serum levels of PUFAs, including eicosapentaenoic acid (EPA), docosahexaenoic acid (DHA), and arachidonic acid, and other laboratory data during hospitalization were evaluated.The serum EPA level in the 3VD/LMTD group was significantly lower than that in the 1VD group (55.5 ± 22.1 versus 66.2 ± 28.7, P = 0.002) and was slightly lower than that in the 2VD group (55.5 ± 22.1 versus 65.2 ± 28.9, P = 0.0167). Multivariate adjustment analysis revealed that age ≥ 70 years (odds ratio, 1.72; 95% confidence interval, 1.03-2.89; P = 0.038) and a low serum EPA level (odds ratio, 0.98; 95% confidence interval, 0.99-1.00; P = 0.023) were independent risk factors for 3VD/LMTD, while a low serum DHA level was not.A low serum EPA level may be more strongly related than a low serum DHA level to the extent of VD in STEMI patients. Age ≥ 70 years and a low serum EPA level may be independent risk factors for 3VD/LMTD.


Subject(s)
Coronary Artery Disease/blood , Coronary Vessels/diagnostic imaging , Fatty Acids, Omega-3/blood , ST Elevation Myocardial Infarction/blood , Aged , Aged, 80 and over , Biomarkers/blood , Coronary Angiography , Coronary Artery Disease/complications , Coronary Artery Disease/diagnostic imaging , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction/complications , ST Elevation Myocardial Infarction/therapy
10.
Circ J ; 82(1): 211-217, 2017 12 25.
Article in English | MEDLINE | ID: mdl-28855451

ABSTRACT

BACKGROUND: Stent fracture (SF) and peri-stent contrast staining (PSS) after sirolimus-eluting stent (SES) implantation are considered to be related to very late stent thrombosis (VLST). How dual antiplatelet therapy (DAPT) beyond 1 year affects the clinical outcomes of patients with SF or PSS remains unclear.Methods and Results:Based on their DAPT status, 1,962 patients undergoing SES implantation were classified as on-thienopyridine (n=1,404) or off-thienopyridine (n=558). The 6-year incidence of VLST was significantly lower in the on-thienopyridine patients (0.56% vs. 1.8%, P=0.01), whereas cardiac death and myocardial infarction (MI) were similar (5.0% vs. 6.2%, P=0.31; 3.2% vs. 4.0%, P=0.33; respectively). The 1,962 patients were also classified as having SF/PSS (n=256) or non-SF/PSS (n=1,706). In the SF/PSS group, VLST and MI were significantly lower in on-thienopyridine patients (1.9% vs. 10.1%, P=0.003; 3.5% vs. 10.3%, P=0.02; respectively). In the non-SF/PSS group, VLST and MI were similar (0.36% vs. 0.45%, P=0.78; 3.2% vs. 3.0%, P=0.93; respectively). In both groups, cardiac death was similar (3.6% vs. 4.3%, P=0.78; 5.2% vs. 6.5%, P=0.32; respectively). CONCLUSIONS: Prolonged DAPT was associated with significantly lower incidences of VLST and MI in the SF/PSS group, but had no effect on cardiac death, VLST, or MI in the non-SF/PSS group.


Subject(s)
Drug-Eluting Stents/adverse effects , Platelet Aggregation Inhibitors/therapeutic use , Pyridines/therapeutic use , Sirolimus/administration & dosage , Aged , Aspirin/therapeutic use , Death , Female , Humans , Male , Middle Aged , Myocardial Infarction/etiology , Prosthesis Implantation , Retrospective Studies , Staining and Labeling , Thrombosis/drug therapy , Thrombosis/etiology , Time Factors , Treatment Outcome
11.
J Interv Cardiol ; 30(6): 550-557, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28940552

ABSTRACT

BACKGROUND: Prior reports have suggested that the design of the Promus Element stent is prone to longitudinal stent deformation (LSD). However, little is known about the clinical and angiographic outcomes of Promus Element stent axial deformations when implanted in unrestricted coronary lesions. METHOD AND RESULTS: Two independent reviewers retrospectively evaluated the procedure steps of 961 Promus Element stent (833 de novo lesions in 494 consecutive patients) implanted in unrestricted coronary lesions, between February 2012 and March 2013, and compared the prevalence, predictors, and the mid-term clinical and angiographic outcomes between lesions with and without stent deformation. Fifteen stents (1.56%) with LSD were observed (95% confidence interval [CI]: 0.78-2.34%). The proximal edge of the stent was deformed in 13 stents (86.6%). Ostial stenting (Adjusted Odds ratio [OR]: 9; 95%CI: 2.27-33.3; P = 0.002), and bifurcation lesions (Adjusted OR: 3; 95%CI: 1.03-8.8; P = 0.04) were independently associated with the occurrence of stent deformation. LSD led to unplanned stenting in (53%, 8 of 15) of the deformed stents, which consumed larger contrast volume and longer fluoroscopy time. At 8-month follow-up, there was no significant difference in binary restenosis rate and target lesions revascularization between both groups (P = 0.98, and P = 0.56, respectively), while death occurred in six patients of the non-LSD group (1.36%, 6 of 440) and none in the LSD group. All patients of the LSD group had no major adverse clinical events at 8-month follow-up. CONCLUSIONS: Axial stent deformation in Promus Element platform is an infrequent event, occurs following manipulation of the interventional tools. Other than unplanned stenting, the LSD was not associated with any adverse clinical events at 8-month follow-up.


Subject(s)
Coronary Angiography , Drug-Eluting Stents/adverse effects , Percutaneous Coronary Intervention , Aged , Coronary Artery Disease/therapy , Coronary Restenosis/diagnostic imaging , Female , Humans , Male , Retrospective Studies
12.
Circ J ; 81(10): 1514-1521, 2017 Sep 25.
Article in English | MEDLINE | ID: mdl-28626202

ABSTRACT

BACKGROUND: Stent fracture (SF) and peri-stent contrast staining (PSS) after sirolimus-eluting stent implantation are reported to be risk factors of adverse events. However, the effect of these after everolimus-eluting stent (EES) implantation on long-term outcomes remains unclear.Methods and Results:The study sample comprised 636 patients (1,081 lesions) undergoing EES implantation in 2010 and follow-up angiography within 1 year. The 5-year cumulative rates of target lesion revascularization (TLR) and major adverse cardiac events (MACE: a combination of all-cause death, myocardial infarction, and TLR) were compared between patients with and without SF or PSS. SF was observed in 2.7%, and PSS in 3.0%. The cumulative rates of MACE and TLR were significantly higher in the SF group than in the non-SF group (51.7% vs. 27.5% and 48.3% vs. 13.4%, respectively), but showed no significant differences between the PSS and non-PSS groups. In a landmark analysis, the rate of TLR within 1 year was significantly higher in the SF group than in the non-SF group (44.8% vs. 7.2%), but beyond 1 year showed no significant difference (6.3% vs 6.7%). CONCLUSIONS: The 5-year clinical outcomes suggested that SF after EES implantation is related to increased risk of MACE and TLR, especially within 1 year after the procedure, but PSS after EES implantation is unrelated.


Subject(s)
Drug-Eluting Stents/adverse effects , Everolimus/administration & dosage , Aged , Female , Humans , Male , Middle Aged , Myocardial Infarction , Myocardial Revascularization , Prosthesis Failure , Prosthesis Implantation/adverse effects , Staining and Labeling , Treatment Outcome
13.
Int J Cardiol ; 243: 116-120, 2017 Sep 15.
Article in English | MEDLINE | ID: mdl-28545849

ABSTRACT

BACKGROUNDS: The difference in clinical presentations (acute coronary syndrome [ACS] and stable coronary artery disease [SCAD]) and related angiographic morphologies of sirolimus-eluting stent (SES) failure requiring target lesion revascularization (TLR) during early-term (<1year), late-term (1-5years), and very late-term periods (>5years) remains unknown. METHODS: Among 4484 lesions undergoing SES implantation, clinically-driven TLR was performed on 105 lesions during early-term, 169 lesions during late-term, and 147 lesions during very late-term period. Angiographic morphological patterns were divided into focal or non-focal patterns and stent-edge or stent-body patterns. RESULTS: The proportion of ACS substantially increased in very late TLR lesions (57.1%) from early (40.0%, p=0.01) and late TLR lesions (36.7%, p<0.001). The proportions of both stent-edge and non-focal patterns were higher in very late TLR lesions than in early and late TLR lesions. Although the stent-edge pattern tended to be more prevalent in SCAD lesions than in ACS lesions during the early- and late-term periods, it was more frequently observed in ACS lesions than in SCAD lesions during the very late-term period (65.5% vs. 47.6%, p=0.04). The non-focal pattern was more frequent in ACS lesions than in SCAD lesions during all 3 periods. However, the proportion of the non-focal pattern in ACS lesions was extremely high during the very late-term (90.5%) compared with the early- (47.6%, p<0.001) and late-term periods (48.4%, p<0.001). CONCLUSIONS: Stent-related ACS became more common beyond 5years after SES implantation. Stent-edge and non-focal patterns were the main angiographic morphologies of very late SES failure, particularly causing ACS.


Subject(s)
Acute Coronary Syndrome/diagnostic imaging , Coronary Angiography/trends , Coronary Artery Disease/diagnostic imaging , Drug-Eluting Stents/trends , Percutaneous Coronary Intervention/trends , Prosthesis Failure/trends , Acute Coronary Syndrome/surgery , Coronary Artery Disease/surgery , Drug-Eluting Stents/adverse effects , Follow-Up Studies , Humans , Percutaneous Coronary Intervention/instrumentation , Retrospective Studies , Sirolimus/administration & dosage , Time Factors , Treatment Outcome
14.
Heart ; 103(13): 1002-1008, 2017 07.
Article in English | MEDLINE | ID: mdl-28096181

ABSTRACT

OBJECTIVE: Efficacy and safety data on biodegradable polymer-coated biolimus-eluting stent (BP-BES) are currently limited to 5 years. We evaluated longer term (8-10 years) clinical and angiographic outcomes after BP-BES implantation. METHODS: Between 2005 and 2008, 243 patients (301 lesions) underwent BP-BES implantation. The primary clinical outcome measure was defined as any target lesion revascularisation (TLR). Absolute serial angiographic studies without any concomitant TLR within 2 years after the procedure were performed in 55 patients (65 lesions) at postprocedure, mid-term (within 1 year), late term (between 1 and 2 years) and very late term (beyond 2 years). RESULTS: The median follow-up duration was 9.4 years (IQR 8.2-10.2 years). The 8-year cumulative incidence of any TLR was 20.3%. The increase rate was approximately 7% per year in the first 2 years, but decelerated to approximately 1.2% per year beyond 2 years after the procedure. The minimal lumen diameter significantly decreased from postprocedure (2.63±0.44 mm) to mid-term (2.43±0.59 mm, p=0.002) and from late term (2.27±0.63 mm) to very late term (1.98±0.73 mm, p=0.002). The 8-year cumulative incidences of definite or probable stent thrombosis (ST) and major bleeding (Bleeding Academic Research Consortium (BARC) ≥3) were 0.5% and 12.0%, respectively. Definite ST was none within 10 years in the entire cohort. CONCLUSIONS: The long-term clinical outcomes after BP-BES implantation were favourable, although angiographic late progression of luminal narrowing did not reach a plateau. The incidence of ST remained notably low, whereas that of major bleeding gradually increased.


Subject(s)
Absorbable Implants , Coated Materials, Biocompatible , Coronary Artery Disease/surgery , Drug-Eluting Stents , Forecasting , Polymers , Sirolimus/analogs & derivatives , Aged , Coronary Angiography , Coronary Artery Disease/diagnosis , Female , Follow-Up Studies , Humans , Immunosuppressive Agents/pharmacology , Male , Myocardial Revascularization/methods , Prosthesis Design , Retrospective Studies , Sirolimus/pharmacology , Treatment Outcome
15.
Am J Cardiol ; 119(3): 365-371, 2017 Feb 01.
Article in English | MEDLINE | ID: mdl-27894569

ABSTRACT

The long-term outcomes of patients who underwent paclitaxel-coated balloon (PCB) angioplasty for drug-eluting stent restenosis (DES-ISR) remain unclear. We investigated the 5-year safety and efficacy outcomes of PCB angioplasty for DES-ISR. The study included 185 patients with 216 DES-ISR lesions who underwent PCB angioplasty from September 2008 to December 2010. Two serial angiographic follow-ups were routinely scheduled at 6 and 18 months after the index procedure. Five-year clinical outcomes were investigated. The mean duration of follow-up was 2,052 ± 352.5 days, and 94.1% of the patients completed the 5-year follow-up. Recurrent restenosis was observed in 48 lesions (22.2%) at the 6-month follow-up and late restenosis was observed in 22 lesions (14.3%) at the 18-month follow-up. Very late restenosis was observed in 6 lesions (6.8%), and target lesion revascularization (TLR) was performed for 8 lesions (13.6%) beyond 24 months after the procedure. The cumulative rates of TLR at 1, 2, and 5 years were 16.4%, 28.9%, and 34.1%, respectively. In patients who underwent TLR, 87% (52 of 60 patients) underwent TLR within the first 2 years after the index procedure. Multivariable analysis revealed that in-stent occlusion lesion (odds ratio [OR] 2.21; 95% confidence interval [CI] 1.09 to 4.47; p = 0.03), postprocedural percent diameter stenosis >35% (OR 3.19; 95% CI 1.54 to 6.68; p = 0.001), and right coronary artery ostial lesions (OR 5.56; 95% CI 1.40 to 24.9; p = 0.01) were independent predictors of recurrent restenosis. In conclusion, our results suggest that long-term outcomes after PCB angioplasty are acceptable; however, close follow-up during the first 2 years following this procedure may be necessary.


Subject(s)
Angioplasty, Balloon, Coronary/methods , Antineoplastic Agents, Phytogenic/administration & dosage , Coronary Restenosis/therapy , Drug-Eluting Stents , Graft Occlusion, Vascular/therapy , Paclitaxel/administration & dosage , Aged , Cause of Death , Coronary Angiography , Coronary Restenosis/diagnostic imaging , Female , Follow-Up Studies , Graft Occlusion, Vascular/diagnostic imaging , Humans , Male , Middle Aged , Mortality , Myocardial Infarction/epidemiology , Myocardial Revascularization/statistics & numerical data , Retrospective Studies , Treatment Outcome
16.
Circ Cardiovasc Interv ; 9(12)2016 12.
Article in English | MEDLINE | ID: mdl-27932532

ABSTRACT

BACKGROUND: There are currently inadequate data about whether late restenosis occurs after drug-eluting stent (DES) implantation in patients with DES restenosis. METHODS AND RESULTS: We collected data for 608 patients who received revascularization for DES restenosis between 2004 and 2012 and analyzed 688 lesions: 359 lesions treated with a first-generation DES (first DES) and 329 lesions treated with a second-generation DES (second DES). Two serial angiographic follow-ups were routinely planned for the patients (at 8 and 20 months after the procedure). Early follow-up angiography was performed for 620 lesions (90.1%), and recurrent restenosis occurred in 84 lesions (25.8%) in the first DES group and in 72 lesions (24.5%) in the second DES group (P=0.78). Target lesion revascularization was performed for 69 lesions (21.2%) in the first DES group and for 48 lesions (16.3%) in the second DES group (P=0.15). Late follow-up angiography was performed for 438 (87.1%) of the remaining 503 lesions (excluding target lesion revascularization lesions), and late restenosis was found in 35 lesions (15.8%) in the first DES group and in 28 lesions (14.7%) in the second DES group (P=0.79). Nonfocal-type restenosis, percentage diameter stenosis after the procedure, previous stent size ≤2.5 mm, and right coronary artery ostial lesion were independent predictors of early restenosis. Nonfocal-type restenosis, percentage diameter stenosis at early follow-up, and stent fracture were independent predictors of late restenosis. CONCLUSIONS: Late restenosis occurs after both first DES implantation and second DES implantation for DES restenosis.


Subject(s)
Coronary Artery Disease/therapy , Coronary Restenosis/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Aged , Aged, 80 and over , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/physiopathology , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/physiopathology , Female , Humans , Male , Middle Aged , Prosthesis Design , Recurrence , Retrospective Studies , Risk Factors , Severity of Illness Index , Time Factors , Treatment Outcome
17.
Am Heart J ; 175: 47-55, 2016 05.
Article in English | MEDLINE | ID: mdl-27179723

ABSTRACT

UNLABELLED: Little is known about the long-term outcomes after first-generation sirolimus-eluting stent (SES) implantation. We aimed to investigate the clinical outcomes up to 10 years after SES implantation. METHODS: The study population comprised 342 patients (504 lesions) who underwent SES implantation between January 2002 and December 2004. The median duration of follow-up was 3816 days (interquartile range [Q1-Q3], 3,705-3,883 days). RESULTS: The cumulative event rate of definite stent thrombosis was 3.9%. The cumulative rate of target lesion revascularization (TLR) at 1, 5, and 10 years was 8.7%, 18.8%, and 31.1%, respectively, and the annual rate of TLR was 3.1%. Clinically driven TLR occurred at relatively constant rate during 10 years (2.0% per year). In a multivariate analysis, higher body mass index, hemodialysis, in-stent restenosis (ISR) target lesion, and total stent length >30 mm were independent risk factors of TLR within 5 years. An independent risk factor of TLR beyond 5 years was ISR target lesion. CONCLUSIONS: Late TLR after SES implantation is a long-term hazard, lasting up to 10 years. The ISR target lesion is a risk factor of TLR during 10 years.


Subject(s)
Coronary Restenosis , Drug-Eluting Stents/adverse effects , Long Term Adverse Effects , Myocardial Infarction , Percutaneous Coronary Intervention , Sirolimus , Aged , Aged, 80 and over , Coronary Restenosis/diagnosis , Coronary Restenosis/epidemiology , Coronary Restenosis/etiology , Female , Follow-Up Studies , Humans , Immunosuppressive Agents/administration & dosage , Immunosuppressive Agents/adverse effects , Japan/epidemiology , Long Term Adverse Effects/diagnosis , Long Term Adverse Effects/epidemiology , Long Term Adverse Effects/etiology , Male , Middle Aged , Myocardial Infarction/diagnosis , Myocardial Infarction/epidemiology , Myocardial Infarction/surgery , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Registries , Retrospective Studies , Risk Factors , Sirolimus/administration & dosage , Sirolimus/adverse effects
18.
Int J Cardiol ; 214: 123-9, 2016 Jul 01.
Article in English | MEDLINE | ID: mdl-27060271

ABSTRACT

BACKGROUND: Stent fracture (SF) after drug-eluting stent (DES) implantation was reported to be associated with target lesion revascularization (TLR). We have noted abnormal late acquired stent axial deformation in lesions after DES implantation, especially in SF lesions, and defined it as stent recoil (SR). We evaluated the incidence, predictive factors, and clinical impact of SR in SF lesions. METHODS: Between 2003 and 2012, 5456 patients (11,712 lesions) underwent DES implantations and follow-up angiography within one year after the index procedure. SR was defined as an axial recoil deformation less than 80% of the stent diameter and SF was defined as the separation of stent segments or stent struts. SF and SR were confirmed by follow-up angiography. The primary endpoint was defined as clinically driven TLR. RESULTS: SF was observed in 494 lesions (4.2%) and SR in 138 of SF lesions (27.9%). According to multinomial logistic regression analyses, severe calcification and ostial lesion in the right coronary artery were stronger predictive factors of SF with SR lesions. The cumulative incidences of any and clinically driven TLR at 5years were both significantly higher in the SF with SR group than in the SF without SR group (51.7% versus 35.0%, P<0.001; 22.2% versus 12.8%, P=0.019; respectively). CONCLUSIONS: SR in SF lesions after DES implantation could be related to the lesion characteristics. SF with SR was highly associated with subsequent TLR compared with SF without SR.


Subject(s)
Coronary Artery Disease/therapy , Coronary Stenosis/epidemiology , Drug-Eluting Stents/statistics & numerical data , Percutaneous Coronary Intervention/statistics & numerical data , Aged , Coronary Artery Disease/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Drug-Eluting Stents/adverse effects , Female , Humans , Incidence , Male , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Prosthesis Failure , Regression Analysis , Retrospective Studies , Risk Factors , Treatment Outcome , Vascular Calcification
19.
EuroIntervention ; 11(10): 1098-105, 2016 Feb.
Article in English | MEDLINE | ID: mdl-25692611

ABSTRACT

AIMS: The aim of this study was to compare the efficacy between paclitaxel-coated balloon (PCB) and drug-eluting stent (DES) implantation for the treatment of DES restenosis in complex situations. METHODS AND RESULTS: Data of patients who received revascularisation for DES restenosis between 2004 and 2011 were collected. A total of 683 patients with 777 lesions were analysed in this study (306 lesions treated by PCB, 471 lesions by DES). The use of PCB or DES was at the discretion of the operator. Angiographic outcomes at six to eight months and clinical outcomes at 12-month follow-up were compared between groups. The primary outcome was binary restenosis. Cox regression analysis with propensity score adjustment suggested that there were no significant differences between the two groups with respect to binary restenosis, target lesion revascularisation (TLR), and major adverse cardiac events. As for the angiographic endpoints, subgroup analysis was performed for several parameters. There was a significant trend favouring PCB with respect to binary restenosis and TLR in non-focal type lesions and bifurcation lesions. CONCLUSIONS: Angiographic and clinical outcomes in the PCB group were similar to those in the repeat DES group. PCB seemed to offer more favourable results in non-focal type lesions and bifurcation lesions.


Subject(s)
Cardiovascular Agents/therapeutic use , Coronary Restenosis/therapy , Drug-Eluting Stents , Paclitaxel/therapeutic use , Prosthesis Design , Aged , Angioplasty, Balloon, Coronary/methods , Female , Humans , Male , Middle Aged , Treatment Outcome
20.
Circ Cardiovasc Interv ; 8(8): e002664, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26227346

ABSTRACT

BACKGROUND: Stent fracture (SF) after sirolimus-eluting stent implantation is reported to be associated with target lesion revascularization (TLR) and stent thrombosis. We aimed to assess the clinical impact of SF at 8 years. METHODS AND RESULTS: Between 2002 and 2005, 972 patients (1795 lesions) underwent sirolimus-eluting stent implantation and follow-up angiography within 1 year after index procedure. SF, defined as the complete separation of stent segments or stent struts at follow-up angiography, was observed in 105 lesions (5.8%). The study sample comprised 954 patients (1630 lesions), excluding 147 lesions undergoing TLR and 18 patients (18 lesions) who died or in whom stent thrombosis developed within 1 year after sirolimus-eluting stent implantation. The median follow-up duration was 9.1 years (the first and third quarters, 8.7 and 9.4 years). The primary end point was defined as any TLR. The 8-year cumulative rates of adverse events were estimated by Kaplan-Meier methods with P values from log-rank tests. Between patients with and without SF, there were no significant differences in the cumulative rates of all-cause death (23.5% versus 27.6%, P=0.35) and cardiac death (4.7% versus 9.1%, P=0.14), whereas patients with SF had significantly higher cumulative rates in myocardial infarction (10.1% versus 3.3%, P=0.001), very late stent thrombosis (6.8% versus 0.7%, P<0.001), any TLR (38.1% versus 10.8%, P<0.001), and clinically driven TLR (26.2% versus 6.6%, P<0.001). CONCLUSIONS: SF after sirolimus-eluting stent implantation was consistently associated with higher rates of adverse cardiac events during the 8-year follow-up.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Coronary Artery Disease/therapy , Drug-Eluting Stents , Immunosuppressive Agents/administration & dosage , Prosthesis Failure , Sirolimus/administration & dosage , Aged , Coronary Angiography , Coronary Restenosis , Coronary Thrombosis/etiology , Coronary Thrombosis/mortality , Female , Humans , Male , Middle Aged , Myocardial Infarction/etiology , Myocardial Infarction/mortality , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...