Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Spat Vis ; 20(5): 415-36, 2007.
Article in English | MEDLINE | ID: mdl-17716526

ABSTRACT

PURPOSE: Does a physiologically plausible model of the retinal ganglion cell (RGC) receptive field (RF) predict the spatial tuning properties of the Hermann Grid Illusion (HGI)? METHODS: The spatial tuning of a single intersection HGI was measured psychophysically in normal observers using a nulling technique at different vertical grid line luminances. We used a model based upon a standard RGC RF, balanced to produce zero response under uniform illumination, to predict the response of the model cell to the equivalent range of stimulus conditions when placed in either the 'street' or the 'intersection' of a single element of a Hermann grid. We determined the equivalent of the nulling luminance required to balance these responses and minimise the HGI. RESULTS: The model and the psychophysical data demonstrated broad spatial tuning with similarly shaped tuning profiles and similar strengths of illusion. The line width at the peak of the model tuning function was around twice the model RGC RF centre size. Modelling the psychophysical functions gave RF centre sizes smaller than expected from human anatomical evidence but similar to that suggested by primate physiological evidence. In the model and psychophysically the strength of the illusion varied with the luminance of the vertical grid line when HGI strength was expressed as a Michelson nulling contrast, but this effect was smaller when HGI strength was expressed as a nulling luminance. CONCLUSIONS: The shape, width, height and position of the spatial tuning function of the HGI can be well modelled by a RGC RF based model. The broad tuning of these functions does not appear to require a broad range of different cell sizes either in the retina or later in the visual pathway.


Subject(s)
Illusions/physiology , Pattern Recognition, Visual/physiology , Retinal Ganglion Cells/physiology , Space Perception/physiology , Contrast Sensitivity/physiology , Humans , Models, Neurological , Photic Stimulation , Psychophysics/instrumentation
2.
Invest Ophthalmol Vis Sci ; 40(9): 1998-2009, 1999 Aug.
Article in English | MEDLINE | ID: mdl-10440254

ABSTRACT

PURPOSE: To determine the within-visit between-algorithm and the within-algorithm between-visit differences in sensitivity for the SITA Standard, SITA Fast, FASTPAC, and Full Threshold algorithms in stable primary open angle glaucoma. METHODS: One designated eye from each of 29 patients (age 67.3 +/- 10.2 years; mean +/- SD) experienced in automated perimetry was examined with the four algorithms on each of three visits, using the Humphrey Field Analyzer 750 and Program 30-2. RESULTS: The group mean Mean Sensitivity was 1.0 dB greater for SITA Standard than Full Threshold (P < 0.001), 0.7 dB greater for SITA Standard than FASTPAC (P < 0.001), 1.6 dB greater for SITA Fast than FASTPAC (P < 0.001), and 0.9 dB greater for SITA Fast than SITA Standard (P < 0.001). The higher pointwise sensitivity for SITA Fast compared to Full Threshold, FASTPAC, and SITA Standard increased with increase in defect depth. The examination duration for SITA Standard was 53% of that for Full Threshold and 50% shorter for SITA Fast compared to FASTPAC (P < 0.001), regardless of age (P = 0.932). The examination duration increased with increase in severity of field loss (P < 0.001), and this increase was proportionately greater for both SITA algorithms (P < 0.001), particularly SITA Fast. The Total and Pattern Deviation probability analyses of both SITA algorithms yielded a statistically greater defect than Full Threshold or FASTPAC (P < 0.001). The within-algorithm between-visit differences were similar between SITA Standard and Full Threshold and between SITA Fast and FASTPAC. CONCLUSIONS: Both SITA algorithms produce a marginally higher differential light sensitivity compared to existing algorithms but with a statistically deeper defect and a marked reduction in examination duration.


Subject(s)
Algorithms , Glaucoma, Open-Angle/diagnosis , Vision Disorders/diagnosis , Visual Field Tests/standards , Visual Fields , Adult , Aged , Cohort Studies , Female , Glaucoma, Open-Angle/physiopathology , Humans , Male , Middle Aged , Office Visits , Sensitivity and Specificity , Sensory Thresholds , Vision Disorders/physiopathology , Visual Fields/physiology
3.
Invest Ophthalmol Vis Sci ; 40(6): 1152-61, 1999 May.
Article in English | MEDLINE | ID: mdl-10235548

ABSTRACT

PURPOSE: To determine the between-algorithm differences in perimetric sensitivity for the Swedish Interactive Threshold algorithm (SITA) Standard, SITA Fast, FASTPAC, and Full Threshold algorithms; to determine the between-subject, between-algorithm differences in the magnitude of the normal variation in sensitivity. METHODS: The sample comprised 50 normal subjects (mean age, 52.9 +/- 18.5 years) experienced in automated perimetry. One randomly assigned eye was examined at three visits with Program 30-2 of the Humphrey Field Analyzer (HFA). The first visit was a familiarization session. A two-period crossover design with order randomization within visits was used over the second and third visits. SITA Standard, SITA Fast, and HFA 640 Full Threshold were administered during one visit. FASTPAC and HFA 750 Full Threshold were administered during the remaining visit. RESULTS: Group mean Mean Sensitivity was 0.8 dB higher for SITA Standard than for Full Threshold (P < 0.001) and 1.3 dB higher for SITA Fast than for Full Threshold (P < 0.001). A similar trend was found between SITA and FASTPAC. The group mean Mean Sensitivity for SITA Fast was 0.5 dB higher than for SITA Standard (P < 0.001). The pointwise between-algorithm difference in sensitivity was similar for all algorithms. The pointwise between-algorithm, between-subject variability was lower for SITA. The examination durations for SITA Fast and SITA Standard were half those for FASTPAC and Full Threshold; SITA Fast was 41% that of SITA Standard (P < 0.001). CONCLUSIONS: SITA produced marginally higher mean mean sensitivity compared with that of existing algorithms and markedly reduced examination duration. The reduced between-subject variability of SITA should result in narrower confidence limits for definition of normality.


Subject(s)
Algorithms , Visual Field Tests , Adult , Aged , Aged, 80 and over , Analysis of Variance , Cross-Over Studies , Female , Humans , Male , Middle Aged , Reference Values , Sensitivity and Specificity , Sensory Thresholds/physiology
4.
Invest Ophthalmol Vis Sci ; 39(1): 54-63, 1998 Jan.
Article in English | MEDLINE | ID: mdl-9430545

ABSTRACT

PURPOSE: To determine the intraindividual and interindividual characteristics of normal sensitivity derived by short-wavelength automated perimetry (SWAP) as a function of threshold algorithm. To determine also the influence of ocular media absorption on the magnitude of the interindividual variation in normal sensitivity, and hence the confidence limits, derived by SWAP. METHODS: The sample comprised 51 normal subjects, stratified for age by decade (mean age, 55.5 years; range, 24-83 years) and experienced in white-on-white (W-W) perimetry and SWAP. One randomly assigned eye of each subject was examined on three occasions with Program 30-2 of the 640 Humphrey Field Analyzer using the Full Threshold and FASTPAC strategies for SWAP and W-W perimetries. Ocular media absorption (OMA) was assessed by the difference in scotopic sensitivity to stimuli of 410 and 560 nm. RESULTS: The group mean examination time (P < 0.001) was greater for SWAP than for W-W perimetry for both the Full Threshold (15.0% longer) and FASTPAC strategies (16.8% longer). The gradient of the age-decline in Mean Sensitivity for SWAP was approximately 25% less steep when corrected for OMA than when uncorrected. The interindividual normal variability, expressed as the coefficient of variation, for SWAP without correction for OMA was 2.7 times greater (range 2.0-3.9), and with correction 1.9 times greater (range 1.4-2.9), than that for W-W perimetry. CONCLUSIONS: The increased interindividual normal variability of SWAP, exacerbated by the lack of correction for OMA, currently limits the utility of SWAP in that the reduction in sensitivity required to indicate abnormality was proportionately greater than for W-W perimetry.


Subject(s)
Sensory Thresholds/physiology , Visual Field Tests , Visual Fields/physiology , Absorption , Adult , Aged , Aged, 80 and over , Aging/physiology , Female , Humans , Light , Male , Middle Aged , Ocular Physiological Phenomena , Visual Field Tests/methods , Visual Field Tests/statistics & numerical data
SELECTION OF CITATIONS
SEARCH DETAIL
...