Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Dent Mater ; 40(5): 858-868, 2024 May.
Article in English | MEDLINE | ID: mdl-38616152

ABSTRACT

OBJECTIVES: This study evaluates the potential for osseointegration and remodeling of customized dental implants made from Titanium-Hydroxyapatite Functionally Graded Material (Ti-HAP FGM) with optimized geometry, using the finite element method (FEM). METHODS: The study utilized CT scan images to model and assemble various geometrical designs of dental implants in a mandibular slice. The mechanical properties of Ti-HAP FGMs were computed by varying volume fractions (VF) of hydroxyapatite (0-20%), and a bone remodeling algorithm was used to evaluate the biomechanical characteristics of the ultimate bone configuration in the peri-implant tissue. RESULTS: The findings of the FEA reveal that osseointegration improves with changes in the density and mechanical properties of the bone surrounding Ti-HAP implants, which are influenced by the varying VF of hydroxyapatite in the FGM. SIGNIFICANCE: Increasing the hydroxyapatite fraction improves osseointegration, and appropriate length and diameter selection of Ti-HAP dental implants contribute to their stability and longevity.


Subject(s)
Bone Remodeling , Dental Implants , Durapatite , Finite Element Analysis , Osseointegration , Titanium , Bone Remodeling/physiology , Durapatite/chemistry , Titanium/chemistry , Mandible , Tomography, X-Ray Computed , Humans , Biomechanical Phenomena , Dental Prosthesis Design , Algorithms , Materials Testing
2.
PLoS One ; 18(12): e0295582, 2023.
Article in English | MEDLINE | ID: mdl-38128035

ABSTRACT

This study investigates the biomechanical performance of various dental materials when filled in different cavity designs and their effects on surrounding dental tissues. Finite element models of three infected teeth with different cavity designs, Class I (occlusal), Class II mesial-occlusal (MO), and Class II mesio-occluso-distal (MOD) were constructed. These cavities were filled with amalgam, composites (Young's moduli of 10, 14, 18, 22, and 26 GPa), and glass carbomer cement (GCC). An occlusal load of 600 N was distributed on the top surface of the teeth to carry out simulations. The findings revealed that von Mises stress was higher in GCC material, with cavity Class I (46.01 MPa in the enamel, 23.61 MPa in the dentin), and for cavity Class II MO von Mises stress was 43.64 MPa, 39.18 MPa in enamel and dentin respectively, while in case of cavity Class II MOD von Mises stress was 44.67 MPa in enamel, 27.5 in the dentin. The results showed that higher stresses were generated in the non-restored tooth compared to the restored one, and increasing Young's modulus of restorative composite material decreases stresses in enamel and dentin. The use of composite material showed excellent performance which can be a good viable option for restorative material compared to other restorative materials.


Subject(s)
Composite Resins , Glass Ionomer Cements , Finite Element Analysis , Elastic Modulus , Dental Restoration, Permanent , Dental Stress Analysis , Stress, Mechanical
3.
Materials (Basel) ; 16(4)2023 Feb 10.
Article in English | MEDLINE | ID: mdl-36837128

ABSTRACT

In order to reduce the loosening of dental implants, surface modification with hydroxyapatite (HA) coating has shown promising results. Therefore, in this present study, the sol-gel technique has been employed to form a tantalum and strontium ion-doped hybrid HA layer coating onto the titanium (Ti)-alloy substrate. In this study, the surface modification was completed by using 3% tantalum pent oxide (Ta2O5), 3% strontium (Sr), and a combination of 1.5% Ta2O5 and 1.5% Sr as additives, along with HA gel by spin coating technique. These additives played a prominent role in producing a porous structure layer coating and further cell growth. The MG63 cell culture assay results indicated that due to the incorporation of strontium ions along with tantalum embedded in HA, cell proliferation increased significantly after a 48 h study. Therefore, the present results, including microstructure, crystal structure, binding energy, and cell proliferation, showed that the additives 1.5% Ta2O5 and 1.5% Sr embedded in HA on the Ti-substrate had an optimized porous coating structure, which will enhance bone in-growth in surface-modified Ti-implants. This material had a proper porous morphology with a roughness profile, which may be suitable for tissue in-growth between a surface-modified textured implant and bone interface and could be applicable for dental implants.

4.
Comput Biol Med ; 150: 106111, 2022 11.
Article in English | MEDLINE | ID: mdl-36195043

ABSTRACT

The long-term success of a dental implant is related to the material and design of the implant, and bone density. Conventional implants cause stress-shielding due to a mismatch between the implant and bone stiffness. Functionally graded porous materials and designs are a great choice for the design of implants to control the local stiffness at a certain location to meet the biomechanical requirements. The purpose of this study is to analyze five designs of axial and radial functionally graded materials (FGM) implants besides the conventional implant and conical and cylindrical shapes that were simulated with five different bone densities. The results showed that strain in bone increased with a decrease in cancellous bone density. The shape of the implant did not play an important role in strain/stress distribution. Conventional implants showed optimal strain (1000-2240 µÎµ) in low-density (0.7-0.8 g/cm3) bone, however, FGM implants produced optimal strain (990-1280 µÎµ) in the high-density bone (0.9-1 g/cm3) as compared to conventional implants. The proposed designs of FGM implants have the potential to address the complications of conventional implants in high-density bone.


Subject(s)
Bone Density , Dental Implants , Bone and Bones/surgery , Cancellous Bone , Finite Element Analysis , Stress, Mechanical , Biomechanical Phenomena , Dental Stress Analysis , Computer Simulation
5.
J Mech Behav Biomed Mater ; 134: 105422, 2022 10.
Article in English | MEDLINE | ID: mdl-36037710

ABSTRACT

Stress-shielding is caused by a significant mismatch in stiffness between bone tissue and Ti alloy dental implants. Therefore, in this study, a Ti-PEEK composite implant was examined and compared with conventional titanium, to determine the behavior of the host bone. Twelve 3D finite element models were modeled with two conditions of marginal cortical bone (with and without marginal bone loss). Six implant designs were constructed. Implant (A) was made with a conventional design (dense titanium), implants (B), (C) and (D) are designed with Ti-PEEK composite (outer layer made of PEEK and inner structures made of Ti with hexagonal, cylindrical, and cross shapes for implants (B), (C) and (D), respectively), the implant (E) is designed with Ti at the upper half section and PEEK at the bottom half section, and the implant (F) is designed with PEEK at the upper half section and Ti at the bottom half section. An axial load of 200 N was applied to the buccal cusp and central fossa of the occlusal surface. The displacements, stress, and equivalent strain were analyzed at the level of bone tissue. The mechanostat of Frost was used to determine the behavior of the cancellous bone under these biomechanical conditions. Results showed that strains were greater in cancellous bone with marginal bone loss than in healthy bone (w/o MBL). When compared to implants (B)-(F), conventional implant (A) did not produce as much strain. Thus, results and analyses suggest that the Ti-PEEK implants outperform compared with the implant (A) in the case of no marginal bone loss. However, the implants (A) and (E) perform equally in terms of bone loss.


Subject(s)
Dental Implants , Titanium , Benzophenones , Bone and Bones , Dental Stress Analysis , Finite Element Analysis , Ketones/chemistry , Polyethylene Glycols/chemistry , Polymers , Stress, Mechanical , Titanium/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...