1.
Acta Anaesthesiol Scand ; 59(6): 723-32, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25867049

ABSTRACT

BACKGROUND: Post-operative positive end-expiratory pressure (PEEP) setting to minimize the risk of ventilator-associated lung injury is still controversial. Assessment of regional ventilation distribution by electrical impedance tomography (EIT) might be superior as compared with global parameters. The aim of this prospective observational study was to compare global dynamic compliance (CRS ) with different EIT indices during a short clinical applicable descending PEEP trial. METHODS: Twenty mechanically ventilated patients after elective cardiac surgery received a standard recruitment manoeuvre (RM) following descending PEEP trial in steps of 2 cmH2 O from PEEP 14 cmH2 O to 6 cmH2 O. During baseline and all PEEP steps, CRS was assessed and regional ventilation distribution was measured by means of EIT. The individual 'best' PEEP values for the derived EIT indices and CRS were calculated and compared. RESULTS: The descending PEEP trial lasted less than 10 min. CRS increased after the RM and showed a maximum value at PEEP 8 cmH2 O. Ventilation distribution shifted more to dependent lung regions after RM and back to more non-dependent regions during the PEEP trial. Individual 'best' PEEP by CRS showed significantly lower values than 'best' PEEP by ventilation distribution measured with EIT indices. CONCLUSION: During a short descending PEEP trial at bedside, EIT is capable of following the status of regional ventilation distribution in ventilated patients. The 'best' PEEP value identified by individual maximum CRS was lower than optimal PEEP levels as determined by means of EIT indices. EIT could help setting PEEP in post-operative ventilated patients.


Subject(s)
Cardiac Surgical Procedures , Point-of-Care Systems , Positive-Pressure Respiration/methods , Postoperative Care/methods , Tomography/methods , Aged , Electric Impedance , Female , Humans , Male , Postoperative Period , Prospective Studies
2.
Int J Obstet Anesth ; 22(1): 67-71, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23122281

ABSTRACT

Amniotic fluid embolism is a rare peripartum complication with the sudden onset of haemodynamic instability, respiratory failure and coagulopathy during labour or soon after delivery. A 31-year-old woman with amniotic fluid embolism was treated with vasopressors, inotropes, intravenous fluid, tranexamic acid and ventilatory support. Assessment of respiratory impairment was made using conventional chest X-ray, computed tomography and electrical impedance tomography. The potential for electrical impedance tomography to improve monitoring and guide respiratory therapy is explored.


Subject(s)
Embolism, Amniotic Fluid/physiopathology , Positive-Pressure Respiration/methods , Postpartum Period , Respiratory Insufficiency/physiopathology , Respiratory Insufficiency/therapy , Tomography, X-Ray Computed/methods , Adult , Electric Impedance , Female , Follow-Up Studies , Humans , Pregnancy , Radiography, Thoracic/methods , Respiratory Insufficiency/complications
3.
Anaesthesist ; 61(11): 934-40, 2012 Nov.
Article in German | MEDLINE | ID: mdl-22965180

ABSTRACT

The determination of cerebral oxygen saturation (S(c)O(2)) by means of near-infrared spectroscopy allows non-invasive assessment of the cerebral oxygen delivery and demand ratio in the frontal cortex region. Studies in cardiac as well as non-cardiac patients have shown that maintaining S(c)O(2) in the preoperative range reduces the incidence of postoperative cognitive dysfunction and general morbidity; however, S(c)O(2) is not only reflective of cerebral but also of systemic oxygen balance, is inversely related to cardiopulmonary function and has prognostic relevance in cardiac surgery patients. This suggests that cerebral oximetry is not only useful for neurological but also for hemodynamic monitoring and preoperative risk stratification of cardiac surgery patients.


Subject(s)
Brain Chemistry , Cardiac Surgical Procedures , Oximetry/methods , Cerebrovascular Circulation/physiology , Cognition Disorders/etiology , Cognition Disorders/prevention & control , Cognition Disorders/psychology , Frontal Lobe/chemistry , Frontal Lobe/metabolism , Hemodynamics/physiology , Humans , Monitoring, Intraoperative , Postoperative Complications/prevention & control , Postoperative Complications/psychology , Preoperative Care , Prognosis , Risk Assessment , Spectroscopy, Near-Infrared
4.
Minerva Anestesiol ; 77(10): 952-8, 2011 10.
Article in English | MEDLINE | ID: mdl-21952594

ABSTRACT

BACKGROUND: In search of a non-invasive method for estimation of the oxygen balance this prospective study evaluates the relationship between regional cerebral oxygenation (rScO2) and mixed venous oxygen saturation in awake, spontaneously breathing patients after cardiac surgery. METHODS: After approval by the local ethical committee and written informed consent, 26 consecutive patients after cardiac surgery with cardiopulmonary bypass were enrolled. On intensive care unit (ICU), several hours after extubation, patients were connected to the INVOS 5100 cerebral monitor. Blood samples for determination of mixed venous oxygen saturation (SvO2) and central venous oxygen saturation (ScvO2) were drawn successively and rScO2 was documented. Patients were studied twice, breathing room air for the first measurement cycle, and breathing 4L/min supplemental oxygen by face mask, achieving a transcutaneous oxygen saturation above 98%, for a second measurement. RESULTS: Hemodynamic variables, hemoglobin and arterial carbon dioxide tension (PaCO2) remained stable between the two measurement cycles. Without oxygen, SvO2 and rScO2 showed a bias of -2.0%, limits of agreement (LOA) of -15.0 to 10.9% and a percentage error (PE) of 20.3%. SvO2 and ScvO2 showed a bias of -3.9%, LOA of -13.9 to 6.2% and PE 15.7%. With oxygen, the bias between SvO2 and rScO2 was -2.5%, LOA -14.2 to 9.2%, PE 17.2%. Between SvO2 and ScvO2 the bias was -4.1%, LOA -10.2 to 2.1%, PE 9.0%. CONCLUSION: The rScO2 measured by near infrared spectroscopy was sufficiently representing mixed venous oxygen saturation in awake, hemodynamically stable, spontaneously breathing patients after cardiac surgery. The agreement was comparable to the agreement between SvO2 and ScvO2 with smaller differences in the lower ranges of SvO2.


Subject(s)
Cardiac Surgical Procedures , Oxygen Consumption/physiology , Oxygen/blood , Blood Gas Analysis , Brain Chemistry/physiology , Cardiopulmonary Bypass , Female , Hemodynamics/physiology , Hemoglobins/metabolism , Humans , Hypoxia/therapy , Male , Monitoring, Intraoperative , Perioperative Care , Respiratory Mechanics/physiology
5.
Br J Anaesth ; 106(4): 475-81, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21205624

ABSTRACT

BACKGROUND: Pulse-contour analysis method (PCM) cardiac output (CO) monitors are increasingly used for CO monitoring during anaesthesia and in the critically ill. Very recently, several systems have been introduced that do not need calibration; among them the pressure recording analytical method (PRAM). Sparse data comparing the accuracy of the PRAM-CO with conventional thermodilution CO (ThD-CO) in cardiac surgery patients are available. METHODS: In this prospective comparison study, paired CO measurements with a pulmonary artery catheter and a PRAM monitoring set were obtained 20-30 min apart (t1, t2) in 23 extubated patients on the first postoperative day after cardiac surgery. Data were analysed by the Bland-Altman method. RESULTS: A total of 46 paired CO measurements (23 for each interval) were collected. The Bland-Altman analysis showed a mean difference (bias) of 0.0 litre min(-1) and limits of agreement (1.96 sd) of 4.53 to -4.54 litre min(-1) [upper 95% confidence interval (CI), 3.26-5.80; lower 95% CI, -5.8 to -3.27]. The percentage error (1.96 sd/mean of the reference method) was 87%. CONCLUSIONS: These results question the reliability of the PRAM technology for the determination of CO in postoperative cardiac surgery patients.


Subject(s)
Cardiac Output/physiology , Cardiac Surgical Procedures , Postoperative Care/methods , Aged , Aged, 80 and over , Blood Pressure/physiology , Cardiac Catheterization , Female , Humans , Male , Middle Aged , Monitoring, Physiologic/methods , Prospective Studies , Pulmonary Artery/physiopathology , Reproducibility of Results , Thermodilution/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...