Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
2.
Gynecol Obstet Invest ; 83(4): 388-396, 2018.
Article in English | MEDLINE | ID: mdl-29791906

ABSTRACT

BACKGROUND/AIMS: The objective of this study was to compare the depth and width of thermal spread caused on rat uterine tissue after application of 3 different electrosurgical generators. METHODS: Alsa Excell 350 MCDSe (Unit A), Meditom DT-400P (Unit M), and ERBE Erbotom VIO 300 D (Unit E) electrosurgical units (ESUs) were used. The number of Wistar Hannover rats required to obtain valid results was 10. The primary objective of the study was to compare the 3 ESUs using the same instrument and the same waveform. The secondary objective of the study was to compare the differences between monopolar and bipolar systems of each ESU separately using the same waveform. RESULTS: The thermal spread caused by each ESU using monopolar instruments with continuous and interrupted waveforms was significantly different. Among the 3 devices, Unit A caused the largest thermal uterine tissue spread. On the other hand, Unit E caused the most superficial thermal tissue spread, and the smallest thermal spread among all ESUs. CONCLUSIONS: Surgeons should note that different ESUs used with the same power output might create different thermal effects especially in the monopolar configuration within the same waveform, for the same duration, and with the same instrument.


Subject(s)
Electrosurgery/instrumentation , Surgical Instruments/statistics & numerical data , Thermal Conductivity , Animals , Female , Rats , Rats, Wistar , Uterus/surgery
3.
Surg Endosc ; 29(8): 2305-13, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25414065

ABSTRACT

BACKGROUND: Two-dimensional (2D) view is known to cause practical difficulties for surgeons in conventional laparoscopy. Our goal was to evaluate whether the new-generation, Three-Dimensional Laparoscopic Vision System (3D LVS) provides greater benefit in terms of execution time and error number during the performance of surgical tasks. METHODS: This study tests the hypothesis that the use of the new generation 3D LVS can significantly improve technical ability on complex laparoscopic tasks in an experimental model. Twenty-four participants (8 experienced, 8 minimally experienced, and 8 inexperienced) were evaluated for 10 different tasks in terms of total execution time and error number. The 4-point lickert scale was used for subjective assessment of the two imaging modalities. RESULTS: All tasks were completed by all participants. Statistically significant difference was determined between 3D and 2D systems in the tasks of bead transfer and drop, suturing, and pick-and-place in the inexperienced group; in the task of passing through two circles with the needle in the minimally experienced group; and in the tasks of bead transfer and drop, suturing and passing through two circles with the needle in the experienced group. Three-dimensional imaging was preferred over 2D in 6 of the 10 subjective criteria questions on 4-point lickert scale. CONCLUSIONS: The majority of the tasks were completed in a shorter time using 3D LVS compared to 2D LVS. The subjective Likert-scale ratings from each group also demonstrated a clear preference for 3D LVS. New 3D LVS has the potential to improve the learning curve, and reduce the operating time and error rate during the performances of laparoscopic surgeons. Our results suggest that the new-generation 3D HD LVS will be helpful for surgeons in laparoscopy (Clinical Trial ID: NCT01799577, Protocol ID: BEHGynobs-4).


Subject(s)
Clinical Competence , Imaging, Three-Dimensional/methods , Laparoscopy/education , Adult , Depth Perception , Female , Humans , Learning Curve , Male , Middle Aged , Operative Time , Prospective Studies , Surgeons