1.
J Diabetes Sci Technol ; : 19322968241230106, 2024 Feb 16.
Article in English | MEDLINE | ID: mdl-38366626

ABSTRACT

BACKGROUND: Automated insulin delivery (AID) systems have shown to improve glycemic control in a range of populations and settings. At the start of this study, only one commercial AID system had entered the Austrian market (MiniMed 670G, Medtronic). However, there is an ever-growing community of people living with type 1 diabetes (PWT1D) using open-source (OS) AID systems. MATERIALS AND METHODS: A total of 144 PWT1D who used either the MiniMed 670G (670G) or OS-AID systems routinely for a period of at least three to a maximum of six months, between February 18, 2020 and January 15, 2023, were retrospectively analyzed (116 670G aged from 2.6 to 71.8 years and 28 OS-AID aged from 3.4 to 53.5 years). The goal is to evaluate and compare the quality of glycemic control of commercially available AID and OS-AID systems and to present all data by an in-depth descriptive analysis of the population. No statistical tests were performed. RESULTS: The PWT1D using OS-AID systems spent more time in range (TIR)70-180 mg/dL (81.7% vs 73.9%), less time above range (TAR)181-250 mg/dL (11.1% vs 19.6%), less TAR>250 mg/dL (2.5% vs 4.3%), and more time below range (TBR)54-69 mg/dL (2.2% vs 1.7%) than PWT1D using the 670G system. The TBR<54 mg/dL was comparable in both groups (0.3% vs 0.4%). In the OS-AID group, median glucose level and glycated hemoglobin (HbA1c) were lower than in the 670G system group (130 vs 150 mg/dL; 6.2% vs 7.0%). CONCLUSION: In conclusion, both groups were able to achieve satisfactory glycemic outcomes independent of age, gender, and diabetes duration. However, the PWT1D using OS-AID systems attained an even better glycemic control with no clinical safety concerns.

3.
PLoS One ; 17(4): e0267570, 2022.
Article in English | MEDLINE | ID: mdl-35482748

ABSTRACT

INTRODUCTION: Drug errors pose a major health hazard to a number of patient populations. However, patients with type 2 diabetes mellitus seem especially vulnerable to this risk as diabetes mellitus is usually concomitant with various comorbidities and polypharmacy, which present significant risk factors for the occurrence of drug errors. Despite this fact, there is little data on drug errors from patients' perspective. The present survey aimed to examine the viewpoints of patients with type 2 diabetes mellitus regarding their experiences with medication errors, the overall treatment satisfaction, and their perceptions on how a medication error was handled in daily hospital routine. MATERIALS AND METHODS: Inpatients at the Department of Endocrinology and Diabetology of the University Hospital of Graz were included in the survey. Out of 100 patients, one-half had insulin therapy before hospitalization while the other half had no insulin therapy prior to admission. After giving informed consent, patients filled out a questionnaire with 22 items. RESULTS: Independent of their preexisting therapy, 25% of patients already suffered at least one drug error, whereby prescribing a wrong dose seemed to be the most common type of error. Furthermore, 26% of patients in the non-insulin versus 50% in the insulin group (p = 0.084) were convinced that drug errors were addressed honestly by the medical staff, while 54% in the non-insulin versus 80% in the insulin-group (p = 0.061) assumed that adequate measures were taken to prevent drug errors. Finally, 9 out of 10 patients seemed satisfied with their treatment regardless of their diabetes therapy. DISCUSSION/CONCLUSION: The results of the survey clearly showed that patients experienced at least one medication error during hospitalization. However, these errors only rarely led to patient harm. The survey also revealed the value of an honest and respectful doctor-patient relationship regarding patient perception of medication errors and general complaints. Increasing patient awareness on the existing in-hospital error management systems could eliminate treatment-related concerns and create a climate of trust that is essential for effective treatment.


Subject(s)
Diabetes Mellitus, Type 2 , Diabetes Mellitus, Type 2/drug therapy , Humans , Insulin/therapeutic use , Insulin, Regular, Human , Medication Errors , Physician-Patient Relations
4.
Biosensors (Basel) ; 12(2)2022 Feb 09.
Article in English | MEDLINE | ID: mdl-35200366

ABSTRACT

The aim of this study was to evaluate the accuracy and usability of a novel continuous glucose monitoring (CGM) system designed for needle-free insertion and reduced environmental impact. We assessed the sensor performance of two GlucoMen® Day CGM systems worn simultaneously by eight participants with type 1 diabetes. Self-monitoring of blood glucose (SMBG) was performed regularly over 14 days at home. Participants underwent two standardized, 5-h meal challenges at the research center with frequent plasma glucose (PG) measurements using a laboratory reference (YSI) instrument. When comparing CGM to PG, the overall mean absolute relative difference (MARD) was 9.7 [2.6-14.6]%. The overall MARD for CGM vs. SMBG was 13.1 [3.5-18.6]%. The consensus error grid (CEG) analysis showed 98% of both CGM/PG and CGM/SMBG pairs in the clinically acceptable zones A and B. The analysis confirmed that GlucoMen® Day CGM meets the clinical requirements for state-of-the-art CGM. In addition, the needle-free insertion technology is well tolerated by users and reduces medical waste compared to conventional CGM systems.


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose/metabolism , Diabetes Mellitus, Type 1 , Blood Glucose/chemistry , Blood Glucose Self-Monitoring/instrumentation , Diabetes Mellitus, Type 1/blood , Humans , Pilot Projects , Reproducibility of Results , Technology
5.
Cardiovasc Diabetol ; 20(1): 89, 2021 04 24.
Article in English | MEDLINE | ID: mdl-33894772

ABSTRACT

BACKGROUND: The lipid-lowering and positive cardiovascular effect of proprotein convertase subtilisin kexin type 9 (PCSK9) inhibitors was shown in several studies, hence, they are more widely used in the lipid-lowering management of individuals with high cardiovascular risk. As real-world data are still scarce, specifically in patients with type 2 diabetes (T2D), the aim of this retrospective analysis was to investigate the efficacy of PCSK9 inhibitors in lowering low-density lipoprotein cholesterol (LDL-C) in an outpatient clinic of a tertiary care center in routine care. METHODS: A retrospective analysis of data extracted from the electronic patient record was performed. Patients who were routinely prescribed with PCSK9 inhibitor therapy (alirocumab or evolocumab) during the years 2016 and 2019 were included in the analysis. Characteristics of the patient population, the effects on LDL-C and HbA1c levels as well as subsequent cardiovascular events were assessed over an observation period of 18 months. RESULTS: We identified 237 patients treated with PCSK9 inhibitors between January 2016 and September 2019. Almost all patients (97.5%) received PCSK9 inhibitors for secondary prevention. 26.2% of the population had a concomitant diabetes diagnosis. Intolerance to statins (83.1%), ezetimibe (44.7%) or both agents (42.6%) was reported frequently. Three months after initiation of PCSK9 inhibitor therapy, 61.2% of the patients achieved LDL-C levels < 70 mg/dl, and 44.1% LDL-C levels < 55 mg/dl. The median LDL-C was lowered from 141 mg/dl at baseline, to 60 mg/dl after 3 months and 66 mg/dl after 12 months indicating a reduction of LDL-C as follows: 57.5% after 3 months and 53.6% after 12 months. After 3 months of observation, target achievement of LDL-C was higher in patients with T2D compared to non-diabetes patients; < 55 mg/dl: 51% vs. 41.5%; < 70 mg/dl 69.4 vs. 58.5%. After 12 months even more pronounced target LDL achievement in T2D was demonstrated < 55 mg/dl: 58.8% vs. 30.1%; < 70 mg/dl 70.6 vs. 49.6%. Patients with insufficiently controlled T2D (HbA1c > 54 mmol/mol) had a higher reduction in LDL-C but still were more likely to subsequent cardiovascular events. CONCLUSIONS: Significant reductions in LDL-C and a high percentage of patients achieving recommended treatment targets were observed. The percentage of patients with T2D meeting recommended LDL-C targets was higher than in those without T2D. Still some patients did not achieve LDL-C levels as recommended in current guidelines. Special attention to the characteristics of these patients is required in the future to enable achievement of treatment goals and avoid adverse cardiovascular outcomes.


Subject(s)
Anticholesteremic Agents/therapeutic use , Cardiovascular Diseases/prevention & control , Cholesterol, LDL/blood , Diabetes Mellitus, Type 2/drug therapy , Dyslipidemias/drug therapy , PCSK9 Inhibitors , Serine Proteinase Inhibitors/therapeutic use , Aged , Anticholesteremic Agents/adverse effects , Biomarkers/blood , Cardiovascular Diseases/blood , Cardiovascular Diseases/diagnosis , Diabetes Mellitus, Type 2/blood , Diabetes Mellitus, Type 2/diagnosis , Dyslipidemias/blood , Dyslipidemias/diagnosis , Female , Glycated Hemoglobin/metabolism , Heart Disease Risk Factors , Humans , Male , Middle Aged , Retrospective Studies , Risk Assessment , Serine Proteinase Inhibitors/adverse effects , Tertiary Care Centers , Time Factors , Treatment Outcome
6.
Diabetes Obes Metab ; 23(6): 1402-1408, 2021 06.
Article in English | MEDLINE | ID: mdl-33528887

ABSTRACT

Maintaining good glycaemic control with the same infusion set for longer than 3 days may improve the quality of life of insulin pump users. The aim of the current study was to assess the efficacy and safety of the novel, extended-wear infusion set over 7 days of wear in adults with type 1 diabetes. Sixteen participants completed three identical 8-hour euglycaemic clamp experiments on Days 1, 4 and 7 of infusion set wear. Between the experiments, the participants were discharged home for routine diabetes management while wearing the same extended-wear infusion set throughout the study. Time to reach the maximum glucose infusion rate (TGIRmax ) on Day 7 was reduced by 67% compared with Day 1 (p < .001). The corresponding area under the glucose infusion rate curve (AUCGIR ) was comparable for the first 2 h of the clamp (p = .891) but decreased by 28% over time (p < .008). While the extent of insulin absorption decreased with prolonged wear, it was accompanied by an increase in insulin absorption rate. The infusion set survival rate was 100% without leakages, occlusion alarms, severe hypoglycaemia or ketoacidosis. The extended-wear infusion set proved safe and effective during prolonged wear in real-life conditions.


Subject(s)
Diabetes Mellitus, Type 1 , Adult , Blood Glucose , Diabetes Mellitus, Type 1/drug therapy , Glucose Clamp Technique , Humans , Hypoglycemic Agents/therapeutic use , Insulin/therapeutic use , Insulin Infusion Systems , Quality of Life , Technology