Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Vet Clin Pathol ; 53(2): 218-228, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38803017

ABSTRACT

BACKGROUND: Biochemical measurements are commonly evaluated using population-based reference intervals; however, there is a growing trend toward reassessing results with within-subject variation (CVI). OBJECTIVES: We aimed to estimate the CVI of 16 biochemical analytes using a large database of dogs and cats, which refers to the results of routine health checkups. METHODS: Pairs of sequential results for 16 analytes were extracted from a database of adult patients. The second result was divided by the first result to produce the ratio of sequential results (rr), and the frequency distribution of rr was plotted. From the plots, the coefficient of variation (CVrr) was calculated. Analytical variation (CVA) was calculated using quality control data, and CVI was estimated as follows: CV I = CV rr / 2 1 / 2 2 - CV A 2 1 / 2 . Estimated CVI was compared with previously reported CVI using the Bland-Altman plot analysis. RESULTS: From the database, 9078 data points from 3610 dogs and 3743 data points from 1473 cats were extracted, with 5468 data pairs for dogs and 2270 for cats. Sampling intervals ranged from 10 to 1970 days (median 366) for dogs and 23 to 1862 days (median 365) for cats. Bland-Altman analysis showed most CVI plots fell within the limits of agreement; however, positive fixed biases were observed in both dogs and cats. CONCLUSIONS: Our study introduces a novel approach of estimating CVI using routine health checkup data in dogs and cats. Despite biases, our method holds promise for clinical application in assessing the significance of measurement result differences.


Subject(s)
Databases, Factual , Dogs , Animals , Cats , Reference Values , Male , Female , Blood Chemical Analysis/veterinary
2.
Masui ; 58(11): 1418-23, 2009 Nov.
Article in Japanese | MEDLINE | ID: mdl-19928510

ABSTRACT

BACKGROUND: Clinical significance of PA catheter is controversial. FloTrac sensor bases its calculations on arterial waveform characteristics. We conducted a pilot assessment of the FloTrac sensor by three versions comparing with pulmonary artery catheter (PCA) methodology. METHODS: Five patients undergoing cardiac surgery and four patients undergoing renal transplantation were enrolled. A PAC was inserted and radial arterial access was used for semi-invasive determination of CO (APCO) with the Vigileo. CO was measured simultaneously by bolus thermodilution and the Vigileo technique, and CCO was measured simultaneously. RESULTS: The correlation with output obtained by FloTrac and obtained by PCA is better with the newer version. Bland Altman analyses demonstrated better agreement between FloTrac and PCA methodology of the newer version. CONCLUSIONS: CO measured by a new semi-invasive arterial pressure waveform analysis device showed better agreement with pulmonary artery thermodilution measurement of the newer version.


Subject(s)
Cardiac Output , Monitoring, Physiologic/instrumentation , Catheterization , Female , Humans , Male , Middle Aged , Monitoring, Physiologic/methods , Pilot Projects , Pulmonary Artery/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...