Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Publication year range
1.
Eur Cardiol ; 18: e08, 2023.
Article in English | MEDLINE | ID: mdl-37377450

ABSTRACT

Cancer and cardiovascular disease are the two main causes of death worldwide in both men and women. In the past decades, survival rate in cancer patients has substantially improved due to new treatments and developments in radiation therapy (RT). In women, breast cancer (BC) is the leading cause of cancer death and thoracic RT is a main component of the treatment in many cases. Nevertheless, despite new techniques that limit the area receiving RT, cardiac damage is still an important concern in BC patients. In this review, the following aspects will be addressed: pathophysiology of postradiotherapy heart damage in women with BC; mechanisms, diagnosis and prevention/management of heart damage; and future areas of potential research for radiotherapy injury in women.

2.
Eur Heart J ; 43(26): 2496-2507, 2022 07 07.
Article in English | MEDLINE | ID: mdl-35139531

ABSTRACT

AIMS: To evaluate the impact of a simplified, rapid cardiovascular magnetic resonance (CMR) protocol embedded in care and supported by a partner education programme on the management of cardiomyopathy (CMP) in low- and middle-income countries (LMICs). METHODS AND RESULTS: Rapid CMR focused particularly on CMP was implemented in 11 centres, 7 cities, 5 countries, and 3 continents linked to training courses for local professionals. Patients were followed up for 24 months to assess impact. The rate of subsequent adoption was tracked. Five CMR conferences were delivered (920 attendees-potential referrers, radiographers, reporting cardiologists, or radiologists) and five new centres starting CMR. Six hundred and one patients were scanned. Cardiovascular magnetic resonance indications were 24% non-contrast T2* scans [myocardial iron overload (MIO)] and 72% suspected/known cardiomyopathies (including ischaemic and viability). Ninety-eighty per cent of studies were of diagnostic quality. The average scan time was 22 ± 6 min (contrast) and 12 ± 4 min (non-contrast), a potential cost/throughput reduction of between 30 and 60%. Cardiovascular magnetic resonance findings impacted management in 62%, including a new diagnosis in 22% and MIO detected in 30% of non-contrast scans. Nine centres continued using rapid CMR 2 years later (typically 1-2 days per week, 30 min slots). CONCLUSIONS: Rapid CMR of diagnostic quality can be delivered using available technology in LMICs. When embedded in care and a training programme, costs are lower, care is improved, and services can be sustained over time.


Subject(s)
Cardiomyopathies , Iron Overload , Cardiomyopathies/diagnostic imaging , Cytidine Monophosphate , Developing Countries , Humans , Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging, Cine/methods , Magnetic Resonance Spectroscopy
3.
Rev. cuba. inform. méd ; 13(1): e442, ene.-jun. 2021. tab, graf
Article in Spanish | LILACS, CUMED | ID: biblio-1251728

ABSTRACT

El Sistema de Información Hospitalaria XAVIA HIS desarrollado por el Centro de Informática Médica (CESIM) está compuesto por módulos que aseguran la informatización de los procesos de las áreas de la institución hospitalaria. En la actualidad la gestión de los principales medios de diagnóstico se realiza de forma dispersa en diferentes módulos o sistemas. En este trabajo se presenta el módulo de Medios de Diagnóstico, desarrollo que permite la gestión de informes de solicitudes y resultados de forma configurable, así como la planificación de horarios y gestión de citas. Se analizó el proceso de negocio asociado a la gestión de información de medios de diagnóstico, se realizó un estudio de sistemas existentes con propósitos similares y se evaluaron tecnologías para su implementación. Se utilizó AUP-UCI como metodología de desarrollo, Java como lenguaje de programación y otras tecnologías libres y multiplataforma. El patrón arquitectónico implementado fue modelo-vista-controlador. El módulo de Medios de Diagnóstico del sistema XAVIA HIS, permite el soporte de los procesos de atención al paciente y la integración de la información sobre los medios de diagnóstico, además fomenta un aumento en la calidad del servicio. El módulo facilita la configuración de aspectos de solicitud e informe de las pruebas diagnósticas y la planificación de horarios y citas(AU)


Hospital Information System XAVIA HIS developed by the Medical Informatics Center (CESIM) is made up of modules that ensure the computerization of hospital institution areas processes. Currently, the management of the main diagnostic means is realized in a dispersed way in different modules or systems. This paper presents the Diagnostic Means module, development that allows the requests and results reports management in a configurable way, as well as the schedules planning and appointments management. The business process associated with the diagnostic means information management was analyzed, an existing systems study with similar purposes was carried out, and technologies for their implementation were evaluated. AUP-UCI were used as development methodology, Java as programming language and other free and multiplatform technologies. The architectural pattern implemented was model-view-controller. The XAVIA HIS system Diagnostic Means module, allows the patient care processes support and integration of information regarding diagnostic means, also encourages an increase in the service quality. The module facilitates the request and report aspects configuration of the diagnostic tests and the schedules and appointments planning(AU)


Subject(s)
Humans , Male , Female , Hospital Information Systems/standards , Telemedicine , Diagnostic Techniques and Procedures , Electronic Health Records , Health Level Seven/standards
6.
J Med Primatol ; 39(3): 177-86, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20345770

ABSTRACT

BACKGROUND: The purpose of this study is to better characterize the hematological, biochemical, respiratory, cardiovascular and electroneurophysiological parameters in young adult Cercopithecus aethiops sabaeus of both sexes. The rhesus and cynomolgus monkeys are widely used as experimental primate models. However, only few articles have been published testing toxicological effects of pharmaceuticals on African green monkey. METHODS: The present study was carried out with the recompilation of all parameters recorded before the first drug administration in five sub-chronic or chronic toxicological studies performed on 66 Cercopithecus aethiops sabaeus, born in Cuba. RESULTS: This study provides hematological, biochemical, respiratory, cardiovascular and electroneurophysiological data for both choosing animals to be included into experiments and monitoring these parameters during the study. CONCLUSIONS: We conclude that this study provides valuable integrated data for determining the health status, including electroneurophysiological parameters, data not previously reported for this species, of the African green monkey.


Subject(s)
Chlorocebus aethiops/physiology , Disease Models, Animal , Animals , Drug Evaluation, Preclinical , Evoked Potentials , Female , Male , Toxicity Tests , Vital Signs
7.
Cancer Biol Ther ; 6(9): 1390-5, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17827980

ABSTRACT

Nimotuzumab (h-R3) is a humanized anti-epidermal growth factor receptor monoclonal antibody (mAb) registered for treating head and neck tumours. The present study was designed to evaluate the systemic and skin toxicity of chronic intravenous administration of the h-R3 in a relevant species demonstrated by comparing the h-R3 binding affinity constants (Kd) in microsomal placental fractions from Homo sapiens and Cercopithecus aethiops monkeys using an EGF-Receptor radioligand competition assay. The Kd obtained for Nimotuzumab were 9.1 x 10(-8) M for monkeys and 4.5 x 10(-8) M for humans. Monkeys (n = 18) were distributed into 3 groups with 3 animals of each sex in each group. Group I received saline; group II received 2.85 mg/kg of h-R3; and group III received 28.57 mg/kg of the h-R3, which represent 1 and 10 times the human dose, and they were weekly intravenously treated during 26 weeks. During the study there were no deaths. Electroneurophysiological, sanguine chemistry and haematological results did not evidence alterations. Areas of haematomas, probably related with the administration procedure, were observed at the administration zones of all animals. The electrocardiography study showed at the end of the study a slight increase in the cardiac frequency of four treated animals without other signs. Unexpectedly, skin biopsies and a detailed clinical inspection of the animals did not detect the presence of cutaneous rash or any other skin toxicity sign reported for the majority of the anti-EGF-R monoclonal antibodies. It is concluded that doses up to 28.5 mg/kg of h-R3, intravenously administered during 26 weeks to Cercopithecus aethiops monkeys, do not produce considerable toxic effects.


Subject(s)
Antibodies, Monoclonal/chemistry , Antineoplastic Agents/toxicity , ErbB Receptors/antagonists & inhibitors , Skin/drug effects , Animals , Antibodies, Monoclonal/adverse effects , Antibodies, Monoclonal/toxicity , Antibodies, Monoclonal, Humanized , Antineoplastic Agents/adverse effects , Binding, Competitive , Chlorocebus aethiops , Electrocardiography/methods , ErbB Receptors/metabolism , Evoked Potentials , Female , Infusions, Intravenous , Male , Skin/metabolism , Toxicity Tests
SELECTION OF CITATIONS
SEARCH DETAIL
...