Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Neuroradiology ; 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38951171

ABSTRACT

INTRODUCTION: The Derivo 2 Heal Embolization Device (D2HED) is a novel flow diverter (FD) providing a fibrin-/heparin-based surface coating aiming at lower thrombogenicity. We evaluate periprocedural aspects and preliminary aneurysm occlusion efficacy for intracranial aneurysm treatment. METHODS: Thirty-four D2HEDs deployments (34 aneurysms, 32 patients) between 04/2021 and 10/2023 were analyzed. All patients were under dual antiplatelet therapy (dAPT). Periprocedural details, adverse events, and follow-up (FU) imaging were reviewed by consultant-level neuroradiologists. Complication rates and aneurysm occlusion efficacy are compared with performance data of other FDs based on literature research. RESULTS: Each intervention succeeded in the deployment of one D2HED. Significant and/or increased intraaneurysmal contrast stagnation immediately after D2HED deployment was seen in 73.5% of cases according to O'Kelly-Marotta (OKM) grading scale. Clinically relevant early adverse events occurred in three patients: Among them two cases with fusiform aneurysms in the posterior circulation (ischemic events, early in-stent-thrombosis) and one patient (ischemic event) out of the majority of 31 treated internal carotid artery aneurysms (3,2%). Regarding mid-term FU (> 165 days), one aneurysm did not show progressive occlusion presumably caused by a prominent A1 segment arising from the terminal ICA aneurysm itself. Apart from that, mid-term complete / partial occlusion rates of 80% / 20% could be demonstrated. CONCLUSION: Our case series - although suffering from restricted sample size - suggests a potential effectiveness of D2HED in managing intracranial aneurysms. Further studies with larger samples are warranted to quantify long-term occlusion efficacy and the impact of antithrombogenic surface coating on the necessary (d)APT.

2.
Sci Rep ; 13(1): 7147, 2023 05 02.
Article in English | MEDLINE | ID: mdl-37130900

ABSTRACT

Developing new capabilities to predict the risk of intracranial aneurysm rupture and to improve treatment outcomes in the follow-up of endovascular repair is of tremendous medical and societal interest, both to support decision-making and assessment of treatment options by medical doctors, and to improve the life quality and expectancy of patients. This study aims at identifying and characterizing novel flow-deviator stent devices through a high-fidelity computational framework that combines state-of-the-art numerical methods to accurately describe the mechanical exchanges between the blood flow, the aneurysm, and the flow-deviator and deep reinforcement learning algorithms to identify a new stent concepts enabling patient-specific treatment via accurate adjustment of the functional parameters in the implanted state.


Subject(s)
Aneurysm, Ruptured , Endovascular Procedures , Intracranial Aneurysm , Humans , Intracranial Aneurysm/surgery , Stents , Treatment Outcome , Hemodynamics , Endovascular Procedures/methods
3.
AJNR Am J Neuroradiol ; 43(8): 1158-1163, 2022 08.
Article in English | MEDLINE | ID: mdl-35863779

ABSTRACT

BACKGROUND AND PURPOSE: Treatment of PICA aneurysms can be technically challenging by either surgical or endovascular means. Our aim was to report our preliminary experience with intrasaccular flow disruption using the Woven EndoBridge (WEB) for the treatment of proximal PICA aneurysms. MATERIALS AND METHODS: Sixteen PICA aneurysms treated with the WEB at 3 institutions were retrospectively reviewed. Baseline patient and aneurysm characteristics, procedural specifics, clinical outcomes, and angiographic results were evaluated. RESULTS: All aneurysms were located at the proximal, anteromedullary segment of the PICA. Seven aneurysms were ruptured. The median aneurysm size was 3.9 mm (range, 2-12 mm), and all aneurysms were wide-neck. WEB deployment failed in 1 case due to WEB protrusion in a small PICA aneurysm. Additional stent implantation was required for 2 aneurysms to improve intra-aneurysmal WEB positioning. One patient developed a partial posterior cerebral artery territory infarction with transient hemianopsia. Intraoperative rerupture of a ruptured aneurysm could be immediately stopped by WEB deployment due to intrasaccular stasis; however, it might have contributed to a slight disability of the patient. At last angiographic follow-up, 12/15 aneurysms (80%) were completely occluded and 3/15 (20%) had a neck remnant. CONCLUSIONS: The preliminary results indicate that WEB treatment of proximal PICA aneurysms is feasible with a reasonable safety and efficacy profile. The advantages of intrasaccular flow disruption include preservation of the PICA, durable aneurysm occlusion, and omission of antiplatelet therapy. The low-profile WEB 17 delivery system might enable navigation to distal PICA aneurysms, which needs to be addressed further.


Subject(s)
Aneurysm, Ruptured , Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Treatment Outcome , Retrospective Studies , Aneurysm, Ruptured/diagnostic imaging , Aneurysm, Ruptured/surgery , Embolization, Therapeutic/methods , Vertebral Artery , Endovascular Procedures/methods
4.
AJNR Am J Neuroradiol ; 41(9): 1652-1656, 2020 09.
Article in English | MEDLINE | ID: mdl-32732267

ABSTRACT

BACKGROUND AND PURPOSE: After endovascular treatment of intracranial aneurysms with the Woven EndoBridge (WEB) device, worsening of aneurysm occlusion or re-opening was reported to be possibly associated with WEB shape modification. This study analyzed quantitatively the WEB shape modification with time in association with anatomic results. MATERIALS AND METHODS: Thirty patients with 32 WEB-treated intracranial aneurysms fulfilled the inclusion criteria of cranial CT at baseline (day of intervention) and a follow-up CT at least >1 months' later (median follow-up time, 11.4 months; interquartile range, 6.5-21.5 months). Adequate occlusion was observed in 84.4%, and aneurysm remnant, in 15.6%. WEB shape modification was quantified by a semiautomated approach on CT scans. Time courses were evaluated graphically and analytically; association analyses were performed by linear mixed-effects regression models. RESULTS: In 29/32 WEB devices (90.6%), the reduction in height was found to be at least 5%. The decrease in height with time was significantly associated with the time interval in days since the intervention (P < .0001): A stronger decrease in WEB height was associated with a longer time since the intervention (median reduction in 1 year, 19.2%; range, 8.6%-52.3%). No significant association was found with the quality of aneurysm occlusion, device size, rupture status of the aneurysm, aneurysm location, and reintervention rate. CONCLUSIONS: Shape modification was common in WEB-treated intracranial aneurysms with a median height reduction of 19.2% in 1 year. The quality of aneurysm occlusion was not associated with WEB modification.


Subject(s)
Embolization, Therapeutic/instrumentation , Endovascular Procedures/instrumentation , Intracranial Aneurysm/therapy , Treatment Outcome , Adult , Aged , Female , Humans , Longitudinal Studies , Male , Middle Aged , Retrospective Studies
5.
Rofo ; 187(4): 269-75, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25594373

ABSTRACT

PURPOSE: The purpose of this clinical feasibility study was to evaluate the applicability of magnetic resonance imaging (MRI) for the assessment of apical periodontitis in direct comparison with cone beam CT (CBCT). MATERIALS AND METHODS: 19 consecutive patients (average age 43 ±â€Š13 years) with 34 lesions in total (13 molars, 14 premolars and 7 front teeth) were enrolled in this feasibility study. Periapical lesions were defined as periapical radiolucencies (CBCT) or structural changes in the spongy bone signal (MRI), which were connected with the apical part of a root and with at least twice the width of the periodontal ligament space. The location and dimension of the lesions were compared between MRI and CBCT. RESULTS: While mainly mineralized tissue components such as teeth and bone were visible with CBCT, complimentary information of the soft tissue components was assessable with MRI. The MRI images provided sufficient diagnostic detail for the assessment of the main structures of interest. Heterogeneous contrast was observed within the lesion, with often a clear enhancement close to the apical foramen and the periodontal gap.  No difference for lesion visibility was observed between MRI and CBCT. The lesion dimensions corresponded well, but were slightly but significantly overestimated with MRI. A heterogeneous lesion appearance was observed in several patients. Four patients presented with a well circumscribed hyperintense signal in the vicinity of the apical foramen. CONCLUSION: The MRI capability of soft tissue characterization may facilitate detailed analysis of periapical lesions. This clinical study confirms the applicability of multi-contrast MRI for the identification of periapical lesions. KEY POINTS: MRI can be applied for the identification of periapical lesions without ionizing radiation exposure. MRI might facilitate more detailed characterization of periapical lesions. MRI might provide more accurate lesion dimensions as X-ray-based methods.


Subject(s)
Cone-Beam Computed Tomography/methods , Image Enhancement/methods , Magnetic Resonance Imaging/methods , Periapical Periodontitis/diagnosis , Adult , Feasibility Studies , Female , Humans , Image Interpretation, Computer-Assisted/methods , Male , Middle Aged , Sensitivity and Specificity , Tooth Apex/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...