Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Innovations (Phila) ; 18(3): 254-261, 2023.
Article in English | MEDLINE | ID: mdl-37227169

ABSTRACT

OBJECTIVE: Barbed nonabsorbable sutures have been widely adopted for tissue closure in noncardiac robotic surgery to improve intraoperative efficiency. Here, we examine the profile in robotic mitral valve repair (rMVR), which utilized barbed nonabsorbable sutures. To our knowledge, this is the first report to describe clinical outcomes for rMVR with barbed nonabsorbable sutures. METHODS: A retrospective review identified 90 patients who underwent rMVR using barbed nonabsorbable sutures at our center between 2019 and 2021. The primary outcome measure was dehiscence, while other relevant outcomes included 30-day readmission and 30-day mortality. RESULTS: In addition to fixation of the mitral annuloplasty band, barbed nonabsorbable sutures were employed commonly in concomitant pericardiectomy closure (100.0%, 90 of 90), atriotomy closure (100.0%, 90 of 90), and left atrial appendage closure (if eligible; 98.8%, 83 of 84). One patient who underwent mitral valve annuloplasty using only barbed nonabsorbable suture required reoperation for annuloplasty ring dehiscence. Immediate postoperative ring dehiscence was not observed in any patients after the routine reinforcement of barbed nonabsorbable sutures with everting pledgeted polyester sutures, and no additional patients required reoperation for suture-related complications. Clinical signs of dehiscence were not observed after pericardiectomy, atriotomy, or left atrial appendage closure with barbed nonabsorbable sutures. The 30-day readmission rate was 3.3% (3 of 90), and 30-day mortality was 0% (0 of 90). CONCLUSIONS: These data suggest the initial feasibility of barbed nonabsorbable sutures in robotic cardiac surgery, specifically within rMVR. Further research is necessary to explore the long-term safety and efficacy profile of such approach.


Subject(s)
Cardiac Surgical Procedures , Robotic Surgical Procedures , Humans , Robotic Surgical Procedures/adverse effects , Suture Techniques , Mitral Valve/surgery , Feasibility Studies , Sutures/adverse effects , Treatment Outcome
2.
J Surg Res ; 289: 35-41, 2023 09.
Article in English | MEDLINE | ID: mdl-37079964

ABSTRACT

INTRODUCTION: The robotic platform reduces the invasiveness of cardiac surgical procedures, thus facilitating earlier discharge in select patients. We sought to evaluate the characteristics, perioperative management, and early outcomes of patients who underwent postoperative day 1 or 2 (POD1-2) discharge after robotic cardiac surgery at our institution. METHODS: Retrospective review of 169 patients who underwent robotic cardiac surgery at our facility between 2019 and 2021 identified 57 patients discharged early on POD1 (n = 19) or POD2 (n = 38) and 112 patients who underwent standard discharge (POD3 or later). Relevant data were extracted and compared. RESULTS: In the early discharge group, median patient age was 62 [IQR: 55, 66] (IQR = interquartile range) years, and 70.2% (40/57) were male. Median Society of Thoracic Surgeons predictive risk of mortality score was 0.36 [IQR: 0.25, 0.56] %. The most common procedures performed were mitral valve repair [66.6%, (38/57)], atrial mass resection [10.5% (6/57)], and coronary artery bypass grafting [10.5% (6/57)]. The only significant differences between the POD1 and POD2 groups were shorter operative time, higher rate of in-operating room extubation, and shorter ICU length of stay in the POD1 group. Lower in-hospital morbidity and comparable 30-day mortality and readmission rates were observed between the early and standard discharge groups. CONCLUSIONS: POD1-2 discharge after various robotic cardiac operations afforded lower morbidity and similar 30-day readmission and mortality rates compared to discharge on POD3 or later. Our findings support the feasibility of POD1-2 discharge after robotic cardiac surgery for patients with low preoperative risk, an uncomplicated postoperative course, and appropriate postoperative management protocols.


Subject(s)
Cardiac Surgical Procedures , Robotic Surgical Procedures , Humans , Male , Aged , Female , Robotic Surgical Procedures/adverse effects , Robotic Surgical Procedures/methods , Patient Discharge , Feasibility Studies , Cardiac Surgical Procedures/adverse effects , Heart
3.
J Card Surg ; 37(12): 4803-4807, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36423256

ABSTRACT

OBJECTIVE: Prior studies have demonstrated robotic excision of cardiac tumors as a safe and effective treatment option. The procedure is performed with five incisions: three robotic arm ports, one atrial retractor port, and one working port. We report our unique initial experience in robotic tumor removal. To our knowledge, this is one of the first reports demonstrating cardiac myxoma and fibroelastoma removal with use of exclusively 8-mm ports. METHODS: All data for robotic cardiac tumor resection at our institution from June 2019 to December 2021 were retrospectively collected; 18 cases were included, including 13 cardiac myxomas and five fibroelastomas. Baseline demographics, intraoperative characteristics, and surgical outcomes were recorded. Descriptive statistics were calculated; continuous variables were reported as median [interquartile range], and categorical variables were reported as percentages. RESULTS: Median patient age was 64 [55, 70] years old. The cohort consisted of primarily female (67%) and white (83%) patients. Median body mass index was 26.3 [23.0, 31.5] kg/m2 . 11% of patients were current tobacco users and 50% had hypertension. All patients underwent myxoma or fibroelastoma removal with the use of five 8-mm robotic ports. Each patient underwent percutaneous cannulation via the femoral arteries. Aortic occlusion was achieved via an endoaortic balloon (67%) or transthoracic cross-clamp (33%). Cross-clamp time was 30 [26, 41] minutes. Concomitant procedures performed during myxoma removal included patent foramen ovale closure (28%), mitral valve repair (8%), left atrial appendage closure (8%), Cox-maze procedure (6%), and coronary artery bypass grafting (6%). All cardiac tumors were packaged with use of the endo-bag and subsequently removed through the working port. Maximal myxoma and fibroelastoma diameters were 2.5 [1.7, 3.5] and 0.6 [0.4, 0.7] cm, respectively. Procedural cardiopulmonary bypass time was 77 [65, 84] minutes. No intraoperative mortality, reoperation for bleeding, or postoperative cardiac issues were recorded. One in-hospital mortality occurred as the result of a thrombotic event in the context of a hypercoagulable state unrelated to the patient's operation. No other mortalities were observed at 30 days. Hospital length of stay was 4.5 [3.0, 7.8] days. CONCLUSIONS: In our study, the robotic platform facilitated safe and effective cardiac tumor excision. Our results highlight the efficacy of 8-mm port sizing and the concurrent use of other minimally invasive techniques, including percutaneous cannulation, in this patient population. In general, patients prefer the least invasive treatment option available. Our findings emphasize the importance of training cardiac surgeons to perform robotic procedures using the least invasive means possible to provide patients with various options for their treatment.


Subject(s)
Heart Neoplasms , Myxoma , Robotic Surgical Procedures , Humans , Female , Retrospective Studies , Heart Neoplasms/surgery , Heart Neoplasms/pathology , Catheterization , Myxoma/surgery , Minimally Invasive Surgical Procedures
4.
Ann Cardiothorac Surg ; 10(3): 375-382, 2021 May.
Article in English | MEDLINE | ID: mdl-34159118

ABSTRACT

BACKGROUND: The impact of left ventricular assist device (LVAD) complications on the individual patient, overall sentiment, and its effect on referral patterns, is not fully understood. We sought to better understand patient attitudes towards LVAD therapy using a computational sentiment analysis approach. METHODS: Posts, comments, and titles were parsed from MyLVAD.com's HTML as a text file using custom Python scripts (version 3.6). Individual word frequency was computed with word classification as 'positive', 'negative', or 'neutral'. Data transformation and cleaning, sentiment determination, and analysis was performed with a binary dictionary package using R software (version 3.6). RESULTS: Sixty-six thousand eight hundred and twenty-one unique words were noted, including 4,623 (6.9%) with positive sentiment and 3,248 (4.8%) with negative sentiment. Net sentiment ratio [(number of positive words - number of negative words)/(number of total words)] was 2.1%. Positive sentiment dominated the 20 most commonly used words. Odds ratio of non-neutral words [(number of positive words/number of negative words)] was 1.42, indicating a less obvious disparity in sentiment when expanding analysis beyond the top 20 words. Word cloud analysis of positive and negative sentiments was performed, indicating common use of "infection" (208 mentions) compared to other complications such as "stroke" (29 mentions), "bleeding" (30 mentions), and "thrombosis" or "clot" (32 mentions). CONCLUSIONS: Positive sentiment dominates the most frequently used words, yet this disparity decreases when considering the totality of words. "Infection" is mentioned a disproportionate number of times compared to other LVAD complications. Further research is required to address analysis limitations, including selection bias.

SELECTION OF CITATIONS
SEARCH DETAIL
...