Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Publication year range
1.
Perit Dial Int ; 41(1): 86-95, 2021 01.
Article in English | MEDLINE | ID: mdl-32048915

ABSTRACT

BACKGROUND: Ultrafiltration (UF) in peritoneal dialysis (PD) is mainly driven by the osmotic gradient and peritoneal permeability, but other factors-such as intraperitoneal pressure (IPP)-also have an influence. METHODS: To assess the clinical relevance of these marginal factors, we studied 41 unselected PD patients undergoing two consecutive 2 h, 2.27% glucose exchanges, first with 2.5 L and then with 1.5 L. RESULTS: IPP, higher in the 2.5 L exchange, had a wide interpatient range, was higher in obese and polycystic patients and their increase with infusion volume was higher for women regardless of body size. UF with 2.5 L correlated inversely with IPP and was higher for patients with polycystosis or hernias, while for 1.5 L we found no significant correlations. The effluent had higher glucose and osmolarity in the 2.5 L exchange than in the 1.5 L one, similar for both sexes. In spite of this stronger osmotic gradient, only 21 patients had more UF in the 2.5 L exchange, with differences up to 240 mL. The other 20 patients had more UF in the 1.5 L exchange, with stronger differences (up to 800 mL, and more than 240 mL for 9 patients). The second group, with similar effluent osmolarity and peritoneal equilibration test (PET) parameters than the first, has higher IPP and preponderance of men. The sex influence is so intense that men decreased average UF with 2.5 L with respect to 1.5 L, while women increased it. CONCLUSIONS: With 2.27% glucose, sex and IPP-modulated by obesity, polycystosis, hernias, and intraperitoneal volume-significantly affect UF in clinical settings and might be useful for its management.


Subject(s)
Peritoneal Dialysis , Ultrafiltration , Dialysis Solutions , Female , Glucose , Hernia , Humans , Male , Peritoneum
4.
NDT Plus ; 4(3): 195-7, 2011 Jun.
Article in English | MEDLINE | ID: mdl-25984156

ABSTRACT

We found chronic pneumoperitoneum in two continuous ambulatory peritoneal dialysis patients from two different hospitals. Both patients used the Stay.Safe® system and bicaVera solution, whose extension tubing is not primed with fluid but air-filled, unlike that of the conventional solution bags. This fact, together with a handling fault common to both patients, resulted in the inflow of the air in the tubing of bicaVera bags into the peritoneal cavity during every exchange. We warn of this complication, which must be specifically pointed out during training, and we recommend providing the system with a mechanic device to prevent this handling fault.

SELECTION OF CITATIONS
SEARCH DETAIL
...