1.
MAGMA ; 36(3): 355-373, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37171689

ABSTRACT

OBJECT: Lower-field MR is reemerging as a viable, potentially cost-effective alternative to high-field MR, thanks to advances in hardware, sequence design, and reconstruction over the past decades. Evaluation of lower field strengths, however, is limited by the availability of lower-field systems on the market and their considerable procurement costs. In this work, we demonstrate a low-cost, temporary alternative to purchasing a dedicated lower-field MR system. MATERIALS AND METHODS: By ramping down an existing clinical 3 T MRI system to 0.75 T, proton signals can be acquired using repurposed 13C transmit/receive hardware and the multi-nuclei spectrometer interface. We describe the ramp-down procedure and necessary software and hardware changes to the system. RESULTS: Apart from presenting system characterization results, we show in vivo examples of cardiac cine imaging, abdominal two- and three-point Dixon-type water/fat separation, water/fat-separated MR Fingerprinting, and point-resolved spectroscopy. In addition, the ramp-down approach allows unique comparisons of, e.g., gradient fidelity of the same MR system operated at different field strengths using the same receive chain, gradient coils, and amplifiers. DISCUSSION: Ramping down an existing MR system may be seen as a viable alternative for lower-field MR research in groups that already own multi-nuclei hardware and can also serve as a testing platform for custom-made multi-nuclei transmit/receive coils.


Subject(s)
Magnetic Resonance Imaging , Software , Magnetic Resonance Imaging/methods , Protons
2.
Magn Reson Med ; 79(6): 3256-3266, 2018 06.
Article in English | MEDLINE | ID: mdl-28983969

ABSTRACT

PURPOSE: The goal of this study was to devise a gradient system for MRI in humans that reconciles cutting-edge gradient strength with rapid switching and brings up the duty cycle to 100% at full continuous amplitude. Aiming to advance neuroimaging and short-T2 techniques, the hardware design focused on the head and the extremities as target anatomies. METHODS: A boundary element method with minimization of power dissipation and stored magnetic energy was used to design anatomy-targeted gradient coils with maximally relaxed geometry constraints. The design relies on hollow conductors for high-performance cooling and split coils to enable dual-mode gradient amplifier operation. With this approach, strength and slew rate specifications of either 100 mT/m with 1200 mT/m/ms or 200 mT/m with 600 mT/m/ms were reached at 100% duty cycle, assuming a standard gradient amplifier and cooling unit. RESULTS: After manufacturing, the specified values for maximum gradient strength, maximum switching rate, and field geometry were verified experimentally. In temperature measurements, maximum local values of 63°C were observed, confirming that the device can be operated continuously at full amplitude. Testing for peripheral nerve stimulation showed nearly unrestricted applicability in humans at full gradient performance. In measurements of acoustic noise, a maximum average sound pressure level of 132 dB(A) was determined. In vivo capability was demonstrated by head and knee imaging. Full gradient performance was employed with echo planar and zero echo time readouts. CONCLUSION: Combining extreme gradient strength and switching speed without duty cycle limitations, the described system offers unprecedented options for rapid and short-T2 imaging. Magn Reson Med 79:3256-3266, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Subject(s)
Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Equipment Design , Humans , Knee/diagnostic imaging , Male , Nonlinear Dynamics , Phantoms, Imaging , Temperature
3.
Radiother Oncol ; 86(1): 25-9, 2008 Jan.
Article in English | MEDLINE | ID: mdl-18023488

ABSTRACT

PURPOSE/OBJECTIVES: In radiotherapy the healthy tissue involvement still poses serious dose limitations. This results in sub-optimal tumour dose and complications. Daily image guided radiotherapy (IGRT) is the key development in radiation oncology to solve this problem. MRI yields superb soft-tissue visualization and provides several imaging modalities for identification of movements, function and physiology. Integrating MRI functionality with an accelerator can make these capacities available for high precision, real time IGRT. DESIGN AND RESULTS: The system being built at the University Medical Center Utrecht is a 1.5T MRI scanner, with diagnostic imaging functionality and quality, integrated with a 6MV radiotherapy accelerator. The realization of a prototype of this hybrid system is a joint effort between the Radiotherapy Department of the University of Utrecht, the Netherlands, Elekta, Crawley, U.K., and Philips Research, Hamburg, Germany. Basically, the design is a 1.5 T Philips Achieva MRI scanner with a Magnex closed bore magnet surrounded by a single energy (6 MV) Elekta accelerator. Monte Carlo simulations are used to investigate the radiation beam properties of the hybrid system, dosimetry equipment and for the construction of patient specific dose deposition kernels in the presence of a magnetic field. The latter are used to evaluate the IMRT capability of the integrated MRI linac. CONCLUSIONS: A prototype hybrid MRI/linac for on-line MRI guidance of radiotherapy (MRIgRT) is under construction. The aim of the system is to deliver the radiation dose with mm precision based on diagnostic quality MR images.


Subject(s)
Magnetic Resonance Imaging , Particle Accelerators , Radiotherapy Planning, Computer-Assisted , Humans , Particle Accelerators/instrumentation , Radiotherapy Dosage