Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Z Orthop Ihre Grenzgeb ; 143(6): 611-5, 2005.
Article in German | MEDLINE | ID: mdl-16380891

ABSTRACT

AIM: The goal of the current study was to determine the accuracy of free-hand and computer-assisted cup replacement. MATERIAL AND METHODS: We analysed the cup positions after 50 conventional instrumented THAs and compared them with the positions of 50 navigated cups. The operations were done between October 2002 and November 2004. To determine the accuracy of the cup position, the author developed a special measurement tool. With the help of the method it was ensured that the radiograph central beam reached the pelvis in a horizontal position. The central beam was focused directly on the head. We calculated the anteversion and the inclination. RESULTS: The variability of the cup position was significantly higher in the free-hand implanted group. The standard deviation for antetorsion in the navigation group was 5.0 and for inclination angles 2.8. In the conventionally implanted group the standard deviation was 7.4 for inclination and 6.9 for antetorsion. In particular, the anteversion cannot be exactly calculated without a navigation tool since the individual position of the patient's pelvis cannot be assessed by the surgeon without aids. Clinical long-term studies for the clarification of a higher stand-time of the computer-navigated cups are still necessary.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Joint Instability/diagnostic imaging , Joint Instability/surgery , Prosthesis Implantation/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Surgery, Computer-Assisted/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Treatment Outcome , User-Computer Interface
2.
Z Orthop Ihre Grenzgeb ; 137(2): 189-93, 1999.
Article in German | MEDLINE | ID: mdl-10408065

ABSTRACT

Osteoma cutis is a benign cutaneous disease which causes a primary heterotopic ossification of the skin. Corresponding to the appearance it is possible to distinguish four modifications. The enlargement of osteoma cutis can disturb the function of joints and statics. The etiology of the disease is unknown. Hamartoma or metaplasia is subject of discussion. It is important to mark off osteoma cutis from pseudohypoparathyreoidism (Albright-syndrome++).


Subject(s)
Ossification, Heterotopic/diagnostic imaging , Adult , Bone Malalignment/diagnostic imaging , Bone Malalignment/pathology , Diagnosis, Differential , Fascia/diagnostic imaging , Fascia/pathology , Humans , Leg Length Inequality/diagnostic imaging , Leg Length Inequality/pathology , Male , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/pathology , Ossification, Heterotopic/pathology , Radiography , Thigh/diagnostic imaging , Thigh/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...