Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 49
Filter
1.
Ann Indian Acad Neurol ; 27(1): 46-52, 2024.
Article in English | MEDLINE | ID: mdl-38495254

ABSTRACT

Background: Atrial fibrillation (AF) is the main arrhythmia associated with thromboembolic complications and cognitive impairment. In this study, we aimed to evaluate the relationship between cognitive impairment and different scoring systems developed for AF to improve the medical follow-up of cognitive impairment. Methods: Between January 2019 and December 2020, 124 patients between the age of 30 and 80 years, diagnosed with AF for at least 5 years and complaining about memory impairment during cardiological follow-up, were included in the study. The patients were divided into two groups based on their cognitive status as assessed by the Mini-Mental State Examination group 1 consisted of 52 patients with cognitive impairment and group 2 comprised 72 patients without cognitive impairment. Results: The ATRIA bleeding score had a positive moderate correlation (r = 0.454, P < 0.001), the ATRIA stroke score had a strong correlation (r = 0.738, P < 0.001), and the SAMe-TT2R2 score had a strong correlation (r = 0.688, P < 0.001) with cognitive impairment. However, CHADS2 and CHA2DS2VASc scores were not statistically correlated with cognitive impairment. According to the receiver operating characteristic (ROC) curve, the area under the curve (AUC) of the ATRIA bleeding score was 0.761 with a 95% confidence interval (CI) of 0.678-0.844 and P < 0.001; also, for the ATRIA stroke score, AUC was 0.930 with a 95% CI of 0.886-0.974 and P < 0.001. In addition, for the SAMe-TT2R2 score, AUC was 0.895 with a 95% CI of 0.838-0.952 and P < 0.001. In the pairwise comparison of AUC on ROC curves, the ATRIA stroke score and the SAMe-TT2R2 score were statistically similar (P = 0.324). ATRIA bleeding, ATRIA stroke, and SAMe-TT2R2 scores were greater than CHADS2 stroke score (P: 0.0004, P < 0.0001, and P < 0.0001, respectively), but CHA2DS2-VASc and CHADS2 stroke scores were statistically similar (P: 0.402). Conclusion: Both ATRIA stroke and SAMe-TT2R2 scoring systems can provide a better correlation than CHADS2 and CHA2DS2-VASc scores in patients with AF to evaluate their cognitive status. These two scores can be more useful to monitor the patients with AF for medical follow-up of cognitive status.

2.
Inorg Chem ; 63(4): 2257-2267, 2024 Jan 29.
Article in English | MEDLINE | ID: mdl-38221778

ABSTRACT

Easy-to-synthesize aminoquinoline (AQ) appended naphthoquinone (NQ)-based colorimetric and ratiometric probe (AQNQ) was successfully synthesized in one step with high yield and low cost, and was utilized to supply an effective solution to critical shortcomings encountered in Cu2+ analysis. The structure of AQNQ and its interaction with Cu2+ forming an unusual AQNQ-Cu complex were enlightened with single-crystal X-ray diffraction analysis and different spectroscopic methods. AQNQ-Cu complex is the first Cu2+ containing dinuclear crystal where the octahedral coordination sphere is fulfilled through the coordination of a NQ oxygen atom. AQNQ exhibited long-term stability (more than 1 month), superior probe ability toward Cu2+ with quite fast response (30 s), high selectivity among many ions, and limit of detection of 12.13 ppb that is significantly below the highest amount of Cu2+ allowed in drinking water established by both WHO and EPA. Ratiometric determination of Cu2+ using AQNQ was performed with high recovery and low RSD values for drinking water, tap water, lake water, cherry, and watermelon samples. Colorimetric on-site determination including smartphone and paper strip applications, IMPLICATION, and INHIBIT logic gate applications were successfully carried out. The reversibility and reusability of the response to Cu2+ ions with the paper strip application were examined for the first time.

3.
Epilepsy Behav ; 151: 109622, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38219606

ABSTRACT

BACKGROUND: It is reported that antiepileptic drugs have an effect on balance functions. The aim of the study was to evaluate and compare the effects of valproic acid and levetiracetam monotherapy on balance functions in patients with generalized epilepsy using objective test methods. METHODS: The study included 43 generalized epilepsy patients aged 18-60 years, including 20 patients receiving valproic acid monotherapy, 23 patients receiving levetiracetam monotherapy, and 25 healthy individuals as controls, in the Neurology Clinic of a university hospital in eastern Turkey. The demographic data form was filled out and the Video Head Impulse Test and Vestibular Evoked Myogenic Potentials test were performed. RESULTS: Statistically significant differences were obtained between the groups in lateral, posterior, and anterior semicircular canal gains and RALP and LARP asymmetry values in the V-HIT test (p < 0.05). Statistically significant differences were obtained between the groups in P1, N1 latency and asymmetry values in the C-VEMP test and in N1, P1 latency, amplitude, and asymmetry values in the o-VEMP test (p < 0.05). CONCLUSION: Valproic acid and levetiracetam may affect the vestibulocular and vestibulocolic reflex pathways negatively. In this cohort, valproic acid had more pronounced adverse effects on balance functions as compared to levetiracetam.


Subject(s)
Epilepsy, Generalized , Valproic Acid , Humans , Levetiracetam/therapeutic use , Valproic Acid/adverse effects , Anticonvulsants/adverse effects , Epilepsy, Generalized/drug therapy , Research Design
4.
Angiology ; 75(3): 267-273, 2024 Mar.
Article in English | MEDLINE | ID: mdl-36628494

ABSTRACT

Considering the increasing use of the transcatheter aortic valve implantation (TAVI) procedure, the relationship of contrast-induced nephropathy (CIN) with post-TAVI mortality has become important. The Mehran score was developed to detect the risk of CIN development after cardiac intervention. We aimed to compare the role of the modified Mehran score, which can be calculated pre-procedure, in predicting CIN development and compare it with the original Mehran score. We retrospectively collected data from TAVI procedures at our institution between December 2016 and June 2021; of 171 patients, 44 (25.7%) had CIN. We found no association between contrast media volume and CIN (387 ± 120 vs 418 ± 139 mL, P = .303). High and very high modified Mehran score and preoperative C-reactive protein (CRP) level were independent risk factors for CIN development after TAVI procedure. The area under curve (AUC) was .686 with 95% CI: .591-.780 and P < .001, and also, with a cut-off point of >7.5 points, there was 79.5% sensitivity and 63.0% specificity; otherwise, with a cut-off point of >9.5 points, there was 54.5% sensitivity and 71.7% specificity, for the modified Mehran score. The modified Mehran score comes into prominence compared with the original Mehran score since it can be calculated pre-procedure.


Subject(s)
Aortic Valve Stenosis , Kidney Diseases , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Retrospective Studies , Contrast Media/adverse effects , Kidney Diseases/chemically induced , Kidney Diseases/diagnosis , Kidney Diseases/surgery , Risk Factors , Aortic Valve Stenosis/surgery , Aortic Valve/surgery
5.
Front Neurol ; 14: 1300651, 2023.
Article in English | MEDLINE | ID: mdl-38073646

ABSTRACT

Objectives: This study aimed to determine the normative values of the functional head impulse test (fHIT) test in healthy young adults. Materials and methods: The study included 100 individuals, 58 females and 42 males, aged 20-25 years. Beon Solution Zero Branco (TV) fHIT test was applied to all participants. FHIT results were analyzed in terms of lateral-posterior-anterior semicircular canals (SSCs), gender, and right-left ear. Results: In the fHIT test, for the lateral SSC the mean percent correct answer (%CA) values for 4,000-6,000°/s2 and 1,000-7,000°/s2 were 88.52 ± 9.04 and 89.91 ± 6.95, respectively; for the posterior SSC, the mean %CA values for SSC 3000-6,000°/s2 and 1,000-7,000°/s2 were 90.63 ± 8.69 and 91.16 ± 7.42, respectively; for the anterior SSC, the mean %CA values for 3,000-6,000°/s2 and 1,000-7,000°/s2 were 91.21 ± 7.96 and 91.49 ± 7.13, respectively. There was no statistically significant difference between the right and left ear in %CA values at all accelerations in all SSCs (p > 0.05). There was a statistically significant difference between genders in the mean %CA values for 6,000-7,000°/s2, 4,000-6,000°/s2, and 1,000-7,000°/s2 in the lateral SSC and 3,000-6,000°/s2 in the anterior SSC (p < 0.05). Conclusion: The FHIT is a noninvasive test battery that functionally evaluates the VOR of the six semicircular canals. In clinical use, the determination of normative values at all accelerations (1,000-7,000 degrees/s2) constitutes an important database for future studies to distinguish pathologic results.

6.
Jt Dis Relat Surg ; 34(2): 389-395, 2023 Apr 26.
Article in English | MEDLINE | ID: mdl-37462643

ABSTRACT

OBJECTIVES: In this study, we aimed to identify the most frequently reported claims after total hip arthroplasty (THA) and the reasons put forward by the plaintiffs. PATIENTS AND METHODS: Between January 2011 and December 2020, data of a total of 74 cases (21 males, 53 females; mean age: 53.7±12.8 years; range, 29 to 83 years) obtained from the Turkish Forensic Medicine Institute were retrospectively analyzed. Claims for litigation, demographic data, data regarding the identity of the accused and the hospital setting were recorded. RESULTS: The most common reason for lawsuits was death (n=15; 20.3%), followed by nerve injury (n=13; 17.6%), and eight patients had more than one complaint. According to the forensic medicine reports, malpractice was detected in 10 (12.5%) of the cases. Among the hospital types, only nerve injury made a significant difference among all complaint sources in different hospital settings (p=0.003). CONCLUSION: In our study, death was the most common reason for lawsuits regarding malpractice accusations after THA, which is different from medical malpractice allegations throughout the world.


Subject(s)
Arthroplasty, Replacement, Hip , Malpractice , Male , Female , Humans , Adult , Middle Aged , Aged , Arthroplasty, Replacement, Hip/adverse effects , Retrospective Studies , Databases, Factual
7.
Talanta ; 261: 124660, 2023 Aug 15.
Article in English | MEDLINE | ID: mdl-37207509

ABSTRACT

Detection of bisulfite (HSO3-) in food and beverages has vital importance because the excessive amount leads to ill effects on the human body. Colorimetric and fluorometric chromenylium-cyanine-based chemosensor CyR was synthesized and applied for high selective and sensitive analysis of HSO3- in red wine, rose wine and, granulated sugar with high recovery ranges and very fast response time without any interference from other competitive species. The limits of detection (LOD) for the UV-Vis and fluorescence titrations were found as 11.5 µM and 3.77 µM, respectively. The on-site and very rapid methods based on paper strips and smartphone which depend on the color changes from yellow to green have been successfully developed to analyze HSO3- concentration (10-5-10-1 M for paper strip and 163-1205 µM for smartphone). CyR and the bisulfite-adduct formed in the nucleophilic addition reaction with HSO3- were verified by FT-IR, 1H NMR, and MALDI-TOF results as well as Single-Crystal X-Ray Crystallography for CyR.


Subject(s)
Fluorescent Dyes , Wine , Humans , Fluorescent Dyes/chemistry , Colorimetry/methods , Smartphone , Spectroscopy, Fourier Transform Infrared , Wine/analysis
8.
Spectrochim Acta A Mol Biomol Spectrosc ; 297: 122725, 2023 Sep 05.
Article in English | MEDLINE | ID: mdl-37075687

ABSTRACT

A new near-infrared, spectrophotometric, and colorimetric probe based on a phthalocyanine-containing mercaptoquinoline unit (MQZnPc) has been constructed and utilized for discriminative and highly selective/sensitive detection of Ag+, Cu2+, and Hg2+ ions by using proper masking agents like EDTA, KI, and NaCl. The probe only responds to Ag+, Cu2+, and Hg2+ among the tested ions without any interference. The probe performs quite well (the limit of detection: 160 ppb, 148 ppb, and 276 ppb of Ag+, Cu2+, and Hg2+ions for UV-Vis, and 15 ppb, 37 ppb, and 467 ppb of Ag+, Cu2+, and Hg2+ ions for fluorescence, respectively), and has a fast response time (150 sec, 90 sec, and 90 sec of Ag+, Cu2+, and Hg2+ions for UV-Vis, and 300 sec, 240 sec, and 90 sec Ag+, Cu2+, and Hg2+ions for fluorescence, respectively). The probe also displays a colorimetric feature for UV-Vis and smartphone applications. Based on a single probe, Ag+, Cu2+, and Hg2+ ions which are the main toxic water contaminants could be recognized very quickly and colorimetrically with high recovery values in tap water samples. This study stands out with its unique properties compared to the related studies in the literature.

9.
Talanta ; 259: 124471, 2023 Jul 01.
Article in English | MEDLINE | ID: mdl-37001401

ABSTRACT

The objective of the study is, for the first time, to construct a new near infrared (NIR) fluorophore, spectrophotometric, colorimetric, ratiometric, and turn-on probe (CSME) based on chromenylium cyanine platform decorated with methionine biomolecule to provide an efficient solution for critical shortcoming to be encountered for analysis of hazardous Hg2+ in environment and living cell. The CSME structure and its interaction with Hg2+ ion were evaluated by NMR, FTIR, MS, UV-Vis and fluorescence methods as well as Density Functional Theory (DFT) calculations. The none fluorescence CSME having spirolactam ring only interacted with Hg2+ in aqueous solution including competing ions. This interaction caused the fluorescence CSME with opened spirolactam form which exhibited spectral and colorimetric changes in the NIR region. The probe based on UV-Vis and fluorescence techniques respond in 90 s, has wide linear ranges (for UV-Vis: 6.29 × 10-8 - 1.86 × 10-4 M; for fluorescence: 9.49 × 10-9 - 1.13 × 10-5 M), and has a lower Limit of Detection (LOD) value (for fluorescence: 4.93 × 10-9 M, 0.99 ng/mL) than the value predicted by the US Environmental Protection Agency (EPA) organization. Hg2+ analysis was performed in drinking and tap water with low Relative Standard Deviation (RSD) values and high recovery. Smartphone and living cell applications were successfully performed for colorimetric sensing Hg2+ in real samples and 3T3 cells, respectively.


Subject(s)
Fluorescent Dyes , Mercury , Mice , Animals , Fluorescent Dyes/chemistry , Methionine , Water/chemistry , Racemethionine , Mercury/analysis
10.
Cardiol Young ; 33(9): 1757-1759, 2023 Sep.
Article in English | MEDLINE | ID: mdl-36991557

ABSTRACT

Patent foramen ovale closure is recommended for patients who are at risk for recurrent paradoxical embolism and cryptogenic stroke. The standard technique of patent foramen ovale closure is established from the femoral vein. However, alternative methods may be necessary for patent foramen ovale closure as in every interventional procedure. A 45-year-old female patient with an intramural giant uterine myoma had a history of recurrent deep vein thrombosis and stroke. A diffuse thrombus was detected in both iliac veins associated with inferior vena cava compression of the myoma. Also, a patent foramen ovale was revealed on echocardiography as a cause of embolic events. Hysterectomy was initially planned by gynaecology, but due to the possible risk of embolisation of inferior vena cava thrombus and stroke after removal of the compressive mass during hysterectomy, initial patent foramen ovale closure and then hysterectomy was scheduled in the Gynecology-Cardiology-Cardivascular Surgery council. Patent foramen ovale closure was performed via the right jugular vein approach. But because of the tight left atrial ostium of the patent foramen ovale, the catheter could not pass to the left atrium from the right atrium. With an anchor of a 5.0 × 15 mm coronary balloon over a 0.014-inch guidewire to the pulmonary vein, we were able to reach the left atrium. The patent foramen ovale was closed successfully, and the patient underwent a hysterectomy after closure without any embolic event. The patient was asymptomatic at 6 months of control.


Subject(s)
Foramen Ovale, Patent , Pulmonary Veins , Stroke , Thrombosis , Venous Thrombosis , Female , Humans , Middle Aged , Foramen Ovale, Patent/complications , Foramen Ovale, Patent/surgery , Vena Cava, Inferior , Pulmonary Veins/surgery , Stroke/etiology , Venous Thrombosis/etiology , Venous Thrombosis/surgery , Thrombosis/complications
11.
Metab Eng ; 76: 179-192, 2023 03.
Article in English | MEDLINE | ID: mdl-36738854

ABSTRACT

Although strain tolerance to high product concentrations is a barrier to the economically viable biomanufacturing of industrial chemicals, chemical tolerance mechanisms are often unknown. To reveal tolerance mechanisms, an automated platform was utilized to evolve Escherichia coli to grow optimally in the presence of 11 industrial chemicals (1,2-propanediol, 2,3-butanediol, glutarate, adipate, putrescine, hexamethylenediamine, butanol, isobutyrate, coumarate, octanoate, hexanoate), reaching tolerance at concentrations 60%-400% higher than initial toxic levels. Sequencing genomes of 223 isolates from 89 populations, reverse engineering, and cross-compound tolerance profiling were employed to uncover tolerance mechanisms. We show that: 1) cells are tolerized via frequent mutation of membrane transporters or cell wall-associated proteins (e.g., ProV, KgtP, SapB, NagA, NagC, MreB), transcription and translation machineries (e.g., RpoA, RpoB, RpoC, RpsA, RpsG, NusA, Rho), stress signaling proteins (e.g., RelA, SspA, SpoT, YobF), and for certain chemicals, regulators and enzymes in metabolism (e.g., MetJ, NadR, GudD, PurT); 2) osmotic stress plays a significant role in tolerance when chemical concentrations exceed a general threshold and mutated genes frequently overlap with those enabling chemical tolerance in membrane transporters and cell wall-associated proteins; 3) tolerization to a specific chemical generally improves tolerance to structurally similar compounds whereas a tradeoff can occur on dissimilar chemicals, and 4) using pre-tolerized starting isolates can hugely enhance the subsequent production of chemicals when a production pathway is inserted in many, but not all, evolved tolerized host strains, underpinning the need for evolving multiple parallel populations. Taken as a whole, this study provides a comprehensive genotype-phenotype map based on identified mutations and growth phenotypes for 223 chemical tolerant isolates.


Subject(s)
Escherichia coli Proteins , Escherichia coli , Escherichia coli/genetics , Escherichia coli/metabolism , Escherichia coli Proteins/genetics , Escherichia coli Proteins/metabolism , Mutation , 1-Butanol/metabolism , Membrane Transport Proteins/genetics , Repressor Proteins/genetics , Transcriptional Elongation Factors/genetics , Transcriptional Elongation Factors/metabolism
12.
Arq Bras Cardiol ; 120(1): e20220287, 2023.
Article in English, Portuguese | MEDLINE | ID: mdl-36629604

ABSTRACT

BACKGROUND: A new clinical manifestation called post or long coronavirus disease (p/l COVID) has walked into our lives after the acute COVID-19 phase. P/l COVID may lead to myocardial injury with subsequent cardiac problems. Diagnosing these patients quickly and simply has become more important due to the increasing number of patients with p/l COVID. OBJECTIVES: We compared strain echocardiography (SE) parameters of patients who suffered from atypical chest pain and had sequel myocarditis findings on cardiac magnetic resonance (CMR). We aimed to investigate the value of SE for detection of myocardial involvement in patients with p/l COVID. METHODS: A total of 42 patients were enrolled. Our population was separated into two groups. The CMR(-) group (n = 21) had no myocardial sequelae on CMR, whereas the CMR(+) group had myocardial sequelae on CMR (n = 21). The predictive value of SE for myocarditis was also evaluated by age-adjusted multivariate analysis. P values < 0.05 were considered statistically significant. RESULTS: When compared with left ventricular ejection fraction (LVEF), global longitudinal strain (GLS) and global circumferential strain (GCS) had a stronger relationship (LVEF, p = 0.05; GLS, p < 0.001; GCS, p < 0.001) with p/l COVID associated myocardial involvement. GLS < 20.35 had 85.7% sensitivity and 81% specificity; GCS < 21.35 had 81% sensitivity and 81% specificity as diagnostic values for myocardial sequelae detected with CMR. While there was no difference between the groups in terms of inflammatory markers (C-reactive protein, p = 0.31), a difference was observed between biochemical markers, which are indicators of cardiac involvement (brain natriuretic peptide, p < 0.001). CONCLUSION: SE is more useful than traditional echocardiography for making diagnosis quickly and accurately in order not to delay treatment in the presence of myocardial involvement.


FUNDAMENTO: Tem surgido uma nova manifestação clínica chamada pós-COVID ou COVID longa (COVID p/l) após a fase aguda da COVID-19. COVID p/l pode levar à lesão miocárdica com problemas cardíacos subsequentes. Diagnosticar esses pacientes de forma rápida e simples é cada vez mais importante devido ao número crescente de pacientes com COVID p/l. OBJETIVOS: Comparamos os parâmetros de ecocardiografia com strain (ES) de pacientes que apresentaram dor torácica atípica e achados de sequelas de miocardite na ressonância magnética cardíaca (RMC). Nosso objetivo foi investigar o valor da ES para detecção de envolvimento miocárdico em pacientes com COVID p/l. MÉTODOS: Foram incluídos um total de 42 pacientes. Nossa população foi separada em 2 grupos. O grupo RMC(-) (n = 21) não apresentou sequelas miocárdicas na RMC, enquanto o grupo RMC(+) apresentou sequelas miocárdicas na RMC (n = 21). O valor preditivo da ES para miocardite também foi avaliado por análise multivariada ajustada por idade. Valores de p < 0,05 foram considerados estatisticamente significativos. RESULTADOS: Quando comparado com a fração de ejeção do ventrículo esquerdo (FEVE), o strain longitudinal global (SLG) e o strain circunferencial global (SCG) tiveram uma relação mais forte (FEVE, p = 0,05; SLG, p < 0,001; SCG, p < 0,001) com envolvimento miocárdico associado à COVID p/l. SLG < 20,35 apresentou sensibilidade de 85,7% e especificidade de 81%; SCG < 21,35 apresentou sensibilidade de 81% e especificidade de 81% como valores diagnósticos para sequelas miocárdicas detectadas com RMC. Enquanto não houve diferença entre os grupos quanto aos marcadores inflamatórios (proteína C-reativa, p = 0,31), houve diferença entre os marcadores bioquímicos, que são indicadores de envolvimento cardíaco (peptídeo natriurético cerebral, p < 0,001). CONCLUSÃO: A ES é mais útil do que a ecocardiografia tradicional para diagnosticar com rapidez e precisão, a fim de não atrasar o tratamento na presença de envolvimento miocárdico.


Subject(s)
COVID-19 , Myocarditis , Humans , Ventricular Function, Left , Stroke Volume , Myocarditis/diagnostic imaging , Myocarditis/etiology , COVID-19/complications , COVID-19/diagnostic imaging , Magnetic Resonance Imaging, Cine , Echocardiography , Chest Pain/diagnostic imaging , Chest Pain/etiology , Predictive Value of Tests
13.
Spectrochim Acta A Mol Biomol Spectrosc ; 287(Pt 2): 122060, 2023 Feb 15.
Article in English | MEDLINE | ID: mdl-36395583

ABSTRACT

A new dual-channel probe based on rhodamine B derivative (MSB) was successfully designed, synthesized, characterized by Nuclear Magnetic Resonance (NMR) Spectroscopy, Fourier Transform Infrared Spectrophotometer (FTIR), Matrix Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry (MALDI-TOF MS), X-ray Photoelectron Spectroscopy (XPS), and Single Crystal X-rayDiffraction, and the sensing abilities toward Fe3+ cation have been demonstrated and the probe was successfully utilized for fluorescence imaging of Fe3+ in living cells. The probe demonstrated quite fast, sensitive, and selective response to Fe3+ by causing an extreme enhancement in UV-vis and fluorescence spectroscopy techniques in the buffered aqueous media which makes MSB a dual-channel probe. While the color of MSB solution was initially light yellow, it turned pink in the presence of Fe3+, which provided highly selective naked-eye determination among several ions as alkaline, alkaline-earth, and transition metal ions. After that, the probe was easily applied to paper strips and real samples such as drinking waters and supplementary iron tablets for sensing Fe3+ in an aqueous solution. The detection limit (LOD) and the response time of the probe were determined as 4.85x10-9 M and 4 min, respectively, which are quite lower compared with other rhodamine based Fe3+ sensors in the literature. According to Job's plot, 1H NMR titration, MALDI-TOF MS, XPS, and DFT study techniques, the complexation ratio between MSB and Fe3+ was found as 1:1. Moreover, the spectral response was reversible with alternately addition of Fe3+ or Na2EDTA to the MSB solution. In addition, fluorescence imaging in NIH/3T3 mouse fibroblast cells and studies in real samples with a quite high recovery rate exhibited that the probe is qualified for detection of Fe3+ ion with multiple practical usages.


Subject(s)
Optical Imaging , Smartphone , Animals , Mice , Rhodamines , Photoelectron Spectroscopy , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization
14.
Spectrochim Acta A Mol Biomol Spectrosc ; 284: 121484, 2023 Jan 05.
Article in English | MEDLINE | ID: mdl-35729029

ABSTRACT

The aim of this work is to construct a new A2B2-type of unsymmetrical and ratiometric phthalocyanine (Pc) based-probe O-A2B2ZnPc to provide an effective solution to critical inadequacy to be experienced for the detection of hazardous Be2+. O-A2B2ZnPc enabling strong absorption and emission in Near-Infrared region (λabs-λem wavelengths of 694-712 nm) showed excellent selectivity and sensitivity toward Be2+ among competitive metal ions by both spectrophotometric and fluorometric methods. The probe with oligomeric Pc form in THF was degraded with the addition of aqueous Be2+ and arranged to J-aggregation form, resulting in a remarkably diminishing in Q-band at 694 nm as well as a new band formation at 746 nm, and a considerably decreasing in fluorescence emission. The probe has superior features for the determination of Be2+ such as high quantum efficiency and photochemical stability, rapid response (1 s), high selectivity and very low Limit of Detection (0.26 ppb and 1.5 ppb) for UV-Vis and fluorescence, respectively which are quite good values according to the permissible amount of Be2+ (4 ppb) in water as specified by World Health Organization. O-A2B2ZnPc can be shown among the best performing probes with its unique properties according to previous studies in the literature. In addition, the geometrical and spectral features of the O-A2B2ZnPc were analyzed in detail by DFT calculations.


Subject(s)
Fluorescent Dyes , Isoindoles , Fluorescent Dyes/chemistry , Indoles , Organometallic Compounds , Spectrometry, Fluorescence/methods , Water/chemistry
15.
Arq. bras. cardiol ; 120(1): e20220287, 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1420151

ABSTRACT

Resumo Fundamento Tem surgido uma nova manifestação clínica chamada pós-COVID ou COVID longa (COVID p/l) após a fase aguda da COVID-19. COVID p/l pode levar à lesão miocárdica com problemas cardíacos subsequentes. Diagnosticar esses pacientes de forma rápida e simples é cada vez mais importante devido ao número crescente de pacientes com COVID p/l. Objetivos Comparamos os parâmetros de ecocardiografia com strain (ES) de pacientes que apresentaram dor torácica atípica e achados de sequelas de miocardite na ressonância magnética cardíaca (RMC). Nosso objetivo foi investigar o valor da ES para detecção de envolvimento miocárdico em pacientes com COVID p/l. Métodos Foram incluídos um total de 42 pacientes. Nossa população foi separada em 2 grupos. O grupo RMC(-) (n = 21) não apresentou sequelas miocárdicas na RMC, enquanto o grupo RMC(+) apresentou sequelas miocárdicas na RMC (n = 21). O valor preditivo da ES para miocardite também foi avaliado por análise multivariada ajustada por idade. Valores de p < 0,05 foram considerados estatisticamente significativos. Resultados Quando comparado com a fração de ejeção do ventrículo esquerdo (FEVE), o strain longitudinal global (SLG) e o strain circunferencial global (SCG) tiveram uma relação mais forte (FEVE, p = 0,05; SLG, p < 0,001; SCG, p < 0,001) com envolvimento miocárdico associado à COVID p/l. SLG < 20,35 apresentou sensibilidade de 85,7% e especificidade de 81%; SCG < 21,35 apresentou sensibilidade de 81% e especificidade de 81% como valores diagnósticos para sequelas miocárdicas detectadas com RMC. Enquanto não houve diferença entre os grupos quanto aos marcadores inflamatórios (proteína C-reativa, p = 0,31), houve diferença entre os marcadores bioquímicos, que são indicadores de envolvimento cardíaco (peptídeo natriurético cerebral, p < 0,001). Conclusão A ES é mais útil do que a ecocardiografia tradicional para diagnosticar com rapidez e precisão, a fim de não atrasar o tratamento na presença de envolvimento miocárdico.


Abstract Background A new clinical manifestation called post or long coronavirus disease (p/l COVID) has walked into our lives after the acute COVID-19 phase. P/l COVID may lead to myocardial injury with subsequent cardiac problems. Diagnosing these patients quickly and simply has become more important due to the increasing number of patients with p/l COVID. Objectives We compared strain echocardiography (SE) parameters of patients who suffered from atypical chest pain and had sequel myocarditis findings on cardiac magnetic resonance (CMR). We aimed to investigate the value of SE for detection of myocardial involvement in patients with p/l COVID. Methods A total of 42 patients were enrolled. Our population was separated into two groups. The CMR(-) group (n = 21) had no myocardial sequelae on CMR, whereas the CMR(+) group had myocardial sequelae on CMR (n = 21). The predictive value of SE for myocarditis was also evaluated by age-adjusted multivariate analysis. P values < 0.05 were considered statistically significant. Results When compared with left ventricular ejection fraction (LVEF), global longitudinal strain (GLS) and global circumferential strain (GCS) had a stronger relationship (LVEF, p = 0.05; GLS, p < 0.001; GCS, p < 0.001) with p/l COVID associated myocardial involvement. GLS < 20.35 had 85.7% sensitivity and 81% specificity; GCS < 21.35 had 81% sensitivity and 81% specificity as diagnostic values for myocardial sequelae detected with CMR. While there was no difference between the groups in terms of inflammatory markers (C-reactive protein, p = 0.31), a difference was observed between biochemical markers, which are indicators of cardiac involvement (brain natriuretic peptide, p < 0.001). Conclusion SE is more useful than traditional echocardiography for making diagnosis quickly and accurately in order not to delay treatment in the presence of myocardial involvement.

16.
Turk Kardiyol Dern Ars ; 50(6): 407-414, 2022 09.
Article in English | MEDLINE | ID: mdl-36068979

ABSTRACT

OBJECTIVE: MicroRNAs have been explored as potential biomarkers for many pathological processes including coronary artery disease. In this study, we aimed to compare the circulating levels of selected atherosclerosis-associated miRNAs in patients with a history of early-onset coronary artery disease with that of age- and sex-matched healthy controls and older patients with late-onset coronary artery disease. METHODS: Study population consisted of 30 patients with early onset coronary artery disease, 31 age- and sex-matched healthy controls, and 30 patients with late-onset coronary artery disease. Plasma levels of 13 microRNAs (endothelial cell-related miR-126, -92a/b; vascular smooth muscle cell-related miR-145; inflammation-related miR-16, -21, -125b, -146a/b, -147b, -150, -155; lipometabolism-related miR-27b, -122, -370) were evaluated by using real-time polymerase chain reaction. RESULTS: In patients with early onset coronary artery disease, plasma expressions of the lipometabolism-related miR-27b, miR-122; inflammation-related miR-125b, miR-146a/b, miR-147b, miR-150, miR-155; and VSMC-related miR-145 were significantly downregulated and endothelial cell-related miR-126 was significantly upregulated compared to age- and sexmatched healthy controls. Circulating microRNA profile of patients with early onset coronary artery disease was also different from that of older patients with late-onset coronary artery disease. Plasma levels of miR-21, miR-27b, miR-122, miR-125b, miR-146b, miR-147b, and miR-155 were lower and plasma levels of miR-16 and miR-92a were higher in patients with early onset coronary artery disease compared to older patients with late-onset coronary artery disease. CONCLUSION: MicroRNAs are promising biomarkers for early onset coronary artery disease.


Subject(s)
Coronary Artery Disease , MicroRNAs , Biomarkers , Humans , Inflammation , MicroRNAs/genetics , MicroRNAs/metabolism
17.
Front Microbiol ; 13: 880847, 2022.
Article in English | MEDLINE | ID: mdl-35794920

ABSTRACT

Transporter discovery and engineering play an important role in cell factory development. Decreasing the intracellular concentration of the product reduces product inhibition and/or toxicity. Lowering intracellular concentrations is especially beneficial for achieving a robust strain at high titers. However, the identification of transporters for xenobiotic chemicals in the host strain is challenging. Here we present a high-throughput workflow to discover Escherichia coli transporters responsible for the efflux of the inhibitory xenobiotic compound melatonin. We took advantage of the Keio collection and screened about 400 transporter knockouts in the presence of a high concentration of melatonin. We found five transporters that when knocked out showed decreased tolerance to melatonin, indicating they are exporters of melatonin. We overexpressed these five genes individually in the production strain and found that one of them, yhjV, encoding a transporter with unknown substrates, resulted in a 27% titer increase in cultivation mimicking fed-batch fermentation. This study demonstrates how microbial cell factories can be improved through transporter identification and engineering. Further, these results lay the foundation for the scale-up of melatonin production in E. coli.

19.
ACS Synth Biol ; 10(12): 3379-3395, 2021 12 17.
Article in English | MEDLINE | ID: mdl-34762392

ABSTRACT

Microbes are being engineered for an increasingly large and diverse set of applications. However, the designing of microbial genomes remains challenging due to the general complexity of biological systems. Adaptive Laboratory Evolution (ALE) leverages nature's problem-solving processes to generate optimized genotypes currently inaccessible to rational methods. The large amount of public ALE data now represents a new opportunity for data-driven strain design. This study describes how novel strain designs, or genome sequences not yet observed in ALE experiments or published designs, can be extracted from aggregated ALE data and demonstrates this by designing, building, and testing three novel Escherichia coli strains with fitnesses comparable to ALE mutants. These designs were achieved through a meta-analysis of aggregated ALE mutations data (63 Escherichia coli K-12 MG1655 based ALE experiments, described by 93 unique environmental conditions, 357 independent evolutions, and 13 957 observed mutations), which additionally revealed global ALE mutation trends that inform on ALE-derived strain design principles. Such informative trends anticipate ALE-derived strain designs as largely gene-centric, as opposed to noncoding, and composed of a relatively small number of beneficial variants (approximately 6). These results demonstrate how strain design efforts can be enhanced by the meta-analysis of aggregated ALE data.


Subject(s)
Escherichia coli K12 , Escherichia coli Proteins , Escherichia coli/genetics , Escherichia coli K12/genetics , Escherichia coli Proteins/genetics , Laboratories , Mutation/genetics
20.
Kardiol Pol ; 79(11): 1215-1222, 2021.
Article in English | MEDLINE | ID: mdl-34599498

ABSTRACT

BACKGROUND: Since its first introduction, the spectrum and frequency of use of transcatheter aortic valve implantation (TAVI) have increased throughout the world. Therefore, it is crucial to determine which patients are at high mortality risk with TAVI. The Intermountain Risk Score (IMRS) is a score calculated from laboratory parameters. This study aimed to determine the long-term mortality of TAVI patients using the IMRS and to compare it with traditional scoring systems. METHODS: The study included a total of 133 patients undergoing TAVI at our hospital from 2010 to 2019. Demographic data, co-morbid diseases, echocardiographic and laboratory parameters were collected retrospectively. The performance of IMRS was assessed as compared to the mortality determined in the overall patient population. RESULTS: During the follow-up, 54.9% of patients (60 patients) (Group 1) survived; the mortality in Group 2 (60 patients) was 45.1%. The survival period had a mean of 1433 (±124) days. The mean IMRS was 1.67 (0.7) in Group 1 and 2.33 (0.72) in Group 2 (P <0.001). In multivariable analyses, only high risk of IMRS (hazard ratio [HR], 3.430; 95% confidence interval [CI], 1.537-7.653; P = 0.003) and EuroSCORE II (HR, 1.141; 95% CI, 1.011-1.288; P = 0.03) independently predicted long-term mortality. CONCLUSIONS: From the evaluation of all laboratory and echocardiography parameters, long-term mortality (>30 days) following the TAVI procedure can be said to be higher in patients with a high IMRS. The data from this study can be considered of value in demonstrating the clinical significance of IMRS calculation before the TAVI procedure.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Retrospective Studies , Risk Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...