1.
Molecules ; 25(21)2020 Nov 06.
Article in English | MEDLINE | ID: mdl-33172179

ABSTRACT

Ionic liquids are increasingly used for their superior properties. Four water-immiscible ionic liquids (butyltriethylammonium bis(trifluoromethylsulfonyl)imide, octyltriethylammonium bis(trifluoromethylsulfonyl)imide, dodecyltriethylammonium bis(trifluoromethylsulfonyl)imide, butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide) and their water miscible precursors (bromides) were synthesized in a microwave reactor and by conventional heating. The best conditions for microwave-assisted synthesis concerning the yield and the purity of the product are proposed. The heating in the microwave reactor significantly shortened the reaction time. Biocide and ecotoxic effects of synthesized ionic liquids and their precursors were investigated. All tested compounds had at least a little effect on the growth or living of microorganisms (bacteria or mold). The precursor dodecyltriethylammonium bromide was found to be the strongest biocide, but posed a risk to the aquatic environment due to its relatively high EC50 value in the test with Vibrio fischeri. We assumed that apart from the alkyl chain length, the solubility in water, duration of action, or type of anion can influence the final biocide and ecotoxic effect.


Subject(s)
Anti-Bacterial Agents/pharmacology , Antifungal Agents/pharmacology , Ionic Liquids/chemical synthesis , Ionic Liquids/pharmacology , Aliivibrio fischeri/drug effects , Ammonium Compounds/chemistry , Anti-Bacterial Agents/chemical synthesis , Antifungal Agents/chemical synthesis , Antifungal Agents/chemistry , Drug Evaluation, Preclinical/methods , Ecotoxicology/methods , Imidazoles/chemistry , Microwaves , Quaternary Ammonium Compounds/chemical synthesis , Quaternary Ammonium Compounds/pharmacology
2.
Rev Sci Instrum ; 85(12): 126110, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25554346

ABSTRACT

We are reporting on the design, performance, and application results of a phase and frequency comparator based on the direct phase-time measurement using a high performance event timer. The advantages of this approach are the simple implementation, a broad frequency range, and the clear interpretation of the measured results. Primarily we analyzed the background instability of the instrument in a common-clock test when a 200 MHz clock signal was connected to both inputs and the noise bandwidth was kept at 5 Hz by a preprocessing of the measured data. The results show that the Allan deviation of the background instability follows 4 × 10(-14)/τ for a wide range of averaging intervals from 0.1 s up to 10(4) s. These results are better than background instability of commercially available state-of-the-art instruments based on the phase difference multiplication. Finally the instrument was used for comparison of two H-masers. This experiment proofed that one of possible applications is a comparison of low-noise highly stable frequency sources and measurement of their frequency stability in the time-domain. The noise background of the instrument was negligible for averaging intervals longer than 100 ms.

3.
Rev Sci Instrum ; 83(11): 116104, 2012 Nov.
Article in English | MEDLINE | ID: mdl-23206111

ABSTRACT

We have designed, constructed, and tested the overall performance of the electronic circuit for the two-way time transfer between two timing devices over modest distances with sub-picosecond precision and a systematic error of a few picoseconds. The concept of the electronic circuit enables to carry out time tagging of pulses of interest in parallel to the comparison of the time scales of these timing devices. The key timing parameters of the circuit are: temperature change of the delay is below 100 fs/K, timing stability time deviation better than 8 fs for averaging time from minutes to hours, sub-picosecond time transfer precision, and a few picoseconds time transfer accuracy.

4.
Rev Sci Instrum ; 80(7): 076102, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19655987

ABSTRACT

A transversal surface acoustic wave filter has been used as a time interpolator in a time interval measurement device. We are presenting the experiments and results of an analysis of the nonlinear effects in such a time interpolator. The analysis shows that the nonlinear distortion in the time interpolator circuits causes a deterministic measurement error which can be understood as the time interpolation nonlinearity. The dependence of this error on time of the measured events can be expressed as a sparse Fourier series thus it usually oscillates very quickly in comparison to the clock period. The theoretical model is in good agreement with experiments carried out on an experimental two-channel timing system. Using highly linear amplifiers in the time interpolator and adjusting the filter excitation level to the optimum, we have achieved the interpolation nonlinearity below 0.2 ps. The overall single-shot precision of the experimental timing device is 0.9 ps rms in each channel.

5.
Rev Sci Instrum ; 78(9): 094701, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17902964

ABSTRACT

This article deals with the time interval measurement device, which is based on a surface acoustic wave (SAW) filter as a time interpolator. The operating principle is based on the fact that a transversal SAW filter excited by a short pulse can generate a finite signal with highly suppressed spectra outside a narrow frequency band. If the responses to two excitations are sampled at clock ticks, they can be precisely reconstructed from a finite number of samples and then compared so as to determine the time interval between the two excitations. We have designed and constructed a two-channel time interval measurement device which allows independent timing of two events and evaluation of the time interval between them. The device has been constructed using commercially available components. The experimental results proved the concept. We have assessed the single-shot time interval measurement precision of 1.3 ps rms that corresponds to the time of arrival precision of 0.9 ps rms in each channel. The temperature drift of the measured time interval on temperature is lower than 0.5 ps/K, and the long term stability is better than +/-0.2 ps/h. These are to our knowledge the best values reported for the time interval measurement device. The results are in good agreement with the error budget based on the theoretical analysis.