Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Orthod Dentofacial Orthop ; 161(1): 46-52, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34509331

ABSTRACT

INTRODUCTION: This study aimed to investigate the effects of the strong occlusal force on the hemodynamics of gingival microcirculation. METHODS: Eleven adult volunteers with healthy periodontium and normal occlusion participated in this study. Using a noncontact laser Doppler flowmeter placed at the attached gingiva and the interdental papilla of the maxillary first premolar, changes in gingival blood flow (GBF) were examined during and after clenching. RESULTS: When the strong occlusal pressure was applied on the maxillary first premolar by clenching, GBF in the attached gingiva on the buccal side decreased significantly compared with the resting GBF, with medians of 2.3 mL/min/100 g and 5.4 mL/min/100 g, respectively (P <0.05). After the release of the maximum clenching, GBF recovered immediately and transiently increased to a median of 2.4 mL/min/100 g, showing a significant difference to the resting GBF (P <0.05). In contrast, in the interdental papilla, no significant change in GBF was found by clenching. CONCLUSIONS: Ischemia of the buccal attached gingiva associated with strong clenching may be due to compression of the vascular network of the periodontal membrane. Through reactive hyperemia resulting from the release of clenching, it is possible not only that blood flow will be restored to the tissue but that the tissue itself may be damaged by the reperfusion. During active orthodontic treatment, it is suggested that occlusal management to prevent occlusal trauma is important to avoid detrimental effects on periodontal tissues.


Subject(s)
Flowmeters , Gingiva , Adult , Hemodynamics , Humans , Laser-Doppler Flowmetry , Lasers , Pilot Projects , Regional Blood Flow
2.
J Orthod ; 48(4): 371-382, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34105424

ABSTRACT

OBJECTIVE: To evaluate the gingival condition due to adult orthodontic treatment using the clinical crown height (CCH) as an index. DESIGN: Retrospective study. SETTING: Department of Orthodontics at a university. PARTICIPANTS: A total of 21 adult female patients with healthy periodontal tissue were treated by means of the multi-bracket appliance with extraction of four first premolars. METHODS: Three-dimensional (3D) digital dental models were reconstructed to assess the vertical movement of the free gingival margin caused by adult orthodontic treatment. Pre- and post-treatment CCH were measured, and changes in CCH due to treatment were examined. RESULTS: The change in CCH by orthodontic treatment was able to be assessed objectively using 3D digital models of the dental casts. In the upper dentition, a significant reduction in CCH was found on the labial and lingual sides of the central incisor, with a mean of -0.28 mm and -0.34 mm, respectively (P < 0.001). In contrast, a significant increase in CCH was found on the labial side of the lateral incisor with a mean of 0.75 mm (P < 0.001). In the lower dentition, CCH on the lingual side of the canine, the second premolar and the first molar increased significantly (P < 0.001), with a mean of 0.41 mm, 0.45 mm and 0.50 mm, respectively. For the buccal side, the second premolar showed a significant increase in CCH with a mean of 0.61 mm (P < 0.001). CONCLUSION: By using the CCH as an index, it was possible to assess the gingival condition after active orthodontic treatment.


Subject(s)
Incisor , Molar , Bicuspid , Crowns , Female , Humans , Retrospective Studies , Tooth Movement Techniques
3.
Cranio ; 36(3): 181-188, 2018 May.
Article in English | MEDLINE | ID: mdl-28391764

ABSTRACT

OBJECTIVE: The aim of this study was to elucidate the physiological position of the proximal segment for postoperative jaw movement in patients with mandibular prognathism. METHODS: Twenty-two patients with mandibular prognathism were treated by orthognathic surgery using bilateral mandibular sagittal split ramus osteotomies (SSRO) with a physiological positioning strategy. The skeletal stability was assessed, and the movement of the proximal segment was evaluated by cephalography and computed tomography performed preoperatively, immediately postoperatively, and one year postoperatively. RESULTS: The patients were divided into two groups: the stable group (SNB relapse <1.5°) and the relapse group (SNB relapse ≥1.5°). In the stable group at one year postoperatively, the average SNB relapse was only 0.29° (7%), the condylar head had moved posteriorly by 0.75 mm, and the proximal segment had rotated counterclockwise by 1.2°. CONCLUSION: This new physiological positioning strategy improves the position of the condyle compared with the preoperative position in patients with mandibular prognathism.


Subject(s)
Mandibular Condyle/physiology , Osteotomy, Sagittal Split Ramus , Prognathism/physiopathology , Prognathism/surgery , Adolescent , Adult , Cephalometry , Female , Humans , Male , Mandibular Condyle/diagnostic imaging , Prognathism/diagnostic imaging , Tomography, X-Ray Computed , Young Adult
4.
Am J Orthod Dentofacial Orthop ; 150(6): 968-978, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27894546

ABSTRACT

INTRODUCTION: Most closing loops designed for producing higher moment-to-force (M/F) ratios require complex wire bending and are likely to cause hygiene problems and discomfort because of their complicated configurations. We aimed to develop a simple loop design that can produce optimal force and M/F ratio. METHODS: A loop design that can generate a high M/F ratio and the ideal force level was investigated by varying the portion and length of the cross-sectional reduction of a teardrop loop and the loop position. The forces and moments acting on closing loops were calculated using structural analysis based on the tangent stiffness method. RESULTS: An M/F ratio of 9.3 (high enough to achieve controlled movement of the anterior teeth) and an optimal force level of approximately 250 g of force can be generated by activation of a 10-mm-high teardrop loop whose cross-section of 0.019 × 0.025 or 0.021 × 0.025 in was reduced in thickness by 50% for a distance of 3 mm from the apex, located between a quarter and a third of the interbracket distance from the canine bracket. CONCLUSIONS: The simple loop design that we developed delivers an optimal force and an M/F ratio for the retraction of anterior teeth, and is applicable in a 0.022-in slot system.


Subject(s)
Orthodontic Space Closure/methods , Orthodontic Wires , Tooth Movement Techniques/methods , Dental Stress Analysis , Humans , Orthodontic Appliance Design , Orthodontic Brackets , Orthodontic Space Closure/instrumentation , Tooth Movement Techniques/instrumentation
5.
J Dent Biomech ; 6: 1758736014566337, 2015.
Article in English | MEDLINE | ID: mdl-25610497

ABSTRACT

The porpose of this study was to determine the optimal length of power arms for achieving controlled anterior tooth movement in segmented arch mechanics combined with power arm. A three-dimensional finite element method was applied for the simulation of en masse anterior tooth retraction in segmented power arm mechanics. The type of tooth movement, namely, the location of center of rotation of the maxillary central incisor in association with power arm length, was calculated after the retraction force was applied. When a 0.017 × 0.022-in archwire was inserted into the 0.018-in slot bracket, bodily movement was obtained at 9.1 mm length of power arm, namely, at the level of 1.8 mm above the center of resistance. In case a 0.018 × 0.025-in full-size archwire was used, bodily movement of the tooth was produced at the power arm length of 7.0 mm, namely, at the level of 0.3 mm below the center of resistance. Segmented arch mechanics required shorter length of power arms for achieving any type of controlled anterior tooth movement as compared to sliding mechanics. Therefore, this space closing mechanics could be widely applied even for the patients whose gingivobuccal fold is shallow. The segmented arch mechanics combined with power arm could provide higher amount of moment-to-force ratio sufficient for controlled anterior tooth movement without generating friction, and vertical forces when applying retraction force parallel to the occlusal plane. It is, therefore, considered that the segmented power arm mechanics has a simple appliance design and allows more efficient and controllable tooth movement.

6.
Am J Orthod Dentofacial Orthop ; 146(2): 166-74, 2014 Aug.
Article in English | MEDLINE | ID: mdl-25085299

ABSTRACT

INTRODUCTION: It has been found that controlled movement of the anterior teeth can be obtained by attaching a certain length of power arm onto an archwire in sliding mechanics. However, the impact of the archwire/bracket play on anterior tooth movement has not been clarified. The purpose of this study was to compare the effect of the power arm on anterior tooth movements with different dimensions of bracket slots and archwires. METHODS: A 3-dimensional finite element method was used to simulate en-masse anterior tooth retraction in sliding mechanics. Displacements of the maxillary central incisor and the archwire deformation were calculated when applying retraction forces from different lengths of power arms. RESULTS: When a 0.017 × 0.022-in archwire was engaged into the 0.018-in slot bracket, bodily movement of the incisor was obtained with 9.1-mm length of the power arm. When a 0.022-in slot system was coupled with a 0.019 × 0.025-in archwire, bodily movement was observed with a power arm length of 11.6 mm. CONCLUSIONS: Archwire/bracket play has a remarkable impact on anterior tooth movement. An effective torque application to the anterior teeth becomes clinically difficult in sliding mechanics combined with power arms when the archwire/bracket play is large.


Subject(s)
Finite Element Analysis , Imaging, Three-Dimensional/methods , Orthodontic Appliance Design , Orthodontic Brackets , Orthodontic Space Closure/methods , Orthodontic Wires , Tooth Movement Techniques/methods , Alveolar Process/physiology , Biomechanical Phenomena , Computer Simulation , Cone-Beam Computed Tomography/methods , Elastic Modulus , Humans , Image Processing, Computer-Assisted/methods , Incisor/physiopathology , Models, Biological , Orthodontic Space Closure/instrumentation , Periodontal Ligament/physiology , Tooth Movement Techniques/instrumentation , Torque
7.
J Dent Biomech ; 3: 1758736012461269, 2012.
Article in English | MEDLINE | ID: mdl-23115578

ABSTRACT

OBJECTIVES: The aim of this study was to clarify the effect of the play between the bracket and the archwire on anterior tooth movement subjected to the retraction force from various lengths of power arms in sliding mechanics. MATERIALS AND METHODS: A three-dimensional finite element method was used to simulate en masse anterior tooth retraction in sliding mechanics. The displacements of the maxillary incisor and the archwire deformation were calculated when the retraction force was applied. RESULTS: When a play did not exist, bodily movement was obtained at 5.0 mm length of power arm. In case a play existed, bodily movement was observed at the power arm length of 11.0 mm. CONCLUSIONS: In the actual clinical situation, a bracket/archwire play and the torsion of the archwire within the bracket slot should be taken into consideration to prescribe an optimal power arm length and to achieve effective anterior tooth movement.

SELECTION OF CITATIONS
SEARCH DETAIL
...