Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Fa Yi Xue Za Zhi ; 38(1): 46-52, 2022 Feb 25.
Article in English, Chinese | MEDLINE | ID: mdl-35725703

ABSTRACT

OBJECTIVES: To construct a YOLOv3-based model for diatom identification in scanning electron microscope images, explore the application performance in practical cases and discuss the advantages of this model. METHODS: A total of 25 000 scanning electron microscopy images were collected at 1 500× as an initial image set, and input into the YOLOv3 network to train the identification model after experts' annotation and image processing. Diatom scanning electron microscopy images of lung, liver and kidney tissues taken from 8 drowning cases were identified by this model under the threshold of 0.4, 0.6 and 0.8 respectively, and were also identified by experts manually. The application performance of this model was evaluated through the recognition speed, recall rate and precision rate. RESULTS: The mean average precision of the model in the validation set and test set was 94.8% and 94.3%, respectively, and the average recall rate was 81.2% and 81.5%, respectively. The recognition speed of the model is more than 9 times faster than that of manual recognition. Under the threshold of 0.4, the mean recall rate and precision rate of diatoms in lung tissues were 89.6% and 87.8%, respectively. The overall recall rate in liver and kidney tissues was 100% and the precision rate was less than 5%. As the threshold increased, the recall rate in all tissues decreased and the precision rate increased. The F1 score of the model in lung tissues decreased with the increase of threshold, while the F1 score in liver and kidney tissues with the increase of threshold. CONCLUSIONS: The YOLOv3-based diatom electron microscope images automatic identification model works at a rapid speed and shows high recall rates in all tissues and high precision rates in lung tissues under an appropriate threshold. The identification model greatly reduces the workload of manual recognition, and has a good application prospect.


Subject(s)
Diatoms , Drowning , Drowning/diagnosis , Humans , Liver/diagnostic imaging , Lung/diagnostic imaging , Microscopy, Electron, Scanning
2.
Sci Total Environ ; 708: 135068, 2020 Mar 15.
Article in English | MEDLINE | ID: mdl-31780157

ABSTRACT

In-situ thin layer capping (TLC) is a promising sediment remediation approach that has been shown effective in immobilizing contaminants from releasing to natural biotas and human beings. This research intended to comprehend the effectiveness of Hg immobilization by TLC under turbation condition via a microcosm study. Three TLC caps with different activated carbon (AC)/clay combinations were applied to actual Hg-contaminated estuary sediment (76.0 ± 2.6 mg-Hg/kg). The caps with AC (3%) + bentonite (3%) and AC (3%) + kaolin (3%) were efficient in reducing both total mercury (THg) and methylmercury (MeHg) concentrations in overlying water by 75-95% and 64-98%, respectively, in the later stage of 75-d operation. In contrast, the AC (3%) + montmorillonite (3%) cap did not show a significant reduction on THg and MeHg in the overlying water, probably due to the unstable, suspension property of montmorillonite. The stable caps showed higher resistance to Hg breakthrough under occasional turbation events; however, a labile cap appeared to have dramatic Hg breakthrough when turbation occurred. It is therefore essential to note that with unstable caps, turbation events may result in unwanted secondary resuspension of contaminants.

SELECTION OF CITATIONS
SEARCH DETAIL
...